Repeatability of Pachymetric Mapping Using Fourier Domain Optical Coherence Tomography in Corneas With Opacities
Authors:
- 1 April 2012
- journal article
- basic investigation
- Published by Wolters Kluwer Health in Cornea
- Vol. 31 (4) , 418-423
Abstract
Purpose To evaluate the repeatability of Fourier domain optical coherence tomography (OCT) pachymetric mapping in patients with corneal opacities and to assess the reliability of Fourier domain OCT with 830 nm wavelength as a pachymetric measurement tool in opaque corneas. Methods A Fourier domain OCT system was used to map the corneal thickness of patients with corneal scars or dystrophy. A retrospective study of a consecutive series was conducted. The repeatability was measured using pooled standard deviation of repeated measurements. A slit-scanning tomography device provided pachymetric mapping for comparison. Results Seventeen eyes of 12 patients with corneal scars (7 trauma and 3 post infection) or dystrophy (2 Reis–Bucklers and 5 granular dystrophy) were included. The posterior corneal boundary was detectable in all cases. The average corneal thickness measured by OCT was 536 ± 89 μm in central 2 mm area, 553 ± 76 μm in pericentral 2- to 5-mm area, and 508 ± 93 μm for the minimum corneal thickness. The slit-scanning tomography central corneal thickness, 433 ± 111 μm, was significantly lower than OCT readings (mean difference −91.1 ± 33.3 μm, P = 0.002). Repeatability of the OCT measurements was 2.1 μm centrally and 1.2 μm pericentrally. Conclusion Pachymetric mapping with Fourier domain OCT was highly repeatable. Fourier domain OCT is a reliable pachymetric tool in opaque corneas. In comparison, corneal thickness measured by the slit-scanning tomography is significantly thinner than those measured by the Fourier domain OCT in the presence of corneal opacities.Keywords
This publication has 17 references indexed in Scilit:
- Pachymetric mapping with Fourier-domain optical coherence tomographyJournal of Cataract & Refractive Surgery, 2010
- Central Corneal Thickness Measurements with Optical Coherence Tomography and Ultrasound Pachymetry in Healthy Subjects and in Patients after Photorefractive KeratectomyEuropean Journal of Ophthalmology, 2009
- Comparison of Central Corneal Thickness Measurements by Ultrasound Pachymetry, Konan Noncontact Optical Pachymetry, and Orbscan PachymetryCornea, 2008
- Comparative Study of Central Corneal Thickness Measurement with Slit-Lamp Optical Coherence Tomography and Visante Optical Coherence TomographyOphthalmology, 2008
- High-speed Optical Coherence Tomography of Corneal OpacitiesOphthalmology, 2007
- Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopiaJournal of Cataract & Refractive Surgery, 2007
- Corneal thickness measurement by confocal microscopy, ultrasound, and scanning slit methodsAmerican Journal of Ophthalmology, 2004
- Reliability of pachymetric measurements using orbscan after excimer refractive surgeryOphthalmology, 2003
- Precision and Reproducibility of Measurements of Human Corneal Thickness with Rapid Optical Low-Coherence Reflectometry (OLCR)Journal of Biomedical Optics, 1999
- Micron‐resolution ranging of cornea anterior chamber by optical reflectometryLasers in Surgery and Medicine, 1991