Polarization Calibration of a Microwave Polarimeter with Near-Infrared Up-Conversion for Optical Correlation and Detection
Open Access
Abstract
This paper presents a polarization calibration method applied to a microwave polarimeter demonstrator based on a near-infrared (NIR) frequency up-conversion stage that allows both optical correlation and signal detection at a wavelength of 1550 nm. The instrument was designed to measure the polarization of cosmic microwave background (CMB) radiation from the sky, obtaining the Stokes parameters of the incoming signal simultaneously, in a frequency range from 10 to 20 GHz. A linearly polarized input signal with a variable polarization angle is used as excitation in the polarimeter calibration setup mounted in the laboratory. The polarimeter systematic errors can be corrected with the proposed calibration procedure, achieving high levels of polarization efficiency (low polarization percentage errors) and low polarization angle errors. The calibration method is based on the fitting of polarization errors by means of sinusoidal functions composed of additive or multiplicative terms. The accuracy of the fitting increases with the number of terms in such a way that the typical error levels required in low-frequency CMB experiments can be achieved with only a few terms in the fitting functions. On the other hand, assuming that the calibration signal is known with the required accuracy, additional terms can be calculated to reach the error levels needed in ultrasensitive B-mode polarization CMB experiments.Keywords
All Related Versions
Funding Information
- Spanish Agencia Estatal de Investigación (AEI, MICIU) (ESP2017-92135-EXP, ESP2017-83921-C2-1-R, AYA2017-90675-REDC, PID2019-110610RB-C21/AEI/10.13039/501100011033, MDM-2017-0765)
- EU FEDER funds (ESP2017-92135-EXP, ESP2017-83921-C2-1-R, AYA2017-90675-REDC, PID2019-110610RB-C21/AEI/10.13039/501100011033, MDM-2017-0765)
- Unidad de Excelencia María de Maeztu (ESP2017-92135-EXP, ESP2017-83921-C2-1-R, AYA2017-90675-REDC, PID2019-110610RB-C21/AEI/10.13039/501100011033, MDM-2017-0765)
This publication has 33 references indexed in Scilit:
- Detection of-Mode Polarization in the Cosmic Microwave Background with Data from the South Pole TelescopePhysical Review Letters, 2013
- Self-calibration: an efficient method to control systematic effects in bolometric interferometryAstronomy & Astrophysics, 2013
- Calibration of Correlation Radiometers Using Pseudo-Random Noise SignalsSensors, 2009
- Systematic errors in cosmic microwave background polarization measurementsMonthly Notices of the Royal Astronomical Society, 2007
- Instrument, method, brightness, and polarization maps from the 2003 flight of BOOMERanGAstronomy & Astrophysics, 2006
- MAXIMA: A balloon-borne cosmic microwave background anisotropy experimentReview of Scientific Instruments, 2006
- Degree Angular Scale Interferometer 3 Year Cosmic Microwave Background Polarization ResultsThe Astrophysical Journal, 2005
- Four-Year [ITAL]COBE[/ITAL] DMR Cosmic Microwave Background Observations: Maps and Basic ResultsThe Astrophysical Journal, 1996
- A Measurement of Excess Antenna Temperature at 4080 Mc/s.The Astrophysical Journal, 1965
- The Origin of Chemical ElementsPhysical Review B, 1948