Abstract
The purpose of this research was to investigate the impact of body mass index (BMI) on dose area product (DAP), effective dose (E), dose to the organs and image quality (IQ) on 200 patients referred to pelvic radiography. Patients were classified into three groups according to BMI: normal (30). The results showed 52% and 135% higher DAP for overweight and obese patients compared to normal-weight patients (p < 0.001). A 46 and 123% rise of E for overweight and obese patients compared to normal-weight patients (p < 0.001) was discovered. Overweight patients received 37% higher dose and obese patients 107% higher dose to the organs compared to normal-weight patients. There were no statistically significant differences between IQ, except between normal weight and overweight patients. A strong correlation (r = 0.733) was found between BMI and DAP and between BMI and E (r = 0.776).Keywords
This publication has 19 references indexed in Scilit:
- Estimation of adult patient doses for selected X-ray diagnostic examinationsJournal of Radiation Research and Applied Sciences, 2014
- Reduction of radiation risks in patients undergoing some X-ray examinations by using optimal projections: A Monte Carlo program-based mathematical calculationJournal of Medical Physics, 2014
- Severe Obesity is Associated With 3-Fold Higher Radiation Dose Rate During UreteroscopyUrology, 2013
- Obesity Triples the Radiation Dose of Stone Protocol Computerized TomographyJournal of Urology, 2013
- Duration of Fluoroscopic‐Guided Spine Interventions and Radiation Exposure Is Increased in Overweight PatientsPM&R, 2013
- The Relationship of Body Mass Index and Abdominal Fat on the Radiation Dose Received during Routine Computed Tomographic Imaging of the Abdomen and PelvisCanadian Association of Radiologists Journal, 2012
- Estimation of absorbed organ doses and effective dose based on body mass index in digital radiographyRadiation Protection Dosimetry, 2012
- Clinical factors increasing radiation doses to patients undergoing long-lasting procedures: Abdominal stent-graft implantationMedical Science Monitor, 2011
- Increased Radiation Dose to Overweight and Obese Patients from Radiographic ExaminationsRadiology, 2009
- Obesity Is a Major Determinant of Radiation Dose in Patients Undergoing Pulmonary Vein Isolation for Atrial FibrillationJACC, 2007