Laxmi Muralidharan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Laxmi Muralidharan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Alojz Ivanković
School of Mechanical and Materials Engineering, University College Dublin, Dublin, Ireland
1 shared publication- Carlos Milovic
Department of Electrical Engineering, Pontificia Universidad Catolica de Chile, Santiago, Chile; Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, Chile
1 shared publication Jannette Nassar
Department of Medical Physics and Biomedical Engineering, University College London, UK
1 shared publicationKaren Fitzgerald
School of Mechanical and Materials Engineering, University College Dublin, Dublin, Ireland
1 shared publication- Karin Shmueli
Department of Medical Physics and Biomedical Engineering, University College London, UK
1 shared publication Mathias Lambert
Department of Electrical Engineering, Pontificia Universidad Catolica de Chile, Santiago, Chile; Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, Chile
1 shared publication
Latest Publications
- Open Access
- 1 October 2025
- Published by Elsevier in NeuroImage
- Vol. 321, 121499
Investigating the effect of masking and background field removal algorithms on the quality of QSM reconstructions using a realistic numerical head phantom
- 1 October 2025
- Published by Elsevier in NeuroImage
- Vol. 321, 121499
Open AccessInvestigating the effect of masking and background field removal algorithms on the quality of QSM reconstructions using a realistic numerical head phantom
- 25 June 2020
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 234 (9) , 909-920
A patient-specific numerical model of the ankle joint for the analysis of contact pressure distribution
A patient-specific numerical model of the ankle joint has been developed using open-source software with realistic material properties that mimics the physiological movement of the foot during the stance phase of the gait cycle. The patient-specific ankle geometry has been segmented as a castellated surface using 3DSlicer from the computed tomography image scans of a subject with no congenital or acquired pathology; subsequently, the bones are smoothed, and cartilage is included as a uniform thickness extruded layer. A high-resolution Cartesian mesh has been generated using cfMesh. The material properties are assigned in the model based on the CT image Hounsfield intensities and compared to a sandwich-based material model. Gait data of the same subject was obtained and used to relatively position the tibia, talus, and calcaneus bones in the model. The stance phase of the gait cycle is simulated using a cell-centred finite-volume method implemented in open-source software OpenFOAM. The predicted peak contact pressures occur in the range of 4.85–5.53 MPa with average pressures in the range of 1.56–1.95 MPa, and the contact area ranges between 429 and 707.8 mm2 for the entire stance phase with the mid-stance phase predicting the maximum contact area. These predictions are in agreement with results from the literature. The effect of arthritis on the contact characteristics of the ankle joint has also been examined. A concentrated increase in pressure was predicted that could be manifested as pain, thereby leading to reduced motion in the ankle. The model, with continued development, has the capability to understand the effect of joint degradation and furthermore, could help provide a tool to predict the efficiency of therapeutic surgical procedures as well as guide the development of next generation ankle prostheses. The work would be made available in the University College Dublin depository ( https://github.com/laxmimurali/anklejoint ) as well as research gate once the article has been published.
- 25 June 2020
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 234 (9) , 909-920
A patient-specific numerical model of the ankle joint for the analysis of contact pressure distribution
A patient-specific numerical model of the ankle joint has been developed using open-source software with realistic material properties that mimics the physiological movement of the foot during the stance phase of the gait cycle. The patient-specific ankle geometry has been segmented as a castellated surface using 3DSlicer from the computed tomography image scans of a subject with no congenital or acquired pathology; subsequently, the bones are smoothed, and cartilage is included as a uniform thickness extruded layer. A high-resolution Cartesian mesh has been generated using cfMesh. The material properties are assigned in the model based on the CT image Hounsfield intensities and compared to a sandwich-based material model. Gait data of the same subject was obtained and used to relatively position the tibia, talus, and calcaneus bones in the model. The stance phase of the gait cycle is simulated using a cell-centred finite-volume method implemented in open-source software OpenFOAM. The predicted peak contact pressures occur in the range of 4.85–5.53 MPa with average pressures in the range of 1.56–1.95 MPa, and the contact area ranges between 429 and 707.8 mm2 for the entire stance phase with the mid-stance phase predicting the maximum contact area. These predictions are in agreement with results from the literature. The effect of arthritis on the contact characteristics of the ankle joint has also been examined. A concentrated increase in pressure was predicted that could be manifested as pain, thereby leading to reduced motion in the ankle. The model, with continued development, has the capability to understand the effect of joint degradation and furthermore, could help provide a tool to predict the efficiency of therapeutic surgical procedures as well as guide the development of next generation ankle prostheses. The work would be made available in the University College Dublin depository ( https://github.com/laxmimurali/anklejoint ) as well as research gate once the article has been published.