    Quasistatic Solutions versus Full-Wave Solutions of Single-Channel Circular RF Receive Coils on Phantoms of Varying Conductivities at 3 Tesla

    by Michael J. Beck, Dennis L. Parker, J. Rock Hadley

    Purpose. Although full-wave simulations could be used to aid in RF coil design, the algorithms may be too slow for an iterative optimization algorithm. If quasistatic simulations are accurate within the design tolerance, then their use could reduce simulation time by orders of magnitude compared to full-wave simulations. This paper examines the accuracy of quasistatic and full-wave simulations at 3 Tesla. Methods. Three sets of eight coils ranging from 310cm (24 total) were used to measure SNR on three phantoms with conductivities of 0.3, 0.6, and 0.9S/m. The phantom conductivities were chosen to represent those typically found in human tissues. The range of coil element sizes represents the sizes of coil elements seen in typical coil designs. SNR was determined using the magnetic and electric fields calculated by quasistatic and full-wave simulations. Each simulated SNR dataset was scaled to minimize the root mean squared error (RMSE) when compared against measured SNR data. In addition, the noise values calculated by each simulation were compared against benchtop measured noise values. Results. The RMSE was 0.285 and 0.087 for the quasistatic and full-wave simulations, respectively. The maximum and minimum quotient values, when taking the ratio of simulated to measured SNR values, were 1.69 and 0.20 for the quasistatic simulations and 1.29 and 0.75 for the full-wave simulations, respectively. The ratio ranges, for the calculated quasistatic and full-wave total noise values compared to benchtop measured noise values, were 0.831.06 and 0.273.02, respectively. Conclusions. Full-wave simulations were on average 3x more accurate than the quasistatic simulations. Full-wave simulations were more accurate in characterizing the wave effects within the sample, though they were not able to fully account for the skin effect when calculating coil noise.

  • Open Access

    Capacitive versus Overlap Decoupling of Adjacent Radio Frequency Phased Array Coil Elements: An Imaging Robustness Comparison When Sample Load Varies for 3 Tesla MRI

    by Michael J. Beck, Dennis L. Parker, J. Rock Hadley

    Phased array (PA) receive coils are built such that coil elements approximate independent antenna behavior. One method of achieving this goal is to use an available decoupling method to decouple adjacent coil elements. The purpose of this work was to compare the relative performance of two decoupling methods as a function of variation in sample load. Two PA receive coils with 5 channels (5-ch) each, equal outer dimensions, and formed on 12 cm diameter cylindrical phantoms of conductivities 0.3, 0.6, and 0.9 S/m were evaluated for relative signal-to-noise ratio (SNR) and parallel imaging performance. They were only tuned and matched to the 0.6 S/m phantom. Simulated and measured axial, sagittal, and coronal 5-ch PA coil SNR ratios were compared by dividing the overlap by the capacitive decoupled coil SNR results. Issues related to the selection of capacitor values for the two decoupling methods were evaluated by taking the ratio of the match and tune capacitors for large and small 2 channel (2-ch) PA coils. The SNR ratios showed that the SNR of the two decoupling methods were very similar. The inverse geometry-factor maps showed similar but better overall parallel imaging performance for the capacitive decoupled method. The quotients for the 2-ch PA coils’ maximum and minimum capacitor value ratios are 3.28 and 1.38 for the large and 3.28 and 2.22 for the small PA. The results of this paper demonstrate that as the sample load varies, the capacitive and overlap decoupling methods are very similar in relative SNR and this similarity continues for parallel imaging performance. Although, for the 5-ch coils studied, the capacitive decoupling method has a slight SNR and parallel imaging advantage and it was noted that the capacitive decoupled coil is more likely to encounter unbuildable PA coil configurations.


  • Open Access

    Interchangeable neck shape–specific coils for a clinically realizable anterior neck phased array system

    by Michael J. Beck, Dennis L. Parker, Bradley D. Bolster, Seong‐Eun Kim, J. Scott McNally, Gerald S. Treiman, J. Rock Hadley

    Purpose: To demonstrate the interchangeable neck shape–specific (NSS) coil concept that supplements standard commercial spine and head/neck coils to provide simultaneous high‐resolution (hi‐res) head/neck imaging with high signal‐to‐noise ratio (SNR).Methods: Two NSS coils were constructed on formers designed to fit two different neck shapes. A 7‐channel (7ch) ladder array was constructed on a medium neck former, and a 9‐channel (9ch) ladder array was constructed on large neck former. Both coils were interchangeable with the same preamp housing.Results: The 7ch and 9ch coils demonstrate SNR gains of approximately 4 times and 3 times over the Siemens 20‐channel head/neck coil in the carotid arteries of our volunteers, respectively. Coupling between the Siemens 32‐channel spine coil, Siemens 20‐channel head/neck coil, and the NSS coils was negligible, allowing for simultaneous hi‐res head/neck imaging with high SNR.Conclusions: This study demonstrates that supplementing existing commercial spine and head/neck coils with an NSS coil allows uniform simultaneous hi‐res imaging with high SNR in the anterior neck, while maintaining SNR of the commercial coil in the head and posterior neck. Magn Reson Med 78:2460–2468, 2017. © 2017 International Society for Magnetic Resonance in Medicine.