Programmable Transimpedance Amplifier with Integrated Bandgap Reference for Glucose Concentration Measurement
Preprint
Abstract
For glucose electrochemical sensors, a comprehensive electronics interface is designed and constructed in 0.18 um, CMOS process technology, and 1.5 V supply voltage. This interface includes a programmable readout amplifier and bandgap reference voltage potentiostat circuit. The programmable transimpedance amplifier (PTIA), the proposed readout circuit, provides a large dynamic range and low noise. The overall transimpedance increase for the PTIA is 17.3-50.5 kohm. For an input current range of 4.2-180 uA, the PTIA response has a linear output voltage range of 0.55-1.44 V. The output rms noise value is calculated to be 5.101 Vrms, and the overall power consumption of the design is 2.33 mW. The THD percentage spans from 7.6 to 10.2 in the current range mentioned above. All bandgap reference voltage potentiostat measurements are made using the reference potential of 0.6 V. The working electrode was a glassy carbon electrode (GCE) loaded with a CuO/Cu0:76CO2:25O4 (copper cobaltite) coating. An electrochemical glucose sensing setup has been used to measure glucose concentrations between 1 and 10 mM, and an emulated circuit has been used to verify the viability of the proposed glucose sensing design. The suggested glucose sensor architecture has a total size of 0.0684 mm2.Keywords
All Related Versions
This publication has 41 references indexed in Scilit:
- Reinforcement Learning Models and Algorithms for Diabetes ManagementIEEE Access, 2023
- Novel tunable current feedback instrumentation amplifier based on BBFC OP-AMP for biomedical applications with low power and high CMRRIntegration, 2023
- Novel Programmable Readout Amplifier and Potentiostat for Glucose Sensing ApplicationsSN Computer Science, 2022
- Machine learning models for non-invasive glucose measurement: towards diabetes management in smart healthcareHealth and Technology, 2022
- A remote healthcare monitoring framework for diabetes prediction using machine learningHealthcare Technology Letters, 2021
- On the design of improved resistive sensor interface using 32 nm CNFETMaterials Today: Proceedings, 2021
- Use of Machine Learning Approaches in Clinical Epidemiological Research of DiabetesCurrent Diabetes Reports, 2020
- A low-power low-noise multi-stage transimpedance amplifier for amperometric based blood glucose monitoring systemsAnalog Integrated Circuits and Signal Processing, 2020
- Low power, low noise, compact amperometric circuit for three-terminal glucose biosensorAnalog Integrated Circuits and Signal Processing, 2016
- A comparison between potentiostatic circuits with grounded work or auxiliary electrodeReview of Scientific Instruments, 2002