A novel method for evaluating the thickness and keratometry profiles of toric lenticules created by a new-generation keratorefractive lenticule extraction platform
- 22 July 2026
- journal article
- research article
- Published by Springer Nature in Eye
- Vol. 40 (15) , 2410-2416
Abstract
Purpose To investigate the thickness and keratometry profiles of toric lenticules created by keratorefractive lenticule extraction (KLEx) using the VISUMAX 800 femtosecond laser platform. Methods This prospective study included the right eyes of 42 patients who underwent KLEx with VISUMAX 800 for correction of myopia and myopic astigmatism. Custom software generated spatial profiles of lenticule thickness (LT) and surgically-induced change in keratometry (SIK) based on raw pre- and postoperative tomographic data. The following indices were calculated: lenticule thickness per unit dioptre (LT/D), LT at the steep and flat meridians and their difference (LTF-S), percentage of lenticule thickness decrease (PLTD) and SIK at the steep and flat meridians. Results A significant difference in average LT/D was observed across optical zones (OZ), with LT/D with OZ increasing non-linearly with OZs. The lenticule exhibited a convex shape, thinning more rapidly towards the periphery. Flat LT/D exceeded steep LT/D and the difference (LTF-S) correlated positively with cylindrical error. Flat PLTD was lower than steep PLTD, indicating a slower rate of thickness decrease along the flat axis. Steep SIK exceeded flat SIK within the central 1–2 mm but was lower than flat SIK from 4 to 7 mm. Conclusions The spatial profiles of LT and SIK reflect the toric treatment module for astigmatic correction. This study introduces a method for in vivo measurement of lenticular spatial profiles, enabling quantitative assessment of lenticule geometry.Keywords
This publication has 29 references indexed in Scilit:
- The outcomes of first-generation (visumax 500) and second-generation (Visumax 800) keratorefractive lenticule extraction surgeries for astigmatismScientific Reports, 2024
- Comparison of early visual outcomes after SMILE using VISUMAX 800 and VISUMAX 500 for myopia: a retrospective matched case–control studyScientific Reports, 2024
- Refractive outcomes of small lenticule extraction (SMILE) Pro® with a 2 MHz femtosecond laserInternational Ophthalmology, 2024
- Stromal keratophakia: Corneal inlay implantationProgress in Retinal and Eye Research, 2020
- Decentration measurements using Placido corneal tangential curvature topography and Scheimpflug tomography pachymetry difference maps after small-incision lenticule extractionJournal of Cataract & Refractive Surgery, 2019
- Femtosecond Intrastromal Lenticular Implantation Combined With Accelerated Collagen Cross-Linking for the Treatment of Keratoconus—Initial Clinical Result in 6 EyesCornea, 2015
- Corneal pachymetry: New ways to look at an old measurementJournal of Cataract & Refractive Surgery, 2014
- Corneal tissue ablation depth and the Munnerlyn formulaJournal of Cataract & Refractive Surgery, 2003
- Three-dimensional representation and qualitative comparisons of the amount of tissue ablation to treat mixed and compound astigmatismJournal of Cataract & Refractive Surgery, 2002
- Photorefractive keratectomy: A technique for laser refractive surgeryJournal of Cataract & Refractive Surgery, 1988