Independent component analysis (ICA) applied to dynamic oxygen‐enhanced MRI (OE‐MRI) for robust functional lung imaging at 3 T
Open Access
- 20 November 2023
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (3) , 955-971
Abstract
Purpose: Dynamic lung oxygen‐enhanced MRI (OE‐MRI) is challenging due to the presence of confounding signals and poor signal‐to‐noise ratio, particularly at 3 T. We have created a robust pipeline utilizing independent component analysis (ICA) to automatically extract the oxygen‐induced signal change from confounding factors to improve the accuracy and sensitivity of lung OE‐MRI.Methods: Dynamic OE‐MRI was performed on healthy participants using a dual‐echo multi‐slice spoiled gradient echo sequence at 3 T and cyclical gas delivery. ICA was applied to each echo within a thoracic mask. The ICA component relating to the oxygen‐enhancement signal was automatically identified using correlation analysis. The oxygen‐enhancement component was reconstructed, and the percentage signal enhancement (PSE) was calculated. The lung PSE of current smokers was compared with nonsmokers; scan–rescan repeatability, ICA pipeline repeatability, and reproducibility between two vendors were assessed.Results: ICA successfully extracted a consistent oxygen‐enhancement component for all participants. Lung tissue and oxygenated blood displayed the opposite oxygen‐induced signal enhancements. A significant difference in PSE was observed between the lungs of current smokers and nonsmokers. The scan–rescan repeatability and the ICA pipeline repeatability were good.Conclusion: The developed pipeline demonstrated sensitivity to the signal enhancements of the lung tissue and oxygenated blood at 3 T. The difference in lung PSE between current smokers and nonsmokers indicates a likely sensitivity to lung function alterations that may be seen in mild pathology, supporting future use of our methods in patient studies.Keywords
All Related Versions
Funding Information
- Wellcome / EPSRC Centre for Interventional and Surgical Sciences (203145/Z/16/Z)
This publication has 32 references indexed in Scilit:
- Independent component analysis: recent advancesPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2013
- Comparison of lung T2* during free‐breathing at 1.5 T and 3.0 T with ultrashort echo time imagingMagnetic Resonance in Medicine, 2011
- Oxygen-Enhanced MRI of the Lungs: Intraindividual Comparison Between 1.5 and 3 TeslaRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2011
- Quantitative MRI measurement of lung density must account for the change in T with lung inflationJournal of Magnetic Resonance Imaging, 2009
- Assessment of human pulmonary function using oxygen‐enhancedT1imaging in patients with cystic fibrosisMagnetic Resonance in Medicine, 2004
- Imaging lung function using rapid dynamic acquisition of T 1-maps during oxygen enhancementMagnetic Resonance Materials in Physics, Biology and Medicine, 2004
- Comparison of the dependence of blood R2 and R on oxygen saturation at 1.5 and 4.7 TeslaMagnetic Resonance in Medicine, 2002
- Fast and robust fixed-point algorithms for independent component analysisIEEE Transactions on Neural Networks, 1999
- Hypoxic Pulmonary Vasoconstriction in Human LungsAnesthesiology, 1997
- Microscopic susceptibility variation and transverse relaxation: Theory and experimentMagnetic Resonance in Medicine, 1994