Compensating for beam modulation due to microscopic lung heterogeneities in carbon ion therapy treatment planning
Open Access
- 20 October 2021
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 48 (12) , 8052-8061
Abstract
Purpose: To predict and mitigate for the degradation in physical and biologically effective dose distributions of particle beams caused by microscopic heterogeneities in lung tissue.Materials and Methods: The TRiP98 treatment planning system was adapted to account for the beam‐modulating effect of heterogeneous lung tissue in physical and biological inverse treatment planning. The implementation employs an analytical model that derives the degradation from the established “modulation power” parameter and the total water‐equivalent thickness of lung parenchyma traversed by the beam. Beam modulation was reproduced through an on‐the‐fly convolution of the reference Bragg curve with Gaussian kernels depending on the modulation power of lung tissue (upstream). For biological doses, the degradation was determined by modulating dose‐averaged , , and LET distributions. Carbon SOBP measurements behind lung substitute material were performed to validate the code. The implementation was then applied to a phantom and patient case.Results: Experimental results show the passage through a 20‐cm Gammex LN300 slab led to a decrease in target coverage and broadening of the SOBP distal fall‐off. However, dose coverage was regained through optimization. A good agreement between calculated and measured SOBPs was also found. In addition, a patient case study revealed a 3.2% decrease in D from degradation ( = 450 m), which was reduced to a 0.4% difference after optimization. Furthermore, widening of the RBE distribution beyond the target distal edge was observed. This implies an increased degradation in the biological dose, which could be harmful to healthy tissues distal to the target.Conclusions: This is the first implementation capable of compensating for lung dose perturbations, which is more effective than margin extensions. A larger patient study is needed to examine the observed modulation in the RBE distribution and judge the clinical relevance also in IMPT, where margins might prove insufficient to recover target coverage.Keywords
This publication has 20 references indexed in Scilit:
- RBE of ion beams in hypofractionated radiotherapy (SBRT)Physica Medica, 2014
- Motion mitigation in intensity modulated particle therapy by internal target volumes covering range changesMedical Physics, 2012
- Uncertainties in planned dose due to the limited voxel size of the planning CT when treating lung tumors with proton therapyPhysics in Medicine & Biology, 2011
- Quantification of the Relative Biological Effectiveness for Ion Beam Radiotherapy: Direct Experimental Comparison of Proton and Carbon Ion Beams and a Novel Approach for Treatment PlanningInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Heavy-ion tumor therapy: Physical and radiobiological benefitsReviews of Modern Physics, 2010
- Density heterogeneities and the influence of multiple Coulomb and nuclear scatterings on the Bragg peak distal edge of proton therapy beamsPhysics in Medicine & Biology, 2008
- Quantifying lateral tissue heterogeneities in hadron therapyMedical Physics, 2007
- Rapid calculation of biological effects in ion radiotherapyPhysics in Medicine & Biology, 2006
- Errors and margins in radiotherapySeminars in Radiation Oncology, 2004
- Degradation of the Bragg peak due to inhomogeneitiesPhysics in Medicine & Biology, 1986