A patient-specific numerical model of the ankle joint for the analysis of contact pressure distribution
- 25 June 2020
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 234 (9) , 909-920
Abstract
A patient-specific numerical model of the ankle joint has been developed using open-source software with realistic material properties that mimics the physiological movement of the foot during the stance phase of the gait cycle. The patient-specific ankle geometry has been segmented as a castellated surface using 3DSlicer from the computed tomography image scans of a subject with no congenital or acquired pathology; subsequently, the bones are smoothed, and cartilage is included as a uniform thickness extruded layer. A high-resolution Cartesian mesh has been generated using cfMesh. The material properties are assigned in the model based on the CT image Hounsfield intensities and compared to a sandwich-based material model. Gait data of the same subject was obtained and used to relatively position the tibia, talus, and calcaneus bones in the model. The stance phase of the gait cycle is simulated using a cell-centred finite-volume method implemented in open-source software OpenFOAM. The predicted peak contact pressures occur in the range of 4.85–5.53 MPa with average pressures in the range of 1.56–1.95 MPa, and the contact area ranges between 429 and 707.8 mm2 for the entire stance phase with the mid-stance phase predicting the maximum contact area. These predictions are in agreement with results from the literature. The effect of arthritis on the contact characteristics of the ankle joint has also been examined. A concentrated increase in pressure was predicted that could be manifested as pain, thereby leading to reduced motion in the ankle. The model, with continued development, has the capability to understand the effect of joint degradation and furthermore, could help provide a tool to predict the efficiency of therapeutic surgical procedures as well as guide the development of next generation ankle prostheses. The work would be made available in the University College Dublin depository ( https://github.com/laxmimurali/anklejoint ) as well as research gate once the article has been published.Keywords
Funding Information
- Irish Research Council
This publication has 48 references indexed in Scilit:
- A Dynamic Finite Element Analysis of Human Foot Complex in the Sagittal Plane during Level WalkingPLOS ONE, 2013
- Effects of idealized joint geometry on finite element predictions of cartilage contact stresses in the hipJournal of Biomechanics, 2010
- In Vivo Kinematics of the Tibiotalar Joint After Lateral Ankle InstabilityThe American Journal of Sports Medicine, 2009
- Finite Element Analysis of the Proximal Femur and Hip Fracture Risk in Older MenJournal of Bone and Mineral Research, 2009
- Validation of Finite Element Predictions of Cartilage Contact Pressure in the Human Hip JointJournal of Biomechanical Engineering, 2008
- Cartilage Thickness: Factors Influencing Multidetector CT Measurements in a Phantom StudyRadiology, 2008
- A CT-Based High-Order Finite Element Analysis of the Human Proximal Femur Compared to In-vitro ExperimentsJournal of Biomechanical Engineering, 2006
- Finite volume method and multigrid acceleration in modelling of rapid crack propagation in full-scale pipe testComputational Mechanics, 1997
- An asymptotic solution for the contact of two biphasic cartilage layersJournal of Biomechanics, 1994
- Load-bearing pattern of the ankle jointArchives of orthopaedic and trauma surgery, 1980