Penumbra Pattern Assessment in Acute Stroke Patients: Comparison of Quantitative and Non-Quantitative Methods in Whole Brain CT Perfusion
Open Access
- 21 August 2014
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (8) , e105413
Abstract
While penumbra assessment has become an important part of the clinical decision making for acute stroke patients, there is a lack of studies measuring the reliability and reproducibility of defined assessment techniques in the clinical setting. Our aim was to determine reliability and reproducibility of different types of three-dimensional penumbra assessment methods in stroke patients who underwent whole brain CT perfusion imaging (WB-CTP). We included 29 patients with a confirmed MCA infarction who underwent initial WB-CTP with a scan coverage of 100 mm in the z-axis. Two blinded and experienced readers assessed the flow-volume-mismatch twice and in two quantitative ways: Performing a volumetric mismatch analysis using OsiriX imaging software (MMVOL) and visual estimation of mismatch (MMEST). Complementarily, the semiquantitative Alberta Stroke Programme Early CT Score for CT perfusion was used to define mismatch (MMASPECTS). A favorable penumbral pattern was defined by a mismatch of ≥30% in combination with a cerebral blood flow deficit of ≤90 ml and an MMASPECTS score of ≥1, respectively. Inter- and intrareader agreement was determined by Kappa-values and ICCs. Overall, MMVOL showed considerably higher inter-/intrareader agreement (ICCs: 0.751/0.843) compared to MMEST (0.292/0.749). In the subgroup of large (≥50 mL) perfusion deficits, inter- and intrareader agreement of MMVOL was excellent (ICCs: 0.961/0.942), while MMEST interreader agreement was poor (0.415) and intrareader agreement was good (0.919). With respect to penumbra classification, MMVOL showed the highest agreement (interreader agreement: 25 agreements/4 non-agreements/κ: 0.595; intrareader agreement 27/2/0.833), followed by MMEST (22/7/0.471; 23/6/0.577), and MMASPECTS (18/11/0.133; 21/8/0.340). The evaluated approach of volumetric mismatch assessment is superior to pure visual and ASPECTS penumbra pattern assessment in WB-CTP and helps to precisely judge the extent of 3-dimensional mismatch in acute stroke patients.Keywords
This publication has 24 references indexed in Scilit:
- Perfusion CT in Acute Stroke: A Comprehensive Analysis of Infarct and PenumbraRadiology, 2013
- A Randomized Trial of Tenecteplase versus Alteplase for Acute Ischemic StrokeNew England Journal of Medicine, 2012
- RAPID Automated Patient Selection for Reperfusion TherapyStroke, 2011
- CT Perfusion ASPECTS in the Evaluation of Acute Ischemic Stroke: Thrombolytic Therapy PerspectiveCerebrovascular Diseases Extra, 2011
- Advantages of Extended Brain Perfusion Computed TomographyInvestigative Radiology, 2010
- Dose Exposure of Patients Undergoing Comprehensive Stroke Imaging by Multidetector-Row CT: Comparison of 320-Detector Row and 64-Detector Row CT ScannersAmerican Journal of Neuroradiology, 2010
- Assessing Reperfusion and Recanalization as Markers of Clinical Outcomes After Intravenous Thrombolysis in the Echoplanar Imaging Thrombolytic Evaluation Trial (EPITHET)Stroke, 2009
- Refining the Perfusion–Diffusion Mismatch HypothesisStroke, 2005
- Accuracy of Dynamic Perfusion CT with Deconvolution in Detecting Acute Hemispheric Stroke2005
- Reliability of Assessing Percentage of Diffusion-Perfusion MismatchStroke, 2003