Jiaxin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiaxin Zhang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Anouk S. Verschuur
Department of Radiology, Isala Hospital
1 shared publication Chantal M.W. Tax
Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
1 shared publication- Daniel Le
Medical Imaging Master’s Programme, Utrecht University, 3584 CS Utrecht, The Netherlands
1 shared publication - Dimo Devetzis
Medical Imaging Master’s Programme, Utrecht University, 3584 CS Utrecht, The Netherlands
1 shared publication - Dingina M. Cornelissen
Medical Imaging Master’s Programme, Utrecht University, 3584 CS Utrecht, The Netherlands
1 shared publication - Eric Mathew Schrauben
Department of Radiology and Nuclear Medicine, Amsterdam UMC University of Amsterdam Amsterdam the Netherlands
1 shared publication
Latest Publications
- Open Access
Automated Segmentation of Intracranial Arteries on 4D Flow MRI for Hemodynamic Quantification
Accurate vessel segmentation is essential for reliable hemodynamic quantification in 4D Flow MRI. Automated segmentation with deep learning offers a promising alternative to the time-consuming, operator-dependent manual segmentation, but its application is often hindered by the scarcity of labeled datasets. Moreover, while a previous study has evaluated the impact of automated vs manual segmentation on downstream intracranial hemodynamic quantification, it remains to be explored whether variability between different automated segmentation methods affects hemodynamic quantification significantly, particularly in the context of intracranial 7T 4D Flow MRI. We investigated a transfer learning–based intracranial artery segmentation model using a 3D full-resolution nnU-Net, pretrained on 355 TOF-MRA scans and fine-tuned on 11 7T 4D Flow MRI scans. The model was compared with two published models: a direct-transfer U-Net pretrained only on TOF-MRA without 4D Flow MRI fine-tuning, and a DenseNet U-Net trained from scratch on the same 11 7T 4D Flow MRI scans. Segmentation performance was evaluated against the manual reference on test sets with different resolutions and the impact on downstream hemodynamic quantification was assessed. The transfer learning–based nnU-Net achieved the highest Dice score (>0.85), the lowest HD95 (∼3 mm), and the highest ICCs in cross-sectional area (0.62–0.87, except PCAs) and mean blood flow (0.78– 0.98). For wall shear stress (WSS) quantification, the transfer learning–based nnU-Net segmentations achieved the closest agreement with the manual reference (mean = 1.57 ± 0.63 Pa, ICC = 0.96; max = 2.16 ± 1.05 Pa, ICC = 0.97) and minimal bias (≤ 1.7%), whereas U-Net and DenseNet U-Net showed systematic under-(−5%) and overestimation (+7%), respectively. However, several vessel segments, including the ACA for DenseNet U-Net and the BA for U-Net, showed statistically significant differences (ANOVA post-hoc correction P < 0.05) in the flow-related metrics when compared with the manual reference. These results suggest that a transfer learning–based nnU-Net can provide accurate automated intracranial artery segmentation for 7T 4D Flow MRI. Differences among automated segmentation pipelines and associated analysis regions were linked to differences in downstream hemodynamic estimates.
Open AccessAutomated Segmentation of Intracranial Arteries on 4D Flow MRI for Hemodynamic Quantification
Accurate vessel segmentation is essential for reliable hemodynamic quantification in 4D Flow MRI. Automated segmentation with deep learning offers a promising alternative to the time-consuming, operator-dependent manual segmentation, but its application is often hindered by the scarcity of labeled datasets. Moreover, while a previous study has evaluated the impact of automated vs manual segmentation on downstream intracranial hemodynamic quantification, it remains to be explored whether variability between different automated segmentation methods affects hemodynamic quantification significantly, particularly in the context of intracranial 7T 4D Flow MRI. We investigated a transfer learning–based intracranial artery segmentation model using a 3D full-resolution nnU-Net, pretrained on 355 TOF-MRA scans and fine-tuned on 11 7T 4D Flow MRI scans. The model was compared with two published models: a direct-transfer U-Net pretrained only on TOF-MRA without 4D Flow MRI fine-tuning, and a DenseNet U-Net trained from scratch on the same 11 7T 4D Flow MRI scans. Segmentation performance was evaluated against the manual reference on test sets with different resolutions and the impact on downstream hemodynamic quantification was assessed. The transfer learning–based nnU-Net achieved the highest Dice score (>0.85), the lowest HD95 (∼3 mm), and the highest ICCs in cross-sectional area (0.62–0.87, except PCAs) and mean blood flow (0.78– 0.98). For wall shear stress (WSS) quantification, the transfer learning–based nnU-Net segmentations achieved the closest agreement with the manual reference (mean = 1.57 ± 0.63 Pa, ICC = 0.96; max = 2.16 ± 1.05 Pa, ICC = 0.97) and minimal bias (≤ 1.7%), whereas U-Net and DenseNet U-Net showed systematic under-(−5%) and overestimation (+7%), respectively. However, several vessel segments, including the ACA for DenseNet U-Net and the BA for U-Net, showed statistically significant differences (ANOVA post-hoc correction P < 0.05) in the flow-related metrics when compared with the manual reference. These results suggest that a transfer learning–based nnU-Net can provide accurate automated intracranial artery segmentation for 7T 4D Flow MRI. Differences among automated segmentation pipelines and associated analysis regions were linked to differences in downstream hemodynamic estimates.
- Open Access
- 17 September 2025
- Published by MDPI AG in Healthcare
- Vol. 13 (18) , 2327
Quantification of Thoracic Volume and Spinal Length of Pediatric Scoliosis Patients on Chest MRI Using a 3D U-Net Segmentation
Background/Objectives: Adolescent idiopathic scoliosis (AIS) can lead to significant chest deformations. The quantification of chest deformity and spinal length could provide additional insights for monitoring during follow-up and treatment. This study proposes a 3D U-Net convolutional neural network (CNN) for automatic thoracic and spinal segmentations of chest MRI scans. Methods: In this proof-of-concept study, axial chest MRI scans from 19 girls aged 8–10 years at risk for AIS development and 19 asymptomatic young adults were acquired (n = 38). The thoracic volume and spine were manually segmented as the ground truth (GT). A 3D U-Net CNN was trained on 31 MRI scans. The seven remaining MRI scans were used for validation, reported by the Dice similarity coefficient (DSC), the Hausdorff distance (HD), precision, and recall. From these segmentations, the thoracic volume and 3D spinal length were calculated. Results: Automatic chest segmentation was possible for all chest MRIs. For the chest volume segmentations, the average DSC was 0.91, HD was 51.89, precision was 0.90, and recall 0.99. For the spinal segmentation, the average DSC was 0.85, HD was 25.98, precision was 0.74, and recall 0.99. Chest volumes and 3D spinal lengths differed by on average 11% and 12% between automatic and GT, respectively. Qualitative analysis showed agreement between the automatic and manual segmentations in most cases. Conclusions: The proposed 3D U-Net CNN shows a high accuracy and good predictions in terms of HD, DSC, precision, and recall. This suggested 3D U-Net CNN could potentially be used to monitor the progression of chest deformation in scoliosis patients in a radiation-free manner. Improvement can be made by training the 3D U-net with more data and improving the GT data.
- 17 September 2025
- Published by MDPI AG in Healthcare
- Vol. 13 (18) , 2327
Open AccessQuantification of Thoracic Volume and Spinal Length of Pediatric Scoliosis Patients on Chest MRI Using a 3D U-Net Segmentation
Background/Objectives: Adolescent idiopathic scoliosis (AIS) can lead to significant chest deformations. The quantification of chest deformity and spinal length could provide additional insights for monitoring during follow-up and treatment. This study proposes a 3D U-Net convolutional neural network (CNN) for automatic thoracic and spinal segmentations of chest MRI scans. Methods: In this proof-of-concept study, axial chest MRI scans from 19 girls aged 8–10 years at risk for AIS development and 19 asymptomatic young adults were acquired (n = 38). The thoracic volume and spine were manually segmented as the ground truth (GT). A 3D U-Net CNN was trained on 31 MRI scans. The seven remaining MRI scans were used for validation, reported by the Dice similarity coefficient (DSC), the Hausdorff distance (HD), precision, and recall. From these segmentations, the thoracic volume and 3D spinal length were calculated. Results: Automatic chest segmentation was possible for all chest MRIs. For the chest volume segmentations, the average DSC was 0.91, HD was 51.89, precision was 0.90, and recall 0.99. For the spinal segmentation, the average DSC was 0.85, HD was 25.98, precision was 0.74, and recall 0.99. Chest volumes and 3D spinal lengths differed by on average 11% and 12% between automatic and GT, respectively. Qualitative analysis showed agreement between the automatic and manual segmentations in most cases. Conclusions: The proposed 3D U-Net CNN shows a high accuracy and good predictions in terms of HD, DSC, precision, and recall. This suggested 3D U-Net CNN could potentially be used to monitor the progression of chest deformation in scoliosis patients in a radiation-free manner. Improvement can be made by training the 3D U-net with more data and improving the GT data.