Evaluation of a Ventricular Assist Device
- 1 May 2012
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 58 (3) , 212-216
Abstract
Improved outcomes and quality of life of heart failure patients have been reported with the use of left ventricular assist devices (LVADs). However, little information exists regarding devices in patients undergoing radiation cancer treatment. Two HeartWare Ventricular Assist Device (HVAD) pumps were repeatedly irradiated with high intensity 18 MV x-rays to a dosage range of 64–75 Gy at a rate of 6 Gy/min from a radiation oncology particle accelerator to determine operational stability. Pump parameter data was collected through a data acquisition system. Second, a computerized tomography (CT) scan was taken of the device, and a treatment planning computer estimated characteristics of dose scattering and attenuation. Results were then compared with actual radiation measurements. The devices exhibited no changes in pump operation during the procedure, though the titanium components of the HVAD markedly attenuate the therapy beam. Computer modeling indicated an 11.8% dose change in the absorbed dosage that was distinctly less than the 84% dose change measured with detectors. Simulated and measured scattering processes were negligible. Computer modeling underestimates pretreatment dose to patients when the device is in the field of radiation. Future x-ray radiation dosimetry and treatment planning in HVAD patients should be carefully managed by radiation oncology specialists.Keywords
This publication has 8 references indexed in Scilit:
- Third INTERMACS Annual Report: The evolution of destination therapy in the United StatesThe Journal of Heart and Lung Transplantation, 2011
- X-ray Radiation Causes Electromagnetic Interference in Implantable Cardiac PacemakersPacing and Clinical Electrophysiology, 2010
- Continuous Flow Left Ventricular Assist Device Improves Functional Capacity and Quality of Life of Advanced Heart Failure PatientsJACC, 2010
- Establishing radiation therapy treatment planning effects involving implantable pacemakers and implantable cardioverter‐defibrillatorsJournal of Applied Clinical Medical Physics, 2009
- Extended Mechanical Circulatory Support With a Continuous-Flow Rotary Left Ventricular Assist DeviceJACC, 2009
- Dosimetric effects near implanted vascular access ports: an examination of external photon beam dose calculationsJournal of Applied Clinical Medical Physics, 2009
- Case study of radiation therapy treatment of a patient with a cardiac ventricular assist device∗Journal of Applied Clinical Medical Physics, 2008
- Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scalePhysics in Medicine & Biology, 2003