A method for improving the stability and accuracy of active magnetic compensation system for magnetic shielding rooms
- 13 May 2026
- journal article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (23)
Abstract
Active magnetic compensation (AMC) technology contributes to the realization of an extremely weak magnetic environment in magnetic shielding rooms (MSR), which is of great significance for measuring biomagnetic signal using an optically pumped magnetometer (OPM) sensor. However, sensor delay degrades the stability of the AMC system, while random magnetic field disturbances impair control accuracy. An active disturbance rejection control method combined with filtered Smith predictor (ADRC-FSP) is proposed to effectively compensate for sensor delay while suppressing random magnetic field disturbances. First, the structure of the AMC system is analyzed, and a mathematical model is established. Then, considering the action path of random disturbances, an ADRC-FSP is designed. Finally, simulations and experiments verify the effectiveness of proposed method, demonstrating improved system stability and a 34.9% increase in compensation accuracy. It has an important contribution to the measurement of biomagnetic signals.Keywords
Funding Information
- National Natural Science Foundation of China (42388101)
- National Natural Science Foundation of China (62225301)
- National Natural Science Foundation of China (62303032)
- National Natural Science Foundation of China (62573027)
- China Postdoctoral Science Foundation (2025M783639)
This publication has 22 references indexed in Scilit:
- Smith predictor based control of multi time-delay processesAnnual Reviews in Control, 2025
- Magnetic shielding mechanism and structure design of composites at low frequency: A reviewJournal of Magnetism and Magnetic Materials, 2023
- Mouth magnetoencephalography: A unique perspective on the human hippocampusNeuroImage, 2021
- Robust filtered Smith predictor for processes with time-varying delay: A simplified stability approachEuropean Journal of Control, 2020
- On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometersNeuroImage, 2019
- 3 Magnetocardiography Using a Novel Analysis System (Cardioflux) in the Evaluation of Emergency Department Observation Unit Chest Pain PatientsAnnals of Emergency Medicine, 2018
- Moving magnetoencephalography towards real-world applications with a wearable systemNature, 2018
- Measuring MEG closer to the brain: Performance of on-scalp sensor arraysNeuroImage, 2017
- EEG and MEG: Relevance to NeuroscienceNeuron, 2013
- Unified approach for robust dead-time compensator designJournal of Process Control, 2009