NZNika Zalokar

Nika Zalokar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nika Zalokar has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Nejc Mekiš

    Medical Imaging and Radiotherapy Department, Faculty of Health Sciences, University of Ljubljana, Ljubljana, Slovenia

    5 shared publications
  • Anja Resnik

    University of Ljubljana, Faculty of Health Sciences, Department of Medical Imaging and Radiotherapy, Zdravstvena pot 5, 1000 Ljubljana, Slovenia

    1 shared publication
  • Erna Alukic

    University of Ljubljana, Faculty of Health Sciences, Medical Imaging and Radiotherapy Department, Zdravstvena Pot 5, 1000 Ljubljana, Slovenia

    1 shared publication
  • Valerija Žager Marciuš

    University of Ljubljana, Faculty of Health Sciences, Medical Imaging and Radiotherapy Department, Zdravstvena pot 5, 1000, Ljubljana, Slovenia; Institute of Oncology Ljubljana, Teleradiotherapy Department, Zaloška cesta 2, 1000 Ljubljana, Slovenia

    1 shared publication
  • Šejla Trožić

    University Medical Centre Ljubljana, Institute of Radiology, Zaloška 7, 1000, Ljubljana, Slovenia; University of Ljubljana, Faculty of Health Sciences, Medical Imaging and Radiotherapy Department, Zdravstvena Pot 5, 1000, Ljubljana, Slovenia

    1 shared publication

Latest Publications

  • OPTIMISATION OF RADIOGRAPHIC PROCEDURES – LUMBAR SPINE IMAGING IN GENERAL RADIOGRAPHY

    by Erna Alukic, Nika Zalokar, Nejc Mekiš

    Purpose: Any use of ionizing radiation must be justifi ed and the benefi t must be greater than the harm it causes. Imaging must be performed with the lowest possible dose received by the patient, while maintaining optimal radiographic image quality. Imaging of the lumbar spine is a relatively high dose imaging procedure. This systematic review aims to explore optimisation options to reduce patient exposure, while maintaining radiographic quality during plain lumbar spine imaging. Methods: A systematic review of the literature from the databases Pub Med Central, EBSCOhost including CINAHL, Cochrane Library, Web of Science, Science Direct, DiKUL and Springer Link was conducted. The documents were fully accessible and in the English language. Results: 26 experimental studies were included in the analysis. There are many optimisation methods: changing the tube potential, comparison of diff erent projections, use of shielding, primary beam collimation, increasing the source-to-image receptor distance, compression of the imaged area, using the air gap technique, evaluation of the need for additional projections, and rotating the patient depending on the tube side. On average, the dose is reduced by 44%. Studies that also evaluated the quality of radiographs found all radiographs to be diagnostically acceptable. Conclusion: The results confi rm a reasonable use of methods to optimize radiation exposure and to maintain an optimal image quality of radiographs. A systematic review for each specifi c area in general radiography should be conducted in the future. Keywords: lumbar spine imaging, optimisation, dose reduction, low dose, image quality


  • The efficiency of lead and non-lead shielding on breast dose in head CT

    by Šejla Trožić, Nejc Mekiš, Nika Zalokar

    The aim of the study was to assess the effect of the shielding material and its thickness on the measured skin dose to the breasts during the CT examination of the head. The helical and axial head CT was performed on an anthropomorphic phantom (PBU 60). Two types of shielding were tested—lead and non-lead (antimony-bismuth) shielding. Measurements with different thicknesses were performed and the shielding efficiency of the materials was compared. Skin dose to the breasts was measured with an educational direct dosimeter (EDD-30). The shielding efficiency during both scanning protocols indicated an increased dose reduction with the thicker equivalent thickness in both shielding materials. Dose reduction was the highest at 0.5 mm equivalent thickness for both materials; lead shielding reduced the dose by 91% and 83%, the antimony-bismuth shielding by 90% and 86%, during the axial and helical head CT protocols, respectively. Statistically significant differences were found between the materials of the same equivalent thickness (0.175, 0.25 and 0.5 mm) during the helical protocol in favor of the antimony-bismuth shielding. During the axial protocol there were no statistically significant differences. Shielding of radiosensitive organs can prevent unnecessary exposure of radiosensitive organs outside the primary beam. Due to the significant decrease in radiation dose to the breasts, and many other positive attributes, use of the antimony-bismuth shielding instead of the lead shielding should be considered, especially during the helical CT scan of the head.


  • RADIATION DOSE DURING PELVIC RADIOGRAPHY IN RELATION TO BODY MASS INDEX

    by Nika Zalokar, Anja Resnik, Nejc Mekiš

    The purpose of this research was to investigate the impact of body mass index (BMI) on dose area product (DAP), effective dose (E), dose to the organs and image quality (IQ) on 200 patients referred to pelvic radiography. Patients were classified into three groups according to BMI: normal (30). The results showed 52% and 135% higher DAP for overweight and obese patients compared to normal-weight patients (p < 0.001). A 46 and 123% rise of E for overweight and obese patients compared to normal-weight patients (p < 0.001) was discovered. Overweight patients received 37% higher dose and obese patients 107% higher dose to the organs compared to normal-weight patients. There were no statistically significant differences between IQ, except between normal weight and overweight patients. A strong correlation (r = 0.733) was found between BMI and DAP and between BMI and E (r = 0.776).


  • A PHANTOM STUDY SHOWING THE IMPORTANCE OF BREAST SHIELDING DURING HEAD CT

    by Nika Zalokar, Nejc Mekiš

    This study aimed to investigate the dose to the breasts during head computed tomography (CT) if lead shielding is used. The study was performed in two major hospitals using helical and axial protocols on an anthropomorphic phantom. Measurements were performed with and without the use of a lead shield of 0.5 mm equivalent density. The results showed a significant decrease in dose with the lead shielding in both hospitals. During the helical protocol, the use of shielding significantly reduced the dose by 96% in Hospital A and 82% in Hospital B. The dose reduction during axial protocol was also significant: 95% in Hospital A and 86% in Hospital B with lead shielding. Considering the significant dose reduction of 82% up to 96% during this study, we highly recommend the shielding of breasts regardless of the protocol used during head CT examinations.