Haoan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haoan Wang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Haitao Li
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
4 shared publications - Haifeng Zhang
School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, China
3 shared publications - Jinji Sun
Beihang University
3 shared publications - Shiqiang Zheng
Beihang University
2 shared publications - Xikai Liu
Ningbo Institute of Technology, Beihang University, Ningbo 315800, China; Zhejiang Engineering Research Center of Precision Electromagnetic Control Technology and Equipment, Ningbo 315800, China
2 shared publications - Ximing Liu
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
2 shared publications
Latest Publications
- 13 May 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (23)
A method for improving the stability and accuracy of active magnetic compensation system for magnetic shielding rooms
Active magnetic compensation (AMC) technology contributes to the realization of an extremely weak magnetic environment in magnetic shielding rooms (MSR), which is of great significance for measuring biomagnetic signal using an optically pumped magnetometer (OPM) sensor. However, sensor delay degrades the stability of the AMC system, while random magnetic field disturbances impair control accuracy. An active disturbance rejection control method combined with filtered Smith predictor (ADRC-FSP) is proposed to effectively compensate for sensor delay while suppressing random magnetic field disturbances. First, the structure of the AMC system is analyzed, and a mathematical model is established. Then, considering the action path of random disturbances, an ADRC-FSP is designed. Finally, simulations and experiments verify the effectiveness of proposed method, demonstrating improved system stability and a 34.9% increase in compensation accuracy. It has an important contribution to the measurement of biomagnetic signals.
- 13 May 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (23)
A method for improving the stability and accuracy of active magnetic compensation system for magnetic shielding rooms
Active magnetic compensation (AMC) technology contributes to the realization of an extremely weak magnetic environment in magnetic shielding rooms (MSR), which is of great significance for measuring biomagnetic signal using an optically pumped magnetometer (OPM) sensor. However, sensor delay degrades the stability of the AMC system, while random magnetic field disturbances impair control accuracy. An active disturbance rejection control method combined with filtered Smith predictor (ADRC-FSP) is proposed to effectively compensate for sensor delay while suppressing random magnetic field disturbances. First, the structure of the AMC system is analyzed, and a mathematical model is established. Then, considering the action path of random disturbances, an ADRC-FSP is designed. Finally, simulations and experiments verify the effectiveness of proposed method, demonstrating improved system stability and a 34.9% increase in compensation accuracy. It has an important contribution to the measurement of biomagnetic signals.
- 13 February 2026
- Published by Elsevier in Control Engineering Practice
- Vol. 170
Dual-coil active disturbance rejection control for compact MEG measurement systems
- 13 February 2026
- Published by Elsevier in Control Engineering Practice
- Vol. 170
Dual-coil active disturbance rejection control for compact MEG measurement systems
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Spatial Magnetic Field Equalization Compensation of Magnetic Shielding Rooms Based on Multisensor Feedback
Active magnetic compensation (AMC) is essential for maintaining a stable near-zero magnetic environment and improving the signal-to-noise ratio of magnetoencephalography (MEG) measurements based on optically pumped magnetometers (OPMs). However, reducing the overall magnetic field noise level within the uniform area in MEG measurements remains a challenging issue for low-cost miniaturized magnetic shielding rooms (MSRs). This work proposes a spatial magnetic field equalization (SMFE) method based on multi-sensor feedback that addresses two key challenges in spatial magnetic field compensation: sensor delay and weight allocation. First, the active magnetic field compensation system is modeled, and a sensor delay compensation scheme based on the gain-adaptive Smith predictor is established to improve the parameter margin and system performance. Then, the layout of the sensors is designed and the multi-sensor weight allocation scheme is optimized to achieve the spatial magnetic field equalization compensation. Finally, simulation and experimental results on miniaturized MSR demonstrate the effectiveness of the proposed method.
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Spatial Magnetic Field Equalization Compensation of Magnetic Shielding Rooms Based on Multisensor Feedback
Active magnetic compensation (AMC) is essential for maintaining a stable near-zero magnetic environment and improving the signal-to-noise ratio of magnetoencephalography (MEG) measurements based on optically pumped magnetometers (OPMs). However, reducing the overall magnetic field noise level within the uniform area in MEG measurements remains a challenging issue for low-cost miniaturized magnetic shielding rooms (MSRs). This work proposes a spatial magnetic field equalization (SMFE) method based on multi-sensor feedback that addresses two key challenges in spatial magnetic field compensation: sensor delay and weight allocation. First, the active magnetic field compensation system is modeled, and a sensor delay compensation scheme based on the gain-adaptive Smith predictor is established to improve the parameter margin and system performance. Then, the layout of the sensors is designed and the multi-sensor weight allocation scheme is optimized to achieve the spatial magnetic field equalization compensation. Finally, simulation and experimental results on miniaturized MSR demonstrate the effectiveness of the proposed method.
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (8) , 12842-12851
Two-Stage Compensation System Based on Decoupled Biplanar Coils for Near-Zero Magnetic Field Environments
To achieve the near-zero magnetic field environment necessary for magnetoencephalography (MEG) measurements, a two-stage magnetic compensation (TMC) system for background magnetic field compensation in a magnetic shielding room (MSR) is proposed in this paper. The TMC system utilizes Decoupled Biplanar Coils (DBCs) to create two types of regions in MSR: uniform and decoupled regions. In the first stage, Helmholtz coil is arranged outside the MSR and a fluxgate for the measurement is placed in the decoupled region where the current in the DBC coil does not generate a magnetic field. Compensation in this stage can decrease residual magnetic field and guarantee optically pumped magnetometers (OPMs) function within the spin-exchange relaxation-free (SERF) regime. In the second stage, DBCs inside the MSR use OPMs for closed-loop feedback, generating spatially uniform magnetic fields. The TMC system effectively reduces residual and peak magnetic fields within the MSR, providing a suitable background magnetic field for magnetoencephalography (MEG) measurements.
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (8) , 12842-12851
Two-Stage Compensation System Based on Decoupled Biplanar Coils for Near-Zero Magnetic Field Environments
To achieve the near-zero magnetic field environment necessary for magnetoencephalography (MEG) measurements, a two-stage magnetic compensation (TMC) system for background magnetic field compensation in a magnetic shielding room (MSR) is proposed in this paper. The TMC system utilizes Decoupled Biplanar Coils (DBCs) to create two types of regions in MSR: uniform and decoupled regions. In the first stage, Helmholtz coil is arranged outside the MSR and a fluxgate for the measurement is placed in the decoupled region where the current in the DBC coil does not generate a magnetic field. Compensation in this stage can decrease residual magnetic field and guarantee optically pumped magnetometers (OPMs) function within the spin-exchange relaxation-free (SERF) regime. In the second stage, DBCs inside the MSR use OPMs for closed-loop feedback, generating spatially uniform magnetic fields. The TMC system effectively reduces residual and peak magnetic fields within the MSR, providing a suitable background magnetic field for magnetoencephalography (MEG) measurements.
- 7 February 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (3) , 036102
Compensation of complex environmental magnetic field disturbances for biomagnetic field measurements
Background magnetic field compensation can effectively improve the signalto-noise ratio of biomagnetic field measurements. But for complex environmental disturbances, creating a stable near-zero magnetic field environment is a challenging topic. Therefore, this paper constructs a background magnetic field compensation system based on the Improved Linear Expanded State Observer (ILESO), which effectively reduces the magnetic field fluctuations. Firstly, the system model is obtained based on the input and output characteristics of the system. Then, an improved linear extended state observer is designed to observe and compensate the environmental disturbance, and the adaptive rate is established to balance the estimation capability of the observer and the measurement noise. Finally, the experimental results validate the effectiveness of the proposed method. For 1 Hz disturbances, the peak-to-peak magnetic field value was reduced from 3.71 nT to 0.33 nT. Under the influence of external environmental magnetic field disturbances with an amplitude of 3417 nT within the 0–15 Hz frequency band, the internal magnetic field within the magnetic shielding room remains consistently stable within 1 nT. These results have a significant reference for obtaining an ultra-stable, near-zero environment.
- 7 February 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (3) , 036102
Compensation of complex environmental magnetic field disturbances for biomagnetic field measurements
Background magnetic field compensation can effectively improve the signalto-noise ratio of biomagnetic field measurements. But for complex environmental disturbances, creating a stable near-zero magnetic field environment is a challenging topic. Therefore, this paper constructs a background magnetic field compensation system based on the Improved Linear Expanded State Observer (ILESO), which effectively reduces the magnetic field fluctuations. Firstly, the system model is obtained based on the input and output characteristics of the system. Then, an improved linear extended state observer is designed to observe and compensate the environmental disturbance, and the adaptive rate is established to balance the estimation capability of the observer and the measurement noise. Finally, the experimental results validate the effectiveness of the proposed method. For 1 Hz disturbances, the peak-to-peak magnetic field value was reduced from 3.71 nT to 0.33 nT. Under the influence of external environmental magnetic field disturbances with an amplitude of 3417 nT within the 0–15 Hz frequency band, the internal magnetic field within the magnetic shielding room remains consistently stable within 1 nT. These results have a significant reference for obtaining an ultra-stable, near-zero environment.
- 31 January 2023
- Published by Springer Nature
- p. 2607-2616
Moving-Gimbal Effect Suppression of MSCMG Based on Fractional-Order Disturbance Observer
- 31 January 2023
- Published by Springer Nature
- p. 2607-2616
Moving-Gimbal Effect Suppression of MSCMG Based on Fractional-Order Disturbance Observer