YOYukihisa Ogawa

Yukihisa Ogawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yukihisa Ogawa has a total of 74 co-authors. Here are the top co-authors by number of shared publications:

  • Hiroshi Nishimaki

    Department of Cardiovascular Surgery, St. Marianna University School of Medicine

    11 shared publications
  • Kiyoshi Chiba

    Department of Cardiovascular Surgery, St. Marianna University School of Medicine

    9 shared publications
  • Takeshi Miyairi

    Department of Cardiovascular Surgery, St. Marianna University School of Medicine

    9 shared publications
  • Hidefumi Mimura

    Department of Radiology, St. Marianna University School of Medicine

    5 shared publications
  • Yasuo Nakajima

    Department of Radiology, St. Marianna University, School of Medicine

    5 shared publications
  • Yuka Sakurai

    Department of Cardiovascular Surgery, St. Marianna University, School of Medicine

    5 shared publications

Latest Publications

  • Open Access

    Black candy-plug technique for a large false lumen in a patient with complicated type B aortic dissection

    by Yukihisa Ogawa, Shunsuke Kamei, Hidekazu Furuya, Ryuichi Tamimoto, Akiyoshi Yamamoto, Hiroyuki Nishi

  • Open Access

    Coil Embolization of Recurrent Internal Iliac Artery Aneurysm via the Superior Gluteal Artery

    by Takuro Fukumoto, Yukihisa Ogawa, Kiyoshi Chiba, Shintaro Nawata, Shojiro Morikawa, Takeshi Miyairi, Hidefumi Mimura, Hiroshi Nishimaki

    Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.


  • Outcomes of the Gore Excluder Iliac Branch Endoprosthesis for Japanese Patients With Aortoiliac Aneurysms: A Study Based on J-Preserve Registry

    by Yukihisa Ogawa, Naoki Fujimura, Masato Yamaguchi, Hiroshi Banno, Tadashi Furuyama, Terutoshi Yamaoka, Makoto Sumi, Tetsuya Fukuda, Noriyasu Morikage, Etsuji Sohgawa, et al.

    Purpose: To evaluate the clinical utility of the Gore Excluder iliac branch endoprosthesis (IBE) for Japanese patients with aortoiliac aneurysms. Materials and Methods: This was a multicenter retrospective cohort study (J-Preserve Registry). Patients undergoing endovascular aortic repair using the Gore Excluder IBE for aortoiliac aneurysms between August 2017 and June 2020 were enrolled. Data pertaining to the baseline and anatomical characteristics, technical details, and clinical outcomes were collected from each institution. The primary endpoints were technical success, IBE-related complications, and reinterventions. Secondary endpoints were mortality, aneurysm size change, and reintervention during follow-up. Technical success was defined as accurate deployment of the IBE without type Ib, Ic, or III endoleaks on the IBE sides on completion angiography. A change in aneurysm size of 5 mm or more was taken to be a significant change. Results: We included 141 patients with 151 IBE implantations. Sixty-five IBE implantations (43.0%) had at least one instruction for use violation. Twenty-two patients (15.6%) required internal iliac artery (IIA) embolization for external iliac artery extension on the contralateral side. Of 151 IBE implantations, 19 exhibited IIA branch landing zones due to IIA aneurysms. Mean maximum and proximal common iliac artery (CIA) diameters were 32.9±9.9 mm and 20.5±6.9 mm, respectively. The mean CIA length was 59.1±17.1 mm. The IIA landing diameter and length were 9.0±2.3 mm and 33.8±14.6 mm. The overall technical success rate was 96.7%. There were no significant differences in IBE-related complications (2.3% vs 5.3%, p=0.86) or IBE-related reinterventions (1.5% vs 5.3%, p=0.33) between the IIA trunk and IIA branch landing groups. The mean follow-up period was 635±341 days. The all-cause mortality rate was 5.0%. There were no aneurysm-related deaths or ruptures during the follow-up. Most patients (95.7%) had sac stability or shrinkage. Conclusion: The Gore Excluder IBE was safe and effective for Japanese patients in the midterm. Extending the IIA device into the distal branches of the IIA was acceptable, which may permit extending indications for endovascular aortic aneurysm repair of aortoiliac aneurysms to more complex lesions. Clinical Impact: This study suggests clinical benefits of the Gore Excluder IBE for Japanese patients, despite 43% of the IBE implantations having at least one IFU violation.


  • A feasibility study of percutaneous transhepatic gallbladder filling (PTGBF) in a swine model

    by Yukihisa Ogawa, Manabu Kubota, Masayuki Takagi, Hidefumi Mimura

    Background: Treatments for acute cholecystitis include cholecystectomy and percutaneous drainage. However, some patients are at high risk for surgery, and prolonged drainage can decrease their quality of life. Purpose: To determine the feasibility of percutaneous transhepatic gallbladder filling (PTGBF) with n-butyl-cyanoacrylate (NBCA) in a swine model. Material and methods: After the induction of general anesthesia, percutaneous transhepatic gallbladder puncture to a pig weighing 49 kg using a 20-G-percutaneous transhepatic cholangio drain (PTCD) needle was performed under ultrasound guidance. A 2.1 F-microcatheter was inserted through the outer PTCD needle, then the cystic duct was coil-embolized. The microcatheter was removed, the gallbladder was filled with 25% NBCA-Lipiodol, then the PTCD needle was withdrawn without complications. Blood was sampled and CT images were acquired from the pig immediately after the procedure and on postoperative day 7. The pig was euthanized on postoperative day 7 and the gallbladder was evaluated by microscopy. Results: Vital signs were stable, and the CT images showed that the gallbladder contained NBCA-Lipiodol without complications such as leakage. Hepatobiliary enzymes were not elevated. Histological findings demonstrated loss of most mucosa with partial regeneration, and lymphocytic infiltration. The muscle layer was intact. Conclusion: This technique might offer a feasible alternative to surgery for high-risk patients with acute cholecystitis, but further studies are needed to determine the safety and long-term effects of this procedure.


  • Early Clinical Outcomes of the Active Seal Technology of the AFX Endovascular Aortic Aneurysm System With the VELA Cuff for Patients With a Conical Proximal Neck

    by Naoki Fujimura, Hideaki Obara, Takaaki Nagano, Yukihisa Ogawa, Taira Kobayashi, Takahiro Ohmine, Yasuhiro Ozeki, Shoji Sakaguchi, Terutoshi Yamaoka, Hideki Ueda, et al.

    Purpose: To evaluate the efficacy of the Active Seal technology employed in the AFX endovascular aortic aneurysm system (AFX), during endovascular aneurysm repair (EVAR) in patients with abdominal aortic aneurysms (AAAs) having a conical proximal neck. Materials and Methods: A retrospective analysis of the EVAR for AAA with a conical proximal neck using the AFX was performed at 17 Japanese hospitals between January 2016 and August 2020. The conical proximal neck was defined as a cone-shaped proximal neck, with more than 10% diameter increase within a 15 mm length at the proximal landing zone. All anatomical analyses were performed in the core laboratory, and cases with parallel walls within the proximal neck adequate for the landing zone were excluded from the study. Results: This study included 53 patients, but only 39 patients (mean age, 76.6 ± 6.7 years; 87.0% males; mean aneurysm diameter, 52.0 ± 8.0 mm) were analyzed after being characterized as having a pure conical neck by the core laboratory. The mean proximal neck diameters at the lower renal artery and proximal edge of the aneurysm were 20.0 ± 2.9 mm and 27.5 ± 4.9 mm, respectively. The mean proximal neck length was 21.5 ± 6.0 mm. Instructions for use violations other than the conical neck were observed in 15 patients (38.5%). The VELA cuff was used in all cases; however, additional proximal cuff was required in 9 more cases (23.1%). The Active Seal technology was able to significantly extend the proximal sealing zone from 21.5 ± 6.0 to 26.0 ± 12.2 mm ( p = .047). Thirty-six patients completed the 12-month follow-up (one patient was lost to follow-up, and 2 patients died from causes unrelated to the aneurysm), and there were no type-1a and 3 endoleaks with only one reintervention (2.6%) related to type 1b endoleak in the 12-month period. Furthermore, there was no significant enlargement of the proximal neck diameter at 12 months (at 1 month: 20.6 ± 3.4 mm and at 12 months: 21.3 ± 3.8 mm; p = .420). Conclusion: The Active Seal technology of the AFX significantly extended the proximal seal zone and no type-1a endoleak and proximal neck dilation was observed in patients with conical proximal neck at 12 months.


  • Open Access

    A Technical Improvement for Percutaneous Puncture of the Intervertebral disc by Passing Lateral to the Superior Articular Process Using the Isocenter Puncture Method

    by Shingo Hamaguchi, Shinji Wada, Yukihisa Ogawa, Kazuki Hashimoto, Hidefumi Mimura

    Purpose: Percutaneous intervertebral disc puncture is useful in various situations. The isocenter puncture method enables easy, accurate, and safe punctures under fluoroscopic guidance. Herein, we present a clinical application of this technique that improves upon percutaneous puncture of intervertebral discs. Material and Methods: We performed percutaneous punctures of intervertebral discs slightly lateral to the superior articular process using the isocenter puncture method in 19 cases (10 men, 9 women; mean age, 64.5 years; range, 23-87 years). We assessed the technical success rate, procedure time, and complications. Results: We achieved successful punctures in all cases, with a median puncture time of 14.5 min (mean, 18.7 ± 11.3 min; range, 8-49 min). No patients complained of complications that were permanent or required treatment. Conclusions: Improved puncture of intervertebral discs seems to be possible using the isocenter puncture method.


  • Open Access

    Clinical Utility of the Candy-Plug Technique Using an Excluder Aortic Extender

    by Yukihisa Ogawa, Hiroshi Nishimaki, Kiyoshi Chiba, Tomotaka Iraha, Takaaki Maruhashi, Yuka Sakurai, Takeshi Miyairi, Yasuo Nakajima

    Objective: To describe the clinical utility and technical aspects of the candy-plug technique using an Excluder aortic extender (Ex-cuff) for false lumen (FL) occlusion in chronic aortic dissection.Materials and Methods: This is a retrospective study analyzing seven consecutive patients (mean age, 63 years; range, 44–78 years; 6 men) with aneurysmal dilatation or rupture in chronic aortic dissection. All patients had undergone thoracic endovascular aortic repair with FL occlusion using this technique. We assessed technical (deployment accuracy) and clinical (no FL backflow on the latest contrast-enhanced computed tomography) success.Results: Technical success was obtained in six patients (86%). Technical failure was caused by the malposition of the candy-plug. The mean follow-up period was 593 days (range, 222–1225 days). Clinical success was obtained in four (57%), and incomplete Amplatzer Vascular Plug (AVP) embolization was seen in two. There was no enlarged FL after the procedure, and all patients are alive during the follow-up periods.Conclusion: The candy-plug technique using an Ex-cuff may be a feasible option; however, it takes time to achieve complete AVP embolization. Therefore, using additional embolic materials should be considered when we use it for the rupture case. (This is a translation of Jpn J Endovasc Interv 2018; 19: 29-35.)


  • Open Access

    Clinical Utility of Coil in Plug Method (CIP) for Internal Iliac Artery Embolization during Endovascular Aortic Aneurysm Repair

    by Akiyuki Kotoku, Yukihisa Ogawa, Kiyoshi Chiba, Takaaki Maruhashi, Hidefumi Mimura, Takeshi Miyairi, Hiroshi Nishimaki

    Objective: To evaluate the clinical utility of the coil in plug (CIP) method in internal iliac artery (IIA) embolization during endovascular aortic aneurysm repair (EVAR) compared to conventional coil embolization (CCE).Material and Methods: From July to December 2018, 10 patients who underwent IIA embolization during EVAR were divided into CIP (n=5) and CCE (n=5) groups. In the CIP technique, the AVP-1 with a size more than 30%–50% of that of the embolized IIA diameter was used. The AVP-1 was deployed in the IIA. Before detachment of the AVP-1, a 2.2-F micro catheter was inserted through the 6-F delivery guiding sheath, and entered the plug. The AVP-1 was then packed with hydrogel micro coils.We compared number of coils used, embolization length, embolization time, volume embolization ratio, and embolic material cost between the groups.Results: The CIP method achieved shorter embolization length with fewer coils used compared to CCE. The CIP method decreased the cost of total embolic materials.Conclusion: The CIP method can achieve shorter embolization length with fewer coils used compared to CCE.


  • Acute Type A Dissection Causing Impending Rupture of Abdominal Aortic Aneurysm Previously Treated with EVAR

    by Yukihisa Ogawa, A. Claire Watkins, Anson Lee, Shinichi Iwakoshi, Anahita Dua, Albert J. Pedroza, Michael D. Dake, Jason T. Lee