Phase-stability optimization of swept-source optical coherence tomography
Authors:
- 9 October 2018
- journal article
- research article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (11) , 5280-5295
Abstract
Phase-resolved imaging of swept-source optical coherence tomography (SS-OCT) is subject to phase measurement instabilities involved with the sweep variation of a frequency-swept source. In general, optically generated timing references are utilized to track the variations imposed on OCT signals. But they might not be accurately synchronized due to relative time delays. In this research, we investigated the impact of the signal delays on the timing instabilities and the consequent deviations of the measured phases. We considered two types of timing signals utilized in a popular digitizer operation mode: a sweep trigger from a fiber Bragg grating (FBG) that initiates a series of signal sampling actions clocked by an auxiliary Mach-Zehnder interferometer (MZI) signal. We found that significant instabilities were brought by the relative delays through incoherent timing corrections and timing collisions between the timing references. The best-to-worst ratio of the measured phase errors was higher than 200 while only the signal delays varied. Noise-limited phase stability was achieved with a wide dynamic range of OCT signals above 50 dB in optimized delays. This demonstrated that delay optimization is very effective in phase stabilization of SS-OCT.Keywords
Funding Information
- National Institutes of Health (NIH) (P41EB-015890, R01EY-021529, R01EY-026091, R01EY-028662, R01HL-125084, R01HL-127271)
This publication has 32 references indexed in Scilit:
- High-speed spectral calibration by complex FIR filter in phase-sensitive optical coherence tomographyBiomedical Optics Express, 2016
- Phase-sensitive optical coherence elastography at 15 million A-Lines per secondOptics Letters, 2015
- Retinal, anterior segment and full eye imaging using ultrahigh speed swept source OCT with vertical-cavity surface emitting lasersBiomedical Optics Express, 2012
- Phase-stabilized optical frequency domain imaging at 1-µm for the measurement of blood flow in the human choroidOptics Express, 2011
- Doppler velocity detection limitations in spectrometer-based versus swept-source optical coherence tomographyBiomedical Optics Express, 2011
- Generic real-time uniform K-space sampling method for high-speed swept-Source optical coherence tomographyOptics Express, 2010
- Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging rangeOptics Express, 2009
- K-space linear Fourier domain mode locked laser and applications for optical coherence tomographyOptics Express, 2008
- Optical coherence angiographyOptics Express, 2006
- Real-time fiber-based multi-functional spectral-domain optical coherence tomography at 13 µmOptics Express, 2005