JLJoseph G. Letner

Joseph G. Letner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joseph G. Letner has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Miniaturized Neural Recording Microprobe Using an On-Chip Antenna for RF Uplink Communication

    by Gabriele Atzeni, Jongyup Lim, Jiawei Liao, Jungho Lee, Joseph G. Letner, Giuseppe Mazzarella, Alessandro Fanti, Hun-Seok Kim, Cynthia A. Chestek, Jamie D. Phillips, et al.

  • Open Access

    A method for efficient, rapid, and minimally invasive implantation of individual non-functional motes with penetrating subcellular-diameter carbon fiber electrodes into rat cortex

    by Joseph G. Letner, Jordan L. W. Lam, Miranda G. Copenhaver, Michael Barrow, Paras R. Patel, Julianna M. Richie, Jungho Lee, Hun-Seok Kim, Dawen Cai, James D. Weiland, et al.

    Objective: Distributed arrays of wireless neural interfacing chips with 1-2 channels each, known as “neural dust”, could enhance brain machine interfaces (BMIs) by removing the wired connection through the scalp and increasing biocompatibility with their submillimeter size. Although several approaches for neural dust have emerged, a procedure for implanting them in batches that builds upon the safety and performance of currently used electrodes remains to be demonstrated. Approach: Here, we demonstrate the feasibility of implanting batches of wireless motes that rest on the cortical surface with carbon fiber electrodes of subcellular diameter (6.8-8.4 µm) that penetrate to a target brain depth of 1 mm without insertion aids. To simulate their implantation, we assembled more than 230 mechanically equivalent motes and affixed them to insertion tools with polyethylene glycol (PEG), a quickly dissolvable and biocompatible material. Then, we implanted mote grids of multiple configurations into rat cortex in vivo and evaluated insertion success and their arrangement on the brain surface using photos and videos captured during their implantation. Main Results: When placing motes onto the insertion device, we found that they aggregated in molten PEG such that the array pitch was only 5% wider than the dimensions of the mote bases themselves (240 x 240 µm). Overall, we found that motes with this arrangement could be inserted into rat cortex with a high success rate, as 171/186 (92%) motes in 4x4 (N=4) and 5x5 (N=5) square grid configurations were successfully inserted using the insertion device alone. After implantation, measurements of how much motes tilted (22±9°, X̄±S) and had been displaced relative to their original positions were smaller than those measured for devices implanted inside the brain in the literature. Significance: Collectively, these data establish the viability of safely implementing motes with ultrasmall electrodes and epicortically-situated chips for use in future BMIs.


  • Open Access

    Fabrication and Validation of Sub-Cellular Carbon Fiber Electrodes

    by Julianna Richie, Joseph G. Letner, Autumn Mclane-Svoboda, Yu Huan, Dorsa Haji Ghaffari, Elena Della Valle, Paras R. Patel, Hillel J. Chiel, Galit Pelled, James D. Weiland, et al.

    Multielectrode arrays for interfacing with neurons are of great interest for a wide range of medical applications. However, current electrodes cause damage over time. Ultra small carbon fibers help to address issues but controlling the electrode site geometry is difficult. Here we propose a methodology to create small, pointed fiber electrodes (SPFe). We compare the SPFe to previously made blowtorched fibers in characterization. The SPFe result in small site sizes $(105.4 \pm 20.8~\mu \text{m}^{{2}})$ with consistently sharp points (20.8 ± 7.64°). Additionally, these electrodes were able to record and/or stimulate neurons multiple animal models including rat cortex, mouse retina, Aplysia ganglia and octopus axial cord. In rat cortex, these electrodes recorded significantly higher peak amplitudes than the traditional blowtorched fibers. These SPFe may be applicable to a wide range of applications requiring a highly specific interface with individual neurons.


  • A Sub-mm3 Wireless Neural Stimulator IC for Visual Cortical Prosthesis With Optical Power Harvesting and 7.5-kb/s Data Telemetry

    by Jungho Lee, Joseph G. Letner, Jongyup Lim, Gabriele Atzeni, Jiawei Liao, Abhilasha Kamboj, Bhavika Mani, Seokhyeon Jeong, Yejoong Kim, Yi Sun, et al.

    This article proposes StiMote, an untethered, free-floating and individually addressable stimulator mote designed for visual cortex stimulation, aimed at vision restoration. The system is optically powered by a custom photovoltaic (PV) layer. In addition, the photodiode (PD) layer captures the light modulation and forwards it to the optical receiver (ORX) including a tranimpedance amplifier. Translated instructions can assign a unique slot, up to 1024 available, to each mote within the time-division multiple access (TDMA) framework. In this work, we propose an automatic charge balance (CB) technique that monitors the injected charge to balance in bi-phasic switched-capacitor stimulation (SCS). The chip was confirmed fully functional when operated completely wirelessly using harvested light. Measurement results revealed a power consumption of 4.48 $\mu$ W with a 7.5-kb/s optical downlink data rate, corresponding to continuous updates at 2.5 Hz of 1024 motes to their individual 3-b stimulation intensity levels. The dc–dc converter, responsible for providing high voltage for stimulation, demonstrated 4.3-V output voltage when unloaded, with a maximum efficiency of 67.4%. The proposed CB circuit exhibited linear controllability of stimulation charge up to 16 nC, with a charge imbalance of less than 0.2 nC. Furthermore, in vitro testing confirmed the absence of chemical reactions at electrodes, and in vivo experiments conducted on live rats verified the effectiveness of the stimulation through StiMote.


  • Open Access

    Post-explant profiling of subcellular-scale carbon fiber intracortical electrodes and surrounding neurons enables modeling of recorded electrophysiology

    by Joseph G Letner, Paras R Patel, Jung-Chien Hsieh, Israel M Smith Flores, Elena della Valle, Logan A Walker, James D Weiland, Cynthia A Chestek, Dawen Cai

    Objective. Characterizing the relationship between neuron spiking and the signals that electrodes record is vital to defining the neural circuits driving brain function and informing clinical brain-machine interface design. However, high electrode biocompatibility and precisely localizing neurons around the electrodes are critical to defining this relationship. Approach. Here, we demonstrate consistent localization of the recording site tips of subcellular-scale (6.8 µm diameter) carbon fiber electrodes and the positions of surrounding neurons. We implanted male rats with carbon fiber electrode arrays for 6 or 12+ weeks targeting layer V motor cortex. After explanting the arrays, we immunostained the implant site and localized putative recording site tips with subcellular-cellular resolution. We then 3D segmented neuron somata within a 50 µm radius from implanted tips to measure neuron positions and health and compare to healthy cortex with symmetric stereotaxic coordinates. Main results. Immunostaining of astrocyte, microglia, and neuron markers confirmed that overall tissue health was indicative of high biocompatibility near the tips. While neurons near implanted carbon fibers were stretched, their number and distribution were similar to hypothetical fibers placed in healthy contralateral brain. Such similar neuron distributions suggest that these minimally invasive electrodes demonstrate the potential to sample naturalistic neural populations. This motivated the prediction of spikes produced by nearby neurons using a simple point source model fit using recorded electrophysiology and the mean positions of the nearest neurons observed in histology. Comparing spike amplitudes suggests that the radius at which single units can be distinguished from others is near the fourth closest neuron (30.7 ± 4.6 µm, X ˉ ± S) in layer V motor cortex. Significance. Collectively, these data and simulations provide the first direct evidence that neuron placement in the immediate vicinity of the recording site influences how many spike clusters can be reliably identified by spike sorting.


  • Utah array characterization and histological analysis of a multi-year implant in non-human primate motor and sensory cortices

    by Paras R Patel, Elissa J Welle, Joseph G Letner, Hao Shen, Autumn J Bullard, Ciara M Caldwell, Alexis Vega-Medina, Julianna M Richie, Hope E Thayer, Parag G Patil, et al.

    Objective. The Utah array is widely used in both clinical studies and neuroscience. It has a strong track record of safety. However, it is also known that implanted electrodes promote the formation of scar tissue in the immediate vicinity of the electrodes, which may negatively impact the ability to record neural waveforms. This scarring response has been primarily studied in rodents, which may have a very different response than primate brain. Approach. Here, we present a rare nonhuman primate histological dataset (n = 1 rhesus macaque) obtained 848 and 590 d after implantation in two brain hemispheres. For 2 of 4 arrays that remained within the cortex, NeuN was used to stain for neuron somata at three different depths along the shanks. Images were filtered and denoised, with neurons then counted in the vicinity of the arrays as well as a nearby section of control tissue. Additionally, 3 of 4 arrays were imaged with a scanning electrode microscope to evaluate any materials damage that might be present. Main results. Overall, we found a 63% percent reduction in the number of neurons surrounding the electrode shanks compared to control areas. In terms of materials, the arrays remained largely intact with metal and Parylene C present, though tip breakage and cracks were observed on many electrodes. Significance. Overall, these results suggest that the tissue response in the nonhuman primate brain shows similar neuron loss to previous studies using rodents. Electrode improvements, for example using smaller or softer probes, may therefore substantially improve the tissue response and potentially improve the neuronal recording yield in primate cortex.


  • Open Access

    Profiling neurons surrounding subcellular-scale carbon fiber electrode tracts enables modeling recorded signals

    by Joseph G. Letner, Paras R. Patel, Jung-Chien Hsieh, Israel M. Smith Flores, Elena della Valle, Logan A. Walker, James D. Weiland, Cynthia A. Chestek, Dawen Cai

    Summary: Characterizing the relationship between neuron spiking and the signals electrodes record is vital to defining the neural circuits driving brain function and informing computational modeling. However, electrode biocompatibility and precisely localizing neurons around the electrodes are critical to defining this relationship. Here, we show the ability to localize post-explant recording tips of subcellular-scale carbon fiber electrodes and surrounding neurons. Immunostaining of astrocyte, microglia, and neuron markers confirmed improved tissue health. While neurons near implants were stretched, their number and distribution were similar to control, suggesting that these minimally invasive electrodes demonstrate the potential to sample naturalistic neural populations. This motivated prediction of the spikes produced by neurons nearest to the electrodes using a model fit with recorded electrophysiology. These simulations show the first direct evidence that neuron placement in the immediate vicinity of the recording site influences how many spike clusters can be reliably identified by spike sorting.

  • Open Access

    Utah Array Characterization and Histological Analysis of a Multi-Year Implant in Non-Human Primate Motor and Sensory Cortices

    by Paras R. Patel, Elissa J. Welle, Joseph G. Letner, Hao Shen, Autumn J. Bullard, Ciara M. Caldwell, Alexis Vega-Medina, Julianna M. Richie, Hope E. Thayer, Parag G. Patil, et al.

    The Utah array is widely used in both clinical studies and neuroscience. It has a strong track record of safety. However, it is also known that implanted electrodes promote the formation of scar tissue in the immediate vicinity of the electrodes, which negatively impacts the ability to record neural waveforms. This scarring response has been primarily studied in rats and mice, which may have a very different response than primate brain. Here, we present a rare nonhuman primate histological dataset (n=1 rhesus macaque) obtained 848 and 590 days after implantation in two brain hemispheres. For 2 of 4 arrays that remained within the cortex, NeuN was used to stain for neuron somata at 3 different electrode depths. Images were filtered and denoised, with neurons then counted in the vicinity of the arrays as well as a nearby section of control tissue. Additionally, 3 of 4 arrays were imaged with a scanning electrode microscope (SEM) to evaluate any materials damage that might be present. Overall, we found a 63% percent reduction in the number of neurons surrounding the electrode compared to control areas. In terms of materials, the arrays remained largely intact with metal and Parylene C present, though tip breakage and cracks were observed on many electrodes. Overall, these results suggest that the tissue response in the nonhuman primate brain shows similar neuron loss to previous studies using rodents. Electrode improvements, for example using smaller or softer probes, may therefore substantially increase the neuronal recording yield in primate cortex.