An optimization method for ITER radial x-ray camera line-of-sight design basing on Bayesian uncertainty analysis
- 25 April 2024
- journal article
- research article
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 66 (6) , 065010
Abstract
This paper presents a novel uncertainty optimization algorithm for the design of line-of-sight (LOS) systems used in tomographic inversion. By extending Gaussian process tomography from discrete pixel space to continuous function space through Bayesian inference, we introduce an uncertainty function and analyze its typical distributions. We develop an algorithm to minimize the uncertainty, which is then applied to optimize the LOS configuration of the internal camera in the ITER project. Uncertainty analysis and phantom testing are conducted to validate the effectiveness of the proposed algorithm. The results demonstrate improved accuracy and stability in tomographic reconstructions. This study contributes to the advancement of LOS design for tomographic inversion, offering a practical solution for optimizing diagnostic systems in complex experimental settings.Keywords
Funding Information
- National Science Foundation for Young Scientists of China (12005052)
- National Natural Science Foundation of China (12275071)
This publication has 22 references indexed in Scilit:
- Progress on final design of ITER radial X-ray cameraFusion Engineering and Design, 2021
- Current Research into Applications of Tomography for Fusion DiagnosticsJournal of Fusion Energy, 2018
- Gaussian process tomography for soft x-ray spectroscopy at WEST without equilibrium informationReview of Scientific Instruments, 2018
- Application of AXUV diode detectors at ASDEX UpgradeReview of Scientific Instruments, 2014
- Bayesian soft X-ray tomography using non-stationary Gaussian ProcessesReview of Scientific Instruments, 2013
- Introducing minimum Fisher regularisation tomography to AXUV and soft x-ray diagnostic systems of the COMPASS tokamakReview of Scientific Instruments, 2012
- Soft x-ray tomography for real-time applications: present status at Tore Supra and possible future developmentsReview of Scientific Instruments, 2012
- The maximum likelihood reconstruction method for JET neutron tomographyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008
- Preliminary design of the soft x-ray array tomographic diagnostic system for Korea Superconducting Tokamak Advanced Research (KSTAR) plasmasReview of Scientific Instruments, 2004
- Reconstruction of m=1 MHD modes from projectionsReview of Scientific Instruments, 1986