Performance Testing of Different Grounding Systems
Authors:
- 2 May 2022
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Abstract
This paper presents a performance comparison of the solid, low impedance, high impedance, frequency-selective, and isolated grounding systems. A grounding system (for any power system component) is designed as an impedance (Z̄ G ) that connects the neutral point to the ground. The impedance Z̄ G is constructed using a combination of R, L, and C elements. The values and combination type (series or parallel) of R, L, C, determine the possible influence of Z̄ G on ground currents and potentials. Each grounding system is related to a system voltages level, a specific combination of R, L, C, and a range of R, L, C values. The solid, low impedance, high impedance, frequency-selective, and isolated grounding systems are designed for laboratory 3φ transformer and 3φ synchronous generator in order to compare their influences on ground currents and potentials during ground faults. The transformer and generator are tested for line-to-ground and double line-to-ground faults with all designed grounding systems. Test results show that some grounding systems can reduce ground currents only, while others can reduce ground potentials only. Such capabilities can be used to fulfill certain system and operation requirements (e.g. service continuity, ground capacity, etc.).Keywords
This publication has 17 references indexed in Scilit:
- Intrinsically Safe Grounding Systems and Global Grounding SystemsIEEE Transactions on Industry Applications, 2017
- Hybrid Grounding of Electrical SystemsIEEE Transactions on Industry Applications, 2017
- Tests and Monitoring of Grounding Systems in HV/MV SubstationsIEEE Transactions on Industry Applications, 2016
- Influence of LV Neutral Grounding on Global Earthing SystemsIEEE Transactions on Industry Applications, 2016
- Development and Testing of New Equipment for Faulty Phase Earthing by Applying RTDSIEEE Transactions on Power Delivery, 2015
- Investigation of the Overvoltage and Fast Transient Phenomena on Transformer Terminals by Taking Into Account the Grounding EffectsIEEE Transactions on Industry Applications, 2015
- On the Design and Capacity of a Grounding Configuration for Grid-Connected DGUsIEEE Transactions on Industry Applications, 2015
- The Effects of System Grounding, Bus Insulation, and Probability On Arc Flash Hazard Reduction—Part 2: TestingIEEE Transactions on Industry Applications, 2014
- Analysis of Elevated Neutral-to-Earth Voltage in Distribution Systems With Harmonic DistortionIEEE Transactions on Power Delivery, 2009
- Ground-fault currents in unit-connected generators with different elements grounding neutralIEEE Transactions on Energy Conversion, 2002