X-ray to MR: the progress of flexible instruments for endovascular navigation
Open Access
- 1 July 2021
- journal article
- review article
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 3 (3) , 032004
Abstract
Interventional radiology and cardiology are rapidly growing areas of minimally invasive surgery, covering multiple diagnostic and interventional procedures. Treatment via endovascular techniques has become the go-to approach, thanks to its minimally invasive nature and its effectiveness in reducing hospitalisation and total time to recovery when compared to open surgery. Although x-ray fluoroscopy is currently the gold standard imaging technique for endovascular interventions, it presents occupational safety hazards to medical personnel and potential risks to patients, especially paediatric patients, because of its inherent ionising radiation. Magnetic resonance imaging (MRI), with its unique ability to provide radiation-free imaging, and acquiring morphologic and functional information, holds great promise in the advancement of image-guided navigation through the vasculature. Moreover, MRI has the potential to combine diagnosis, therapy and early evaluation of therapy in the same intervention. However, MR-guided interventions face a major challenge due to the presence of a large magnetic field (1.5/3 Tesla), which limits the set of materials suitable for the construction of key instrumentation (sheaths, catheters and guidewires). Despite these challenges, in recent years, significant progress has been made in the development of interventional devices, which comprise biocompatible, MR safe and MR visible materials. In an attempt to encourage and accelerate the development of MR-guided endovascular instrumentation, we present a systematic and illustrated overview of the plethora of work targeting to overcome the aforementioned limitations which are underpinned by the interdependent advancements in science, technology, engineering, mathematics and medicine (STEMM).Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/P012779)
This publication has 197 references indexed in Scilit:
- Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology ProceduresJournal of Visualized Experiments, 2013
- MRI active guidewire with an embedded temperature probe and providing a distinct tip signal to enhance clinical safetyJournal of Cardiovascular Magnetic Resonance, 2012
- Remote control catheter navigation: options for guidance under MRIJournal of Cardiovascular Magnetic Resonance, 2012
- A deflectable guiding catheter for real‐time MRI‐guided interventionsJournal of Magnetic Resonance Imaging, 2011
- Steerable Catheter Microcoils for Interventional MRIAcademic Radiology, 2011
- Comparison of Magnetic Navigation System and Conventional Method in Catheter Ablation of Atrial Fibrillation: Is Magnetic Navigation System Is More Effective and Safer Than Conventional Method?Korean Circulation Journal, 2011
- Active two‐channel 0.035″ guidewire for interventional cardiovascular MRIJournal of Magnetic Resonance Imaging, 2009
- Laser-machined shape memory alloy sensors for position feedback in active cathetersSensors and Actuators A: Physical, 2008
- MR‐guided intravascular interventions: Techniques and applicationsJournal of Magnetic Resonance Imaging, 2008
- Nephrogenic systemic fibrosis: a serious late adverse reaction to gadodiamideEuropean Radiology, 2006