Impact of the Speed of Airflow in a Cleanroom on the Degree of Air Pollution
Open Access
- 26 February 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 12 (5) , 2466
Abstract
The high-energy requirements of cleanrooms are the main motivation for optimizing their operational conditions. The ventilation system consumes the most energy in order to ensure the precise air conditioning of the room (filtration, temperature, and humidity adjustment). The main function of the ventilation system is to keep particle concentration to a minimum. This work deals with the optimization of an experimental operating room via the optimization of air supply through the distribution element (laminar airflow ceiling) in the range of 0.15–0.25 m·s−1. The laminar airflow between the distribution element and the patient is influenced by the operating light and different airflow velocities. These factors affect changes in particle concentration. Ansys Fluent software was used to investigate the nature of the flow, velocity profiles, and particle trajectories. The results of our numerical simulation demonstrate that a suitable flow rate setting increases the efficiency of particle reduction in the operating table area by up to 54%, which can, in turn, reduce operating costs. The simulated air velocity profile was subsequently verified using the particle image velocimetry (PIV) method. The typical size of particles monitored for in cleanrooms is 0.5 μm according to ISO EN 7. Therefore, the results of this study should be helpful in correctly designing distribution elements for clean rooms.Keywords
Funding Information
- Agentúra na Podporu Výskumu a Vývoja (APVV PP-COVID-20-0113)
- European Regional Development Fund (ITMS2014+ code 313011ASK8)
This publication has 37 references indexed in Scilit:
- An experimental study on the influences of air change rate and free area ratio of raised-floor on cleanroom particle concentrationsBuilding and Environment, 2012
- Dispersion of coughed droplets in a fully-occupied high-speed rail cabinBuilding and Environment, 2012
- Characterization of minienvironments in a clean room: Design characteristics and environmental performanceBuilding and Environment, 2007
- Numerical Investigation of Particle Diffusion in a Clean RoomIndoor and Built Environment, 2005
- Power consumption of semiconductor fabs in TaiwanEnergy, 2003
- A Procedure for Verification, Validation, and Reporting of Indoor Environment CFD AnalysesHVAC&R Research, 2002
- Design and evaluation of a minienvironment for semiconductor manufacture processesBuilding and Environment, 2002
- The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutantsJournal of Exposure Science & Environmental Epidemiology, 2001
- Two-equation eddy-viscosity turbulence models for engineering applicationsAIAA Journal, 1994
- Assessment and Analysis of the Bellows Ventilation of ClothingTextile Research Journal, 1973