Developing a Structurally Modified Mechanical Lumped Model of the Human Tibia and Shin Guard Using Modal Analysis
Authors:
- 22 December 2024
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (4) , 845-854
Abstract
Shins are one of the most vulnerable bones in human body. Shin guards are evaluated by their effectiveness in reducing the force applied to the bone. In this study, a structural modified mechanical lumped model of the shin guard was developed to provide maximum force distribution using physical parameter change modification technique and genetic algorithm. Modal analysis and finite element methods were used to determine the dynamic behavior of the system in the frequency range of 0–3000 Hz. In this research, FE results had an encouraging agreement with those in experimental test with a Mean Absolute Error (MAE) found as 34.94. The results proposed two design zones to select the stiffness of the shin guard. The stiffnesses K1 and K2 were selected between the values in the design zones. For situation, K1 = 7.9 × 105 N/m and K2 = 6.3 × 105 N/m, the distribution parameter was equal to 76% and f1 = 1.87F, f2 = 0.71F f3 = 1.81F, meaning the force was effectively distributed.Keywords
This publication has 18 references indexed in Scilit:
- High correlation between mechanical properties and bone mineral parameters in embalmed femurs after long-term storageClinical Biomechanics, 2018
- Material model of pelvic bone based on modal analysis: a study on the composite boneBiomechanics and Modeling in Mechanobiology, 2016
- Validation of density–elasticity relationships for finite element modeling of human pelvic bone by modal analysisJournal of Biomechanics, 2013
- Global stiffness and natural frequency analysis of distributed compliant mechanisms with embedded actuators with a general-purpose finite element systemThe International Journal of Advanced Manufacturing Technology, 2012
- Vibration measurements predict the mechanical properties of human tibiaClinical Biomechanics, 2010
- The effect of the density–modulus relationship selected to apply material properties in a finite element model of long boneJournal of Biomechanics, 2008
- Development of a three-dimensional finite element model of a human tibia using experimental modal analysisJournal of Biomechanics, 1991
- Modelling human tibia structural vibrationsJournal of Biomechanics, 1990
- Vibrational characteristics of the embalmed human femurJournal of Sound and Vibration, 1981
- Natural frequency analysis of a human tibiaJournal of Biomechanics, 1980