Development of a low-cost, compact, wireless, 16 - channel biopotential data acquisition, signal conditioning and arbitrary waveform stimulator
Open Access
- 4 January 2024
- journal article
- research article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (2) , 025002
Abstract
The health and fitness of the human body rely heavily on physiological parameters. These parameters can be measured using various tools such as ECG, EMG, EEG, EOG, among others, to obtain real-time physiological data. Analysing the bio-signals obtained from these measurements can provide valuable information that can be used to improve health-care in terms of observation, diagnosis, and treatment. In bio-signal pattern recognition applications, more channels provide multiple information simultaneously. Different biosignal acquisition devices are available in the market, most of which are designed for specific signals like ECG, EMG, EEG etc The gain of the amplifiers and frequency of the filters are designed as per the targeted signals; due to which one device cannot be used for other signals. Also, most of the systems are wired system which is not comfortable for animal studies. In this paper, a low-cost, compact, wireless, 16 channel biopotential data acquisition system with integrated electrical stimulator is designed and implemented. There are several novel and flexible design approaches were incorporated in the proposed design like (1) It has user selectable digital filter in each channel based on the signal frequencies like ECG, EMG, EEG, EOG. The same system will be used to acquire different signals simultaneously. (2) It has variable gain with a configurable analog bandpass filter. (3) It can acquire signals from 4 patients simultaneously. (4) The system is capable to acquire signal from both two-electrode as well as three-electrode configurations. (5) It has integrated stimulator with trapezoidal, charge-balanced, biphasic stimulus output with near zero DC level and user selectable pulse duration or frequency of the stimulus. The developed system has the ability to acquire and transmit data wirelessly in real-time at a high transfer rate. To validate the performance of the system, tests were conducted on the acquired signals using a simulator.Keywords
This publication has 24 references indexed in Scilit:
- A Microcontroller based Charge Balanced Trapezoidal Stimulus Generator for FES System2021
- NCMB-Button: A Wearable Non-contact System for Long-Term Multiple Biopotential Monitoring2017
- Technical developments of functional electrical stimulation to correct drop foot: Sensing, actuation and control strategiesClinical Biomechanics, 2015
- Bi-Fi: An Embedded Sensor/System Architecture for Remote Biological MonitoringIEEE Transactions on Information Technology in Biomedicine, 2007
- EMG and EOG artifacts in brain computer interface systems: A surveyClinical Neurophysiology, 2007
- A Wearable Point-of-Care System for Home Use That Incorporates Plug-and-Play and Wireless StandardsIEEE Transactions on Information Technology in Biomedicine, 2005
- A Multiparameter Wearable Physiologic Monitoring System for Space and Terrestrial ApplicationsIEEE Transactions on Information Technology in Biomedicine, 2005
- Bluetooth telemedicine Processor for multichannel biomedical signal transmission via mobile cellular networksIEEE Transactions on Information Technology in Biomedicine, 2005
- Towards optimal multi-channel EMG electrode configurations in muscle force estimation: a high density EMG studyJournal of Electromyography and Kinesiology, 2005
- A multichannel telemetry system for single unit neural recordingsJournal of Neuroscience Methods, 2004