Application of the double relaxation oscillation superconducting quantum interference device sensor to micro-tesla 1H nuclear magnetic resonance experiments
- 1 September 2011
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 110 (5) , 053906
Abstract
We developed an ultra-low field (ULF)-nuclear magnetic resonance (NMR) measurement system capable of working with a measurement field (Bm) of several micro-tesla and performed basic NMR studies with a double relaxation oscillation superconducting quantum interference device (DROS) instead of conventional dc-SQUIDs. DROS is a SQUID sensor utilizing a relaxation oscillation between a dc-SQUID and a relaxation circuit; the new unit consists of an inductor and a resistor, and is connected in parallel with the SQUID. DROS has a 10 times larger flux-to-voltage transfer coefficient (∼mV/ϕ0) than that of the dc-SQUID, and this large transfer coefficient enables the acquisition of the SQUID signal with a simple flux-locked-loop (FLL) circuit using room temperature pre-amplifiers. The DROS second-order gradiometer showed average field noise of 9.2 μϕ0/√Hz in a magnetically shielded room (MSR). In addition, a current limiter formed of a Josephson junction array was put in a flux-transformer of DROS to prevent excessive currents that can be generated from the high pre-polarization field (Bp). Using this system, we measured an 1H NMR signal in water under 2.8 μT Bm field and reconstructed a one-dimensional MR image from the 1H NMR signal under a gradient field BG of 4.09 nT/mm. In addition, we confirmed that the ULF-NMR system can measure the NMR signal in the presence of metal without any distortion by measuring the NMR signal of a sample wrapped with metal. Lastly, we have measured the scalar J-coupling of trimethylphosphate and were able to confirm a clear doublet NMR signal with the coupling strength J3[P,H] = 10.4 ± 0.8 Hz. Finally, because the existing ULF-NMR/MRI studies were almost all performed with dc-SQUID based systems, we constructed a dc-SQUID-based ULF-NMR system in addition to the DROS based system and compared the characteristics of the two different systems by operating the two systems under identical experimental conditions.Keywords
This publication has 22 references indexed in Scilit:
- SQUID-based instrumentation for ultralow-field MRISuperconductor Science and Technology, 2007
- 64-channel magnetocardiogram system based on double relaxation oscillation SQUID planar gradiometersSuperconductor Science and Technology, 2006
- Advances in High-Field Magnetic Resonance ImagingAnnual Review of Biomedical Engineering, 2004
- Liquid-State NMR and Scalar Couplings in Microtesla Magnetic FieldsScience, 2002
- Low-Field MRI of Laser Polarized Noble GasPhysical Review Letters, 1998
- Double relaxation oscillation SQUID with reference junction for biomagnetic multichannel applicationsApplied Superconductivity, 1997
- Use of a DC SQUID receiver preamplifier in a low field MRI systemIEEE Transactions on Applied Superconductivity, 1995
- High sensitivity double relaxation oscillation superconducting quantum interference devices with large transfer from flux to voltageReview of Scientific Instruments, 1995
- (Double) relaxation oscillation SQUIDs with high flux-to-voltage transfer: Simulations and experimentsJournal of Applied Physics, 1994
- Nuclear magnetism of liquid systems in the earth field rangePhysics Reports, 1980