Independent component analysis (ICA) applied to dynamic oxygen-enhanced MRI (OE-MRI) for robust functional lung imaging at 3 T
Preprint
Abstract
Purpose: Dynamic lung oxygen-enhanced MRI (OE-MRI) is challenging due to the presence of confounding signals and poor signal-to-noise ratio, particularly at 3 T. We have created a robust pipeline utilizing independent component analysis (ICA) to automatically extract the oxygen-induced signal change from confounding factors to improve the accuracy and sensitivity of lung OE-MRI. Methods: Dynamic OE-MRI was performed on healthy participants using a dual-echo multi- slice spoiled gradient echo sequence at 3 T and cyclical gas delivery. ICA was applied to each echo within a thoracic mask. The ICA component relating to the oxygen-enhancement signal was automatically identified using correlation analysis. The oxygen-enhancement component was reconstructed, and the percentage signal enhancement (PSE) was calculated. The lung PSE of current smokers was compared with non-smokers; scan-rescan repeatability, ICA pipeline repeatability, and reproducibility between two vendors, were assessed. Results: ICA successfully extracted a consistent oxygen-enhancement component for all participants. Lung tissue and oxygenated blood displayed opposite oxygen-induced signal enhancements. A significant difference in PSE was observed between the lungs of current smokers and non-smokers. The scan-rescan repeatability, and the ICA pipeline repeatability, were good. Conclusion: The developed pipeline demonstrated sensitivity to the signal enhancements of the lung tissue and oxygenated blood at 3 T. The difference in lung PSE between current smokers and non-smokers indicates a likely sensitivity to lung function alterations that may be seen in mild pathology, supporting future use of our methods in patient studies.Keywords
All Related Versions
- Published version: Magnetic Resonance in Medicine, 91 (3), 955.
This publication has 33 references indexed in Scilit:
- Independent component analysis: recent advancesPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2013
- Comparison of lung T2* during free‐breathing at 1.5 T and 3.0 T with ultrashort echo time imagingMagnetic Resonance in Medicine, 2011
- Oxygen-Enhanced MRI of the Lungs: Intraindividual Comparison Between 1.5 and 3 TeslaRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2011
- NWChem: A comprehensive and scalable open-source solution for large scale molecular simulationsComputer Physics Communications, 2010
- Quantitative MRI measurement of lung density must account for the change in T with lung inflationJournal of Magnetic Resonance Imaging, 2009
- Assessment of human pulmonary function using oxygen‐enhancedT1imaging in patients with cystic fibrosisMagnetic Resonance in Medicine, 2004
- Imaging lung function using rapid dynamic acquisition of T 1-maps during oxygen enhancementMagnetic Resonance Materials in Physics, Biology and Medicine, 2004
- Comparison of the dependence of blood R2 and R on oxygen saturation at 1.5 and 4.7 TeslaMagnetic Resonance in Medicine, 2002
- Fast and robust fixed-point algorithms for independent component analysisIEEE Transactions on Neural Networks, 1999
- Hypoxic Pulmonary Vasoconstriction in Human LungsAnesthesiology, 1997