Vernard S. Fennell
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vernard S. Fennell has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Adnan H. Siddiqui
Department of Neurosurgery, State University of New York at Buffalo, Buffalo, New York, USA
4 shared publications - Daniel R. Bednarek
Canon Stroke and Vascular Research Ctr., Univ. at Buffalo (United States)
3 shared publications - Elad I. Levy
Department of Neurosurgery, State University of New York at Buffalo, Buffalo, New York, USA
3 shared publications - Jason M. Davies
Neurosurgery and Bioinformatics and Canon Stroke and Vascular Research Center, University at Buffalo Jacobs School of Medicine and Biomedical Sciences, Buffalo, New York, USA
3 shared publications - Stephen Rudin
Canon Stroke and Vascular Research Ctr., Univ. at Buffalo (United States)
3 shared publications - Ciprian Nicolae Ionita
Department of Biomedical Engineering University at Buffalo Buffalo USA
2 shared publications
Latest Publications
- 25 July 2020
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 19 (6) , 735-740
A Minimally Invasive Endoscopic Technique for Fascia Lata Graft Acquisition and Fascial Reapproximation
BACKGROUND: Fascia lata remains a popular and robust graft to repair osteodural defects in endoscopic neurosurgery. Classically, this graft is obtained via a large incision in the thigh that is prone to pain and muscle herniation after surgery. OBJECTIVE: To present a novel technique for harvesting fat and fascia lata graft and reapproximating the edges via an endoscopic approach through the thigh using an “outside-in” technique to prevent muscle herniation. METHODS: Initially our technique was performed in cadavers and includes the following: small 2 cm incision in the lateral thigh to accommodate the endoscope, use of blunt dissection and endoscopic tools to obtain the graft, and reapproximation of the fascia via an outside-in technique using conventional sutures with endoscopic visualization to retrieve the sutures beneath the skin and tie them. We then applied the technique to a patient undergoing transsphenoidal tumor resection. RESULTS: This technique was trialed in 3 cadaver specimens (6 limbs) and was used successfully in a patient with excellent cosmetic results seen in follow-up. CONCLUSION: Endoscopic retrieval of fascia lata is feasible via a very small incision. Reapproximation of the cut fascial edges to minimize muscle herniation can quickly and easily be performed with an outside-in technique detailed here. Additional case series may help to solidify the endoscopic retrieval as a preferred technique for fascia lata graft.
- 25 July 2020
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 19 (6) , 735-740
A Minimally Invasive Endoscopic Technique for Fascia Lata Graft Acquisition and Fascial Reapproximation
BACKGROUND: Fascia lata remains a popular and robust graft to repair osteodural defects in endoscopic neurosurgery. Classically, this graft is obtained via a large incision in the thigh that is prone to pain and muscle herniation after surgery. OBJECTIVE: To present a novel technique for harvesting fat and fascia lata graft and reapproximating the edges via an endoscopic approach through the thigh using an “outside-in” technique to prevent muscle herniation. METHODS: Initially our technique was performed in cadavers and includes the following: small 2 cm incision in the lateral thigh to accommodate the endoscope, use of blunt dissection and endoscopic tools to obtain the graft, and reapproximation of the fascia via an outside-in technique using conventional sutures with endoscopic visualization to retrieve the sutures beneath the skin and tie them. We then applied the technique to a patient undergoing transsphenoidal tumor resection. RESULTS: This technique was trialed in 3 cadaver specimens (6 limbs) and was used successfully in a patient with excellent cosmetic results seen in follow-up. CONCLUSION: Endoscopic retrieval of fascia lata is feasible via a very small incision. Reapproximation of the cut fascial edges to minimize muscle herniation can quickly and easily be performed with an outside-in technique detailed here. Additional case series may help to solidify the endoscopic retrieval as a preferred technique for fascia lata graft.
- Open Access
- 24 July 2019
- Published by Wiley in Journal of Neuroimaging
- Vol. 29 (5) , 565-572
High‐Definition Zoom Mode: A High Resolution X‐ray Microscope for Neurointerventional Treatment Procedures
BACKGROUND AND PURPOSE: Visualization of structural details of treatment devices during neurointerventional procedures can be challenging. A new true two‐resolution imaging X‐ray detector system features a 194 µm pixel conventional flat‐panel detector (FPD) mode and a 76 µm pixel high‐resolution high‐definition (Hi‐Def) zoom mode in one detector panel. The Hi‐Def zoom mode was developed for use in interventional procedures requiring superior image quality over a small field of view (FOV). We report successful use of this imaging system during intracranial aneurysm treatment in 1 patient with a Pipeline‐embolization device and 1 patient with a low‐profile visualized intramural support (LVIS Blue) device plus adjunctive coiling. METHODS: A guide catheter was advanced from the femoral artery insertion site to the proximity of each lesion using standard FPD mode. Under magnified small FOV Hi‐Def imaging mode, an intermediate catheter and microcatheters were guided to the treatment site, and the PED and LVIS Blue plus coils were deployed. Radiation doses were tracked intraprocedurally. RESULTS: Critical details, including structural changes in the PED and LVIS Blue and position and movement of the microcatheter tip within the coil mass, were more readily apparent in Hi‐Def mode. Skin‐dose mapping indicated that Hi‐Def mode limited radiation exposure to the smaller FOV of the treatment area. CONCLUSIONS: Visualization of device structures was much improved in the high‐resolution Hi‐Def mode, leading to easier, more controlled deployment of stents and coils than conventional FPD mode.
- 24 July 2019
- Published by Wiley in Journal of Neuroimaging
- Vol. 29 (5) , 565-572
Open AccessHigh‐Definition Zoom Mode: A High Resolution X‐ray Microscope for Neurointerventional Treatment Procedures
BACKGROUND AND PURPOSE: Visualization of structural details of treatment devices during neurointerventional procedures can be challenging. A new true two‐resolution imaging X‐ray detector system features a 194 µm pixel conventional flat‐panel detector (FPD) mode and a 76 µm pixel high‐resolution high‐definition (Hi‐Def) zoom mode in one detector panel. The Hi‐Def zoom mode was developed for use in interventional procedures requiring superior image quality over a small field of view (FOV). We report successful use of this imaging system during intracranial aneurysm treatment in 1 patient with a Pipeline‐embolization device and 1 patient with a low‐profile visualized intramural support (LVIS Blue) device plus adjunctive coiling. METHODS: A guide catheter was advanced from the femoral artery insertion site to the proximity of each lesion using standard FPD mode. Under magnified small FOV Hi‐Def imaging mode, an intermediate catheter and microcatheters were guided to the treatment site, and the PED and LVIS Blue plus coils were deployed. Radiation doses were tracked intraprocedurally. RESULTS: Critical details, including structural changes in the PED and LVIS Blue and position and movement of the microcatheter tip within the coil mass, were more readily apparent in Hi‐Def mode. Skin‐dose mapping indicated that Hi‐Def mode limited radiation exposure to the smaller FOV of the treatment area. CONCLUSIONS: Visualization of device structures was much improved in the high‐resolution Hi‐Def mode, leading to easier, more controlled deployment of stents and coils than conventional FPD mode.
- Open Access
- 24 January 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (2) , 288-294
Ostium Ratio and Neck Ratio Could Predict the Outcome of Sidewall Intracranial Aneurysms Treated with Flow Diverters
BACKGROUND AND PURPOSE: Incompletely occluded flow diverter treated aneurysms remain at risk of rupture and thromboembolic complications. Our aim was to identify the potential for incomplete occlusion of intracranial aneurysms treated by flow diverters. We investigated whether aneurysm ostium size in relation to parent artery size affects angiographic outcomes of flow diverter–treated sidewall aneurysms. MATERIALS AND METHODS: Flow diverter–treated sidewall aneurysms were divided into “occluded” and “residual” (incomplete occlusion) groups based on 6-month angiographic follow-up. We calculated the ostium ratio, a new parameter defined as the aneurysm ostium surface area versus the circumferential surface area of the parent artery. We also calculated the neck ratio, defined as clinical aneurysm neck diameter versus parent artery diameter from pretreatment 2D DSA, as a 2D surrogate. We compared the performance of these ratios with existing aneurysm morphometrics (size, neck diameter, volume, aspect ratio, size ratio, undulation index, nonsphericity index, ellipticity index, bottleneck factor, aneurysm angle, and parent vessel angle) and flow diverter–related parameters (metal coverage rate and pore density). Statistical tests and receiver operating characteristic analyses were performed to identify significantly different parameters between the 2 groups and test their predictive performances. RESULTS: We included 63 flow diverter–treated aneurysms, 46 occluded and 17 residual. The ostium ratio and neck ratio were significantly higher in the residual group than in the occluded group (P < .001 and P = .02, respectively), whereas all other parameters showed no statistical difference. As discriminating parameters for occlusion, ostium ratio and neck ratio achieved areas under the curve of 0.912 (95% CI, 0.838–0.985) and 0.707 (95% CI, 0.558–0.856), respectively. CONCLUSIONS: High ostium ratios and neck ratios could predict incomplete occlusion of flow diverter–treated sidewall aneurysms. Neck ratio can be easily calculated by interventionists to predict flow-diverter treatment outcomes.
- 24 January 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (2) , 288-294
Open AccessOstium Ratio and Neck Ratio Could Predict the Outcome of Sidewall Intracranial Aneurysms Treated with Flow Diverters
BACKGROUND AND PURPOSE: Incompletely occluded flow diverter treated aneurysms remain at risk of rupture and thromboembolic complications. Our aim was to identify the potential for incomplete occlusion of intracranial aneurysms treated by flow diverters. We investigated whether aneurysm ostium size in relation to parent artery size affects angiographic outcomes of flow diverter–treated sidewall aneurysms. MATERIALS AND METHODS: Flow diverter–treated sidewall aneurysms were divided into “occluded” and “residual” (incomplete occlusion) groups based on 6-month angiographic follow-up. We calculated the ostium ratio, a new parameter defined as the aneurysm ostium surface area versus the circumferential surface area of the parent artery. We also calculated the neck ratio, defined as clinical aneurysm neck diameter versus parent artery diameter from pretreatment 2D DSA, as a 2D surrogate. We compared the performance of these ratios with existing aneurysm morphometrics (size, neck diameter, volume, aspect ratio, size ratio, undulation index, nonsphericity index, ellipticity index, bottleneck factor, aneurysm angle, and parent vessel angle) and flow diverter–related parameters (metal coverage rate and pore density). Statistical tests and receiver operating characteristic analyses were performed to identify significantly different parameters between the 2 groups and test their predictive performances. RESULTS: We included 63 flow diverter–treated aneurysms, 46 occluded and 17 residual. The ostium ratio and neck ratio were significantly higher in the residual group than in the occluded group (P < .001 and P = .02, respectively), whereas all other parameters showed no statistical difference. As discriminating parameters for occlusion, ostium ratio and neck ratio achieved areas under the curve of 0.912 (95% CI, 0.838–0.985) and 0.707 (95% CI, 0.558–0.856), respectively. CONCLUSIONS: High ostium ratios and neck ratios could predict incomplete occlusion of flow diverter–treated sidewall aneurysms. Neck ratio can be easily calculated by interventionists to predict flow-diverter treatment outcomes.
- Open Access
- 27 December 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (2) , 302-308
High-Definition Zoom Mode, a High-Resolution X-Ray Microscope for Neurointerventional Treatment Procedures: A Blinded-Rater Clinical-Utility Study
BACKGROUND AND PURPOSE: Quality of visualization of treatment devices during critical stages of endovascular interventions, can directly impact their safety and efficacy. Our aim was to compare the visualization of neurointerventional procedures and treatment devices using a 194-μm pixel flat panel detector mode and a 76-μm pixel complementary metal oxide semiconductor detector mode (high definition) of a new-generation x-ray detector system using a blinded-rater study. MATERIALS AND METHODS: Deployment of flow-diversion devices for the treatment of internal carotid artery aneurysms was performed under flat panel detector and high-definition-mode image guidance in a neurointerventional phantom simulating patient cranium and tissue attenuation, embedded with 3D-printed intracranial vascular models, each with an aneurysm in the ICA segment. Image-sequence pairs of device deployments for each detector mode, under similar exposure and FOV conditions, were evaluated by 2 blinded experienced neurointerventionalists who independently selected their preferred image on the basis of visualization of anatomic features, image noise, and treatment device. They rated their selection as either similar, better, much better, or substantially better than the other choice. Inter- and intrarater agreement was calculated and categorized as poor, moderate, and good. RESULTS: Both raters demonstrating good inter- and intrarater agreement selected high-definition-mode images with a frequency of at least 95% each and, on average, rated the high-definition images as much better than flat panel detector images with a frequency of 73% from a total of 60 image pairs. CONCLUSIONS: Due to their higher resolution, high-definition-mode images are sharper and visually preferred compared with the flat panel detector images. The improved imaging provided by the high-definition mode can potentially provide an advantage during neurointerventional procedures.
- 27 December 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (2) , 302-308
Open AccessHigh-Definition Zoom Mode, a High-Resolution X-Ray Microscope for Neurointerventional Treatment Procedures: A Blinded-Rater Clinical-Utility Study
BACKGROUND AND PURPOSE: Quality of visualization of treatment devices during critical stages of endovascular interventions, can directly impact their safety and efficacy. Our aim was to compare the visualization of neurointerventional procedures and treatment devices using a 194-μm pixel flat panel detector mode and a 76-μm pixel complementary metal oxide semiconductor detector mode (high definition) of a new-generation x-ray detector system using a blinded-rater study. MATERIALS AND METHODS: Deployment of flow-diversion devices for the treatment of internal carotid artery aneurysms was performed under flat panel detector and high-definition-mode image guidance in a neurointerventional phantom simulating patient cranium and tissue attenuation, embedded with 3D-printed intracranial vascular models, each with an aneurysm in the ICA segment. Image-sequence pairs of device deployments for each detector mode, under similar exposure and FOV conditions, were evaluated by 2 blinded experienced neurointerventionalists who independently selected their preferred image on the basis of visualization of anatomic features, image noise, and treatment device. They rated their selection as either similar, better, much better, or substantially better than the other choice. Inter- and intrarater agreement was calculated and categorized as poor, moderate, and good. RESULTS: Both raters demonstrating good inter- and intrarater agreement selected high-definition-mode images with a frequency of at least 95% each and, on average, rated the high-definition images as much better than flat panel detector images with a frequency of 73% from a total of 60 image pairs. CONCLUSIONS: Due to their higher resolution, high-definition-mode images are sharper and visually preferred compared with the flat panel detector images. The improved imaging provided by the high-definition mode can potentially provide an advantage during neurointerventional procedures.
- Open Access
- 15 February 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (4) , 734-741
A Patient Dose-Reduction Technique for Neuroendovascular Image-Guided Interventions: Image-Quality Comparison Study
BACKGROUND AND PURPOSE: The ROI–dose-reduced intervention technique represents an extension of ROI fluoroscopy combining x-ray entrance skin dose reduction with spatially different recursive temporal filtering to reduce excessive image noise in the dose-reduced periphery in real-time. The aim of our study was to compare the image quality of simulated neurointerventions with regular and reduced radiation doses using a standard flat panel detector system. MATERIALS AND METHODS: Ten 3D-printed intracranial aneurysm models were generated on the basis of a single patient vasculature derived from intracranial DSA and CTA. The incident dose to each model was reduced using a 0.7-mm-thick copper attenuator with a circular ROI hole (10-mm diameter) in the middle mounted inside the Infinix C-arm. Each model was treated twice with a primary coiling intervention using ROI-dose-reduced intervention and regular-dose intervention protocols. Eighty images acquired at various intervention stages were shown twice to 2 neurointerventionalists who independently scored imaging qualities (visibility of aneurysm-parent vessel morphology, associated vessels, and/or devices used). Dose-reduction measurements were performed using an ionization chamber. RESULTS: A total integral dose reduction of 62% per frame was achieved. The mean scores for regular-dose intervention and ROI dose-reduced intervention images did not differ significantly, suggesting similar image quality. Overall intrarater agreement for all scored criteria was substantial (Kendall τ = 0.62887; P < .001). Overall interrater agreement for all criteria was fair (κ = 0.2816; 95% CI, 0.2060–0.3571). CONCLUSIONS: Substantial dose reduction (62%) with a live peripheral image was achieved without compromising feature visibility during neuroendovascular interventions.
- 15 February 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (4) , 734-741
Open AccessA Patient Dose-Reduction Technique for Neuroendovascular Image-Guided Interventions: Image-Quality Comparison Study
BACKGROUND AND PURPOSE: The ROI–dose-reduced intervention technique represents an extension of ROI fluoroscopy combining x-ray entrance skin dose reduction with spatially different recursive temporal filtering to reduce excessive image noise in the dose-reduced periphery in real-time. The aim of our study was to compare the image quality of simulated neurointerventions with regular and reduced radiation doses using a standard flat panel detector system. MATERIALS AND METHODS: Ten 3D-printed intracranial aneurysm models were generated on the basis of a single patient vasculature derived from intracranial DSA and CTA. The incident dose to each model was reduced using a 0.7-mm-thick copper attenuator with a circular ROI hole (10-mm diameter) in the middle mounted inside the Infinix C-arm. Each model was treated twice with a primary coiling intervention using ROI-dose-reduced intervention and regular-dose intervention protocols. Eighty images acquired at various intervention stages were shown twice to 2 neurointerventionalists who independently scored imaging qualities (visibility of aneurysm-parent vessel morphology, associated vessels, and/or devices used). Dose-reduction measurements were performed using an ionization chamber. RESULTS: A total integral dose reduction of 62% per frame was achieved. The mean scores for regular-dose intervention and ROI dose-reduced intervention images did not differ significantly, suggesting similar image quality. Overall intrarater agreement for all scored criteria was substantial (Kendall τ = 0.62887; P < .001). Overall interrater agreement for all criteria was fair (κ = 0.2816; 95% CI, 0.2060–0.3571). CONCLUSIONS: Substantial dose reduction (62%) with a live peripheral image was achieved without compromising feature visibility during neuroendovascular interventions.