Fabrication and Validation of Sub-Cellular Carbon Fiber Electrodes
Authors:
- Julianna RichieJRJulianna Richie
- Joseph G. LetnerJLJoseph G. Letner
- Autumn Mclane-SvobodaAutumn Mclane-Svoboda
- Yu HuanYHYu Huan
- Dorsa Haji GhaffariDGDorsa Haji Ghaffari
- Elena Della ValleEVElena Della Valle
- Paras R. PatelPPParas R. Patel
- Hillel J. ChielHCHillel J. Chiel
- Galit PelledGPGalit Pelled
- James D. WeilandJWJames D. Weiland
- Cynthia A. ChestekCCCynthia A. Chestek
Open Access
- 31 January 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 739-749
Abstract
Multielectrode arrays for interfacing with neurons are of great interest for a wide range of medical applications. However, current electrodes cause damage over time. Ultra small carbon fibers help to address issues but controlling the electrode site geometry is difficult. Here we propose a methodology to create small, pointed fiber electrodes (SPFe). We compare the SPFe to previously made blowtorched fibers in characterization. The SPFe result in small site sizes $(105.4 \pm 20.8~\mu \text{m}^{{2}})$ with consistently sharp points (20.8 ± 7.64°). Additionally, these electrodes were able to record and/or stimulate neurons multiple animal models including rat cortex, mouse retina, Aplysia ganglia and octopus axial cord. In rat cortex, these electrodes recorded significantly higher peak amplitudes than the traditional blowtorched fibers. These SPFe may be applicable to a wide range of applications requiring a highly specific interface with individual neurons.Keywords
Funding Information
- National Institute of Neurological Disorders and Stroke (UF1NS115817, R01NS118606, T32NS115724)
- National Science Foundation (IOs1754869)
- NIH (1-UF1NS115817-01)
This publication has 87 references indexed in Scilit:
- Using a Common Average Reference to Improve Cortical Neuron Recordings From Microelectrode ArraysJournal of Neurophysiology, 2009
- Neural Stimulation and Recording ElectrodesAnnual Review of Biomedical Engineering, 2008
- Neural probe design for reduced tissue encapsulation in CNSBiomaterials, 2007
- The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skullJournal of Biomedical Materials Research Part A, 2007
- Model-based analysis of cortical recording with silicon microelectrodesClinical Neurophysiology, 2005
- Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral CortexIEEE Transactions on Biomedical Engineering, 2004
- The Utah Intracortical Electrode Array: A recording structure for potential brain-computer interfacesElectroencephalography and Clinical Neurophysiology, 1997
- The existence of a layer IV in the rat motor cortexCerebral Cortex, 1997
- Etched carbon-fiber electrodes as amperometric detectors of catecholamine secretion from isolated biological cellsAnalytical Chemistry, 1991
- Electrophysiological and morphological properties of rat motor cortex neurons in vivoBrain Research, 1991