Jonathan M. Cannata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jonathan M. Cannata has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
E. S. Kim
University of Southern California 3 Department of Electrical Engineering and Electrophysics Los Angeles, California 90089, USA
2 shared publicationsH. Yu
Arizona State University 2 Department of Electrical Engineering, School of Earth and Space Exploration Tempe, Arizona 85287, USA
2 shared publicationsJ. A. Williams
University of Southern California 1 NIH Resource Center for Medical Ultrasonic Transducer Technology, Department of Biomedical Engineering Los Angeles, California 90089, USA
2 shared publicationsK. K. Shung
University of Southern California 1 NIH Resource Center for Medical Ultrasonic Transducer Technology, Department of Biomedical Engineering Los Angeles, California 90089, USA
2 shared publicationsK. Kirk Shung
Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California USA
2 shared publicationsK.K. Shung
2 shared publications
Latest Publications
- Open Access
- 1 November 2012
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 31 (11) , 1795-1802
Development of a Flexible Implantable Sensor for Postoperative Monitoring of Blood Flow
We have developed a blood flow measurement system using Doppler ultrasound flow sensors fabricated of thin and flexible piezoelectric‐polymer films. These flow sensors can be wrapped around a blood vessel and accurately measure flow. The innovation that makes this flow sensor possible is the diffraction‐grating transducer. A conventional transducer produces a sound beam perpendicular to its face; therefore, when placed on the wall of a blood vessel, the Doppler shift in the backscattered ultrasound from blood theoretically would be 0. The diffraction‐grating transducer produces a beam at a known angle to its face; therefore, backscattered ultrasound from the vessel will contain a Doppler signal. Flow sensors were fabricated by spin coating a poly(vinylidene fluoride–trifluoroethylene) copolymer film onto a flexible substrate with patterned gold electrodes. Custom‐designed battery‐operated continuous wave Doppler electronics along with a laptop computer completed the system. A prototype flow sensor was evaluated experimentally by measuring blood flow in a flow phantom and the infrarenal aorta of an adult New Zealand White rabbit. The flow phantom experiment demonstrated that the error in average velocity and volume blood flow was less than 6% for 30 measurements taken over a 2.5‐hour period. The peak blood velocity through the rabbit infrarenal aorta measured by the flow sensor was 118 cm/s, within 1.7% of the measurement obtained using a duplex ultrasound system. The flow sensor and electronics operated continuously during the course of the 5‐hour experiment after the incision on the animal was closed.
- 1 November 2012
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 31 (11) , 1795-1802
Open AccessDevelopment of a Flexible Implantable Sensor for Postoperative Monitoring of Blood Flow
We have developed a blood flow measurement system using Doppler ultrasound flow sensors fabricated of thin and flexible piezoelectric‐polymer films. These flow sensors can be wrapped around a blood vessel and accurately measure flow. The innovation that makes this flow sensor possible is the diffraction‐grating transducer. A conventional transducer produces a sound beam perpendicular to its face; therefore, when placed on the wall of a blood vessel, the Doppler shift in the backscattered ultrasound from blood theoretically would be 0. The diffraction‐grating transducer produces a beam at a known angle to its face; therefore, backscattered ultrasound from the vessel will contain a Doppler signal. Flow sensors were fabricated by spin coating a poly(vinylidene fluoride–trifluoroethylene) copolymer film onto a flexible substrate with patterned gold electrodes. Custom‐designed battery‐operated continuous wave Doppler electronics along with a laptop computer completed the system. A prototype flow sensor was evaluated experimentally by measuring blood flow in a flow phantom and the infrarenal aorta of an adult New Zealand White rabbit. The flow phantom experiment demonstrated that the error in average velocity and volume blood flow was less than 6% for 30 measurements taken over a 2.5‐hour period. The peak blood velocity through the rabbit infrarenal aorta measured by the flow sensor was 118 cm/s, within 1.7% of the measurement obtained using a duplex ultrasound system. The flow sensor and electronics operated continuously during the course of the 5‐hour experiment after the incision on the animal was closed.
- 10 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 58 (10) , 2202-2212
A high-frequency linear ultrasonic array utilizing an interdigitally bonded 2-2 piezo-composite
This paper describes the development of a high-frequency 256-element linear ultrasonic array utilizing an interdigitally bonded (IB) piezo-composite. Several IB composites were fabricated with different commercial and experimental piezoelectric ceramics and evaluated to determine a suitable formulation for use in high-frequency linear arrays. It was found that the fabricated fine-scale 2-2 IB composites outperformed 1-3 IB composites with identical pillar- and kerf-widths. This result was not expected and lead to the conclusion that dicing damage was likely the cause of the discrepancy. Ultimately, a 2-2 composite fabricated using a fine-grain piezoelectric ceramic was chosen for the array. The composite was manufactured using one IB operation in the azimuth direction to produce approximately 19-μm-wide pillars separated by 6-μm-wide kerfs. The array had a 50 μm (one wavelength in water) azimuth pitch, two matching layers, and 2 mm elevation length focused to 7.3 mm using a polymethylpentene (TPX) lens. The measured pulse-echo center frequency for a representative array element was 28 MHz and -6-dB bandwidth was 61%. The measured single-element transmit -6-dB directivity was estimated to be 50°. The measured insertion loss was 19 dB after compensating for the effects of attenuation and diffraction in the water bath. A fine-wire phantom was used to assess the lateral and axial resolution of the array when paired with a prototype system utilizing a 64-channel analog beamformer. The -6-dB lateral and axial resolutions were estimated to be 125 and 68 μm, respectively. An anechoic cyst phantom was also imaged to determine the minimum detectable spherical inclusion, and thus the 3-D resolution of the array and beamformer. The minimum anechoic cyst detected was approximately 300 μm in diameter.
- 10 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 58 (10) , 2202-2212
A high-frequency linear ultrasonic array utilizing an interdigitally bonded 2-2 piezo-composite
This paper describes the development of a high-frequency 256-element linear ultrasonic array utilizing an interdigitally bonded (IB) piezo-composite. Several IB composites were fabricated with different commercial and experimental piezoelectric ceramics and evaluated to determine a suitable formulation for use in high-frequency linear arrays. It was found that the fabricated fine-scale 2-2 IB composites outperformed 1-3 IB composites with identical pillar- and kerf-widths. This result was not expected and lead to the conclusion that dicing damage was likely the cause of the discrepancy. Ultimately, a 2-2 composite fabricated using a fine-grain piezoelectric ceramic was chosen for the array. The composite was manufactured using one IB operation in the azimuth direction to produce approximately 19-μm-wide pillars separated by 6-μm-wide kerfs. The array had a 50 μm (one wavelength in water) azimuth pitch, two matching layers, and 2 mm elevation length focused to 7.3 mm using a polymethylpentene (TPX) lens. The measured pulse-echo center frequency for a representative array element was 28 MHz and -6-dB bandwidth was 61%. The measured single-element transmit -6-dB directivity was estimated to be 50°. The measured insertion loss was 19 dB after compensating for the effects of attenuation and diffraction in the water bath. A fine-wire phantom was used to assess the lateral and axial resolution of the array when paired with a prototype system utilizing a 64-channel analog beamformer. The -6-dB lateral and axial resolutions were estimated to be 125 and 68 μm, respectively. An anechoic cyst phantom was also imaged to determine the minimum detectable spherical inclusion, and thus the 3-D resolution of the array and beamformer. The minimum anechoic cyst detected was approximately 300 μm in diameter.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (1094687X) , 1913-1917
A family of intracardiac ultrasound imaging devices designed for guidance of electrophysiology ablation procedures
Our Bioengineering Research Partnership grant, ldquoHigh Frequency Ultrasound Arrays for Cardiac Imagingrdquo, including the individuals cited at the end of this paper - Douglas N. Stephens (UC Davis), Matthew O'Donnell (UW Seattle), Kai Thomenius (GE Global Research), Aaron M. Dentinger (GE Global Research), Douglas Wildes (GE Global Research), Peter Chen (St. Jude Medical), K. Kirk Shung (University of Southern California), Jonathan M. Cannata (University of Southern California), Butrus (Pierre) T. Khuri-Yakub (Stanford University), Omer Oralkan (Stanford University), Aman Mahajan (UCLA School of Medicine), Kalyanam Shivkumar (UCLA School of Medicine) and David J. Sahn (Oregon Health & Science University) - is in its sixth year of NIH funding, having proposed to develop a family of high frequency miniaturized forward and side-looking ultrasound imaging devices equipped with electrophysiology mapping and localization sensors and eventually to include a family of capacitive micromachined ultrasonic transducer (cMUT) devices - a forward-looking cMUT MicroLinear array and a ring array capable of 3-dimensional imaging and a 5Fr lumen large enough to admit an electrode and ablation devices.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (1094687X) , 1913-1917
A family of intracardiac ultrasound imaging devices designed for guidance of electrophysiology ablation procedures
Our Bioengineering Research Partnership grant, ldquoHigh Frequency Ultrasound Arrays for Cardiac Imagingrdquo, including the individuals cited at the end of this paper - Douglas N. Stephens (UC Davis), Matthew O'Donnell (UW Seattle), Kai Thomenius (GE Global Research), Aaron M. Dentinger (GE Global Research), Douglas Wildes (GE Global Research), Peter Chen (St. Jude Medical), K. Kirk Shung (University of Southern California), Jonathan M. Cannata (University of Southern California), Butrus (Pierre) T. Khuri-Yakub (Stanford University), Omer Oralkan (Stanford University), Aman Mahajan (UCLA School of Medicine), Kalyanam Shivkumar (UCLA School of Medicine) and David J. Sahn (Oregon Health & Science University) - is in its sixth year of NIH funding, having proposed to develop a family of high frequency miniaturized forward and side-looking ultrasound imaging devices equipped with electrophysiology mapping and localization sensors and eventually to include a family of capacitive micromachined ultrasonic transducer (cMUT) devices - a forward-looking cMUT MicroLinear array and a ring array capable of 3-dimensional imaging and a 5Fr lumen large enough to admit an electrode and ablation devices.
- 15 April 2008
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 103 (8) , 084109-841094
Self-focused ZnO transducers for ultrasonic biomicroscopy
A simple fabrication technique was developed to produce high frequency self-focused single element transducers with sputtered zinc oxide (ZnO) crystal films. This technique requires the sputtering of a ZnO film directly onto a curved backing substrate. Transducers were fabricated by sputtering an thick ZnO layer on diameter aluminum rods with ends shaped and polished to produce a focus or f-number equal to one. The aluminum rod served a dual purpose as the backing layer and positive electrode for the resultant transducers. A Parylene matching layer was deposited on the transducers after housing and interconnect. This matching layer was used to protect the substrate and condition the transfer of acoustic energy between the ZnO film and the load medium. The pulse-echo response for a representative transducer was centered at with a bandwidth of 49%. The measured two way insertion loss was . A tungsten wire phantom and an adult zebrafish eye were imaged to show the capability of these transducers.- 15 April 2008
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 103 (8) , 084109-841094
Self-focused ZnO transducers for ultrasonic biomicroscopy
A simple fabrication technique was developed to produce high frequency self-focused single element transducers with sputtered zinc oxide (ZnO) crystal films. This technique requires the sputtering of a ZnO film directly onto a curved backing substrate. Transducers were fabricated by sputtering an thick ZnO layer on diameter aluminum rods with ends shaped and polished to produce a focus or f-number equal to one. The aluminum rod served a dual purpose as the backing layer and positive electrode for the resultant transducers. A Parylene matching layer was deposited on the transducers after housing and interconnect. This matching layer was used to protect the substrate and condition the transfer of acoustic energy between the ZnO film and the load medium. The pulse-echo response for a representative transducer was centered at with a bandwidth of 49%. The measured two way insertion loss was . A tungsten wire phantom and an adult zebrafish eye were imaged to show the capability of these transducers.- 1 October 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 103 (10510117) , 945-948
10F-3 Self-Focused ZnO Transducers for Ultrasonic Biomicroscopy
A simple fabrication technique was developed to produce self-focused high frequency single element transducers with sputtered zinc oxide (ZnO) crystal films. The novelty of this technique lies in that the ZnO film can be sputtered directly onto a curved substrate. Two transducers were fabricated by sputtering an 18 mum thick ZnO layer on 2 and 3 mm diameter aluminum rods with ends shaped and polished to produce an f# equal to one. The aluminum rod served a dual purpose as the backing layer and positive electrode for the resultant transducers. A single 4 mum Parylene polymer matching layer was deposited on the transducers after housing and interconnect. The pulse-echo response for the 2 mm aperture transducer was centered at 109 MHz with a -6 dB bandwidth of 43%. A 3 mm aperture transducer produced a 96 MHz echo response with a 52% bandwidth. The measured insertion loss for the 2 mm aperture was 45 dB and the 3 mm aperture was 42 dB. A wire phantom and adult zebrafish were imaged to show the capability of the transducers.
- 1 October 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 103 (10510117) , 945-948
10F-3 Self-Focused ZnO Transducers for Ultrasonic Biomicroscopy
A simple fabrication technique was developed to produce self-focused high frequency single element transducers with sputtered zinc oxide (ZnO) crystal films. The novelty of this technique lies in that the ZnO film can be sputtered directly onto a curved substrate. Two transducers were fabricated by sputtering an 18 mum thick ZnO layer on 2 and 3 mm diameter aluminum rods with ends shaped and polished to produce an f# equal to one. The aluminum rod served a dual purpose as the backing layer and positive electrode for the resultant transducers. A single 4 mum Parylene polymer matching layer was deposited on the transducers after housing and interconnect. The pulse-echo response for the 2 mm aperture transducer was centered at 109 MHz with a -6 dB bandwidth of 43%. A 3 mm aperture transducer produced a 96 MHz echo response with a 52% bandwidth. The measured insertion loss for the 2 mm aperture was 45 dB and the 3 mm aperture was 42 dB. A wire phantom and adult zebrafish were imaged to show the capability of the transducers.
- 6 February 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 53 (1) , 224-236
Development of a 35-MHz piezo-composite ultrasound array for medical imaging
This paper discusses the development of a 64-element 35-MHz composite ultrasonic array. This array was designed primarily for ocular imaging applications, and features 2-2 composite elements mechanically diced out of a fine-grain high-density Navy Type VI ceramic. Array elements were spaced at a 50-micron pitch, interconnected via a custom flexible circuit and matched to the 50-ohm system electronics via a 75-ohm transmission line coaxial cable. Elevation focusing was achieved using a cylindrically shaped epoxy lens. One functional 64-element array was fabricated and tested. Bandwidths averaging 55%, 23-dB insertion loss, and crosstalk less than -24 dB were measured. An image of a tungsten wire target phantom was acquired using a synthetic aperture reconstruction algorithm. The results from this imaging test demonstrate resolution exceeding 50 /spl mu/m axially and 100 /spl mu/m laterally.
- 6 February 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 53 (1) , 224-236
Development of a 35-MHz piezo-composite ultrasound array for medical imaging
This paper discusses the development of a 64-element 35-MHz composite ultrasonic array. This array was designed primarily for ocular imaging applications, and features 2-2 composite elements mechanically diced out of a fine-grain high-density Navy Type VI ceramic. Array elements were spaced at a 50-micron pitch, interconnected via a custom flexible circuit and matched to the 50-ohm system electronics via a 75-ohm transmission line coaxial cable. Elevation focusing was achieved using a cylindrically shaped epoxy lens. One functional 64-element array was fabricated and tested. Bandwidths averaging 55%, 23-dB insertion loss, and crosstalk less than -24 dB were measured. An image of a tungsten wire target phantom was acquired using a synthetic aperture reconstruction algorithm. The results from this imaging test demonstrate resolution exceeding 50 /spl mu/m axially and 100 /spl mu/m laterally.
- Top Cited Papers
- 8 December 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 50 (11) , 1548-1557
Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications
This paper discusses the design, fabrication, and testing of sensitive broadband lithium niobate (LiNbO/sub 3/) single-element ultrasonic transducers in the 20-80 MHz frequency range. Transducers of varying dimensions were built for an f# range of 2.0-3.1. The desired focal depths were achieved by either casting an acoustic lens on the transducer face or press-focusing the piezoelectric into a spherical curvature. For designs that required electrical impedance matching, a low impedance transmission line coaxial cable was used. All transducers were tested in a pulse-echo arrangement, whereby the center frequency, bandwidth, insertion loss, and focal depth were measured. Several transducers were fabricated with center frequencies in the 20-80 MHz range with the measured -6 dB bandwidths and two-way insertion loss values ranging from 57 to 74% and 9.6 to 21.3 dB, respectively. Both transducer focusing techniques proved successful in producing highly sensitive, high-frequency, single-element, ultrasonic-imaging transducers. In vivo and in vitro ultrasonic backscatter microscope (UBM) images of human eyes were obtained with the 50 MHz transducers. The high sensitivity of these devices could possibly allow for an increase in depth of penetration, higher image signal-to-noise ratio (SNR), and improved image contrast at high frequencies when compared to previously reported results.
- 8 December 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 50 (11) , 1548-1557
Top Cited PapersDesign of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications
This paper discusses the design, fabrication, and testing of sensitive broadband lithium niobate (LiNbO/sub 3/) single-element ultrasonic transducers in the 20-80 MHz frequency range. Transducers of varying dimensions were built for an f# range of 2.0-3.1. The desired focal depths were achieved by either casting an acoustic lens on the transducer face or press-focusing the piezoelectric into a spherical curvature. For designs that required electrical impedance matching, a low impedance transmission line coaxial cable was used. All transducers were tested in a pulse-echo arrangement, whereby the center frequency, bandwidth, insertion loss, and focal depth were measured. Several transducers were fabricated with center frequencies in the 20-80 MHz range with the measured -6 dB bandwidths and two-way insertion loss values ranging from 57 to 74% and 9.6 to 21.3 dB, respectively. Both transducer focusing techniques proved successful in producing highly sensitive, high-frequency, single-element, ultrasonic-imaging transducers. In vivo and in vitro ultrasonic backscatter microscope (UBM) images of human eyes were obtained with the 50 MHz transducers. The high sensitivity of these devices could possibly allow for an increase in depth of penetration, higher image signal-to-noise ratio (SNR), and improved image contrast at high frequencies when compared to previously reported results.