Purpose: To demonstrate the interchangeable neck shape–specific (NSS) coil concept that supplements standard commercial spine and head/neck coils to provide simultaneous high‐resolution (hi‐res) head/neck imaging with high signal‐to‐noise ratio (SNR).Methods: Two NSS coils were constructed on formers designed to fit two different neck shapes. A 7‐channel (7ch) ladder array was constructed on a medium neck former, and a 9‐channel (9ch) ladder array was constructed on large neck former. Both coils were interchangeable with the same preamp housing.Results: The 7ch and 9ch coils demonstrate SNR gains of approximately 4 times and 3 times over the Siemens 20‐channel head/neck coil in the carotid arteries of our volunteers, respectively. Coupling between the Siemens 32‐channel spine coil, Siemens 20‐channel head/neck coil, and the NSS coils was negligible, allowing for simultaneous hi‐res head/neck imaging with high SNR.Conclusions: This study demonstrates that supplementing existing commercial spine and head/neck coils with an NSS coil allows uniform simultaneous hi‐res imaging with high SNR in the anterior neck, while maintaining SNR of the commercial coil in the head and posterior neck. Magn Reson Med 78:2460–2468, 2017. © 2017 International Society for Magnetic Resonance in Medicine.Keywords
Funding Information
- NIH (R01 HL 127582)
This publication has 19 references indexed in Scilit:
- DANTE‐prepared pulse trains: A novel approach to motion‐sensitized and motion‐suppressed quantitative magnetic resonance imagingMagnetic Resonance in Medicine, 2012
- 32‐Channel RF coil optimized for brain and cervical spinal cord at 3 TMagnetic Resonance in Medicine, 2011
- Improvements in carotid plaque imaging using a new eight‐element phased array coil at 3TJournal of Magnetic Resonance Imaging, 2009
- 96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluationMagnetic Resonance in Medicine, 2009
- Reducing morphological variability of the cervical carotid artery in serial magnetic resonance imaging using a head and neck immobilization deviceJournal of Magnetic Resonance Imaging, 2008
- 32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometryMagnetic Resonance in Medicine, 2006
- Image reconstruction in SNR units: A general method for SNR measurement†Magnetic Resonance in Medicine, 2005
- Relative RF coil performance in carotid imagingMagnetic Resonance Imaging, 2005
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Surface coil phased arrays for high‐resolution imaging of the carotid arteriesJournal of Magnetic Resonance Imaging, 1996