Latest Publications

  • Open Access

    From Ground to Orbit: Adapting CMB Calibration Technology for Space

    by Irene Sánchez-Ramos, Francisco Javier Casas, Javier Cubas, Guillermo Pascual-Cisneros, Laura Castelló, Enrique Martínez-González, Rita Belén Barreiro, Patricio Vielva

    The Cosmic Microwave Background (CMB) carries crucial information about the origin and evolution of the Universe, with its polarization patterns providing potential evidence of primordial gravitational waves. Achieving the precision required for these measurements demands highly accurate calibration methods. This study presents the development of a reference signal source to be integrated as the payload of LEO-CalSat, a Low-Earth Orbit satellite designed to serve as an artificial, far-field calibration tool for ground-based CMB polarization experiments. The system aims both to validate the technological readiness of a compact calibration payload for future L2 missions and to provide reference signals in the W-band (75–110 GHz) for current observatories. The calibration source, integrated within the volume of a CubeSat’s 2 U, was designed to balance miniaturization with performance, incorporating key components such as a frequency multiplier with a Voltage-Controlled Oscillator, horn antenna, and polarizer. Laboratory tests demonstrated fully polarized emission with output powers up to 6 dBm and a signal-to-noise ratio of approximately 30 dB, confirming the feasibility of precise polarization calibration. The reduced mass and power consumption (1 kg, 9 W) ensure compatibility with CubeSat constraints. The results validate the core concept and readiness of LEO-CalSat for space operation, representing a significant step toward establishing standardized, space-based calibration for future CMB missions and advancing precision cosmology.

  • Open Access

    QUIJOTE-TFGI polarization calibration

    by Alessandro Fasano, Mateo Fernández-Torreiro, Guillermo Pascual-Cisneros, Roger John Hoyland, Francisco Javier Casas-Reinares, Ricardo Tanausú Génova-Santos, Michael William Peel, Rafael Rebolo-López, José Alberto Rubiño-Martín

    Context . Polarization measurements in the 30–40 GHz range are essential to improving our understanding of Galactic synchrotron radiation and potential anomalous microwave emissions, and obtaining such measurements will ultimately aid in detecting primordial B modes. To achieve this aim, it is crucial to achieve unprecedented performance in instrumentation. Thus, accurately calibrating instrument responses and the polarization angle represents an essential step in state-of-the-art setups. The modeling and mitigation of systematic effects are also critical in this context. Aims . Our objective is to characterize the QUIJOTE Thirty and Forty GHz instrument (TFGI), calibrate it with a reference calibration signal on the ground, compare our results with on-sky calibration based on bright sources, and study the stability of the calibration parameters over time. Methods . First, from the ground, we fit the data using a reference calibration signal (a diode) introduced to resolve degeneracies among the various instrument angles. Finally, we utilized on-sky observations of Tau A and the Moon to validate the results. Results . By creating calibration datasets obtained with the reference diode, we evaluated the data quality and quantified phase switch errors to account for the fine polarization response. We also utilized Tau A and Moon observations to calibrate the system’s response and stability over time. In addition, we calculated the refraction index of the Moon to be n Moon = 1.209 ± 0.007 (stat) ± 0.009 (sys) at 31 GHz under smooth-surface assumption. Conclusions . The results from fitting the instrument phase-switch error angle align with 0 deg at 2 σ precision, indicating that no further correction is required within a few percent precision. The calibrations with astrophysical sources (Tau A and the Moon) yielded consistent results that constrain the polarization angle and responsivity. The polarization efficiency aligns well with ground measurements and the Tau A characterization, whereas the Moon-based calibration is more affected by systematics. We found hints of responsivity variations over time, although the relative responsivity between channels was found to remain stable. We conclude that installing a live calibrator in the future will enhance the performance of TFGI by continuously monitoring responsivity and in turn improving the mitigation of systematic effects.


  • Open Access

    Photonic Integrated Circuits for Microwave Astronomy

    by Guillermo Pascual-Cisneros, Francisco J. Casas, Patricio Vielva

    One of the main objectives of cosmology is the measurement of the Cosmic Microwave Background (CMB) polarization and, in particular, the so-called B-modes, which could demonstrate the existence of the primordial gravitational waves generated at the early stages of the Universe. For this reason, a new integrated version of the heterodyne polarimeter photonic part shown on a previously proposed scheme that can be used in both direct imaging and interferometric instruments is presented. We have tested its properties using specific commercial software, obtaining promising results. Working as a direct imaging instrument, it is shown that the proposed polarimeter can provide sufficiently low polarization angle and polarization efficiency systematic errors, which are considered acceptable for current ground-based CMB polarization experiments dedicated to the characterization of the foreground signals affecting the lowest part of the frequency spectrum.


  • Open Access

    Mach–Zehnder Modulators for Microwave Polarization Measurement in Astronomy Applications

    by Francisco J. Casas, Guillermo Pascual-Cisneros

    This paper presents a study of the performances of different Mach–Zehnder modulation technologies with applications in microwave polarimeters based on a near-infrared (NIR) frequency up-conversion stage, allowing for optical correlation and signal detection at a wavelength of 1550 nm. Commercial Mach–Zehnder modulators (MZMs) are traditionally implemented using LiNbO3 technology, which does not enable integration for the fabrication of MZMs. In this work, we propose the use of an alternative technology based on InP, which allows for integration in the fabrication process. In this way, it is possible to obtain advantages in terms of bandwidth, cost, and size reductions, which yield results that are very interesting for wide-band applications such as microwave instrumentation for the study of the cosmic microwave background (CMB). Here, we describe and compare the modulation performances of different MZMs, with one commercial unit presenting a higher bandwidth than those in previous works, and another three InP integrated units provided by the Fraunhofer Institute for Telecommunications, Heinrich-Hertz-Institute (HHI). Then, these modulators were coupled to a microwave polarimeter demonstrator, which has also been presented previously, to compare the polarization measurement performances of each of the MZMs.


  • Open Access

    Optimization of a Microwave Polarimeter for Astronomy with Optical Correlation and Detection

    by Guillermo Pascual-Cisneros, Francisco J. Casas, Patricio Vielva

    Cosmic Microwave Background (CMB) B-modes detection is the main focus of future CMB experiments because of the valuable information it contains, particularly to probe the physics of the very early universe. For this reason, we have developed an optimized polarimeter demonstrator sensitive to the 10–20 GHz band in which the signal received by each antenna is modulated into a Near Infrared (NIR) laser by a Mach–Zehnder modulator. Then, these modulated signals are optically correlated and detected using photonic back-end modules consisting of voltage-controlled phase shifters, a 90-degree optical hybrid, a pair of lenses, and an NIR camera. During laboratory tests, a 1/f-like noise signal related to the low phase stability of the demonstrator has been found experimentally. To solve this issue, we have developed a calibration method that allows us to remove this noise in an actual experiment, until obtaining the required accuracy level in the measurement of polarization.


  • Open Access

    Polarization Calibration of a Microwave Polarimeter with Near-Infrared Up-Conversion for Optical Correlation and Detection

    by Francisco J. Casas, Patricio Vielva, R. Belen Barreiro, Enrique Martínez-González, G. Pascual-Cisneros

    This paper presents a polarization calibration method applied to a microwave polarimeter demonstrator based on a near-infrared (NIR) frequency up-conversion stage that allows both optical correlation and signal detection at a wavelength of 1550 nm. The instrument was designed to measure the polarization of cosmic microwave background (CMB) radiation from the sky, obtaining the Stokes parameters of the incoming signal simultaneously, in a frequency range from 10 to 20 GHz. A linearly polarized input signal with a variable polarization angle is used as excitation in the polarimeter calibration setup mounted in the laboratory. The polarimeter systematic errors can be corrected with the proposed calibration procedure, achieving high levels of polarization efficiency (low polarization percentage errors) and low polarization angle errors. The calibration method is based on the fitting of polarization errors by means of sinusoidal functions composed of additive or multiplicative terms. The accuracy of the fitting increases with the number of terms in such a way that the typical error levels required in low-frequency CMB experiments can be achieved with only a few terms in the fitting functions. On the other hand, assuming that the calibration signal is known with the required accuracy, additional terms can be calculated to reach the error levels needed in ultrasensitive B-mode polarization CMB experiments.