RTRaphael Tieulent

Raphael Tieulent

*This is an algorithmically generated author record based on publicly available information.

Raphael Tieulent has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • First results from testing of the full ITER hard x-ray monitor prototype on the ADITYA Upgrade tokamak

    by P. Nowak Vel Nowakowski, Santosh P. Pandya, D. Makowski, Y. Liu, R. Tieulent, J. Ghosh, K. Singh, S. Dolui, R. L. Tanna, H. Raj, et al.

    For the first time, the full prototype of the ITER Hard X-Ray (HXR) monitor (HXRM) system has been successfully tested in a tokamak environment during the experimental campaign in the ADITYA Upgrade tokamak located at the Institute for Plasma Research. Unlike conventional HXR diagnostic systems operating in the existing tokamaks, the ITER HXRM is uniquely designed for robustness. In the HXRM system, the UV (Ultraviolet) photons from the scintillator are guided by the optical components to the PMT (Photomultiplier Tube). This approach introduces significant optical attenuation that has a direct impact on the characteristics of the PMT signal. As a result, digital pulse processing algorithms and the I&C (Instrumentation and Control) electronics need reconsideration to work correctly. The initial validation of the HXRM system design was carried out in the laboratory at the Department of Microelectronics and Computer Science, Lodz University of Technology, where the full prototype of the ITER HXRM system was established. The laboratory test validated the design considerations and aided the development of the I&C components. However, the functionality of the system has never been tested in the tokamak environment. The HXRM prototype setup was integrated into the ADITYA Upgrade tokamak and operated during plasma discharges. The data obtained from the plasma discharge allowed verification of the I&C electronics and methodology of the signal transmission, as well as validation of the developed PMT signal simulations. Several test configurations have been tested on the ADITYA Upgrade tokamak, and the preliminary results and observations are reported herein.

  • X-ray tomographic measurement and modeling for inferring tungsten impurity distribution in WEST plasmas: A review

    by D. Mazon, M. Chernyshova, A. Jardin, Y. Peysson, A. Wojenski, J. Colnel, D. Guibert, T. Czarski, K. Malinowski, P. Linczuk, et al.

    Since the advent of tungsten walls in ITER, the problem of precisely reconstructing the distribution of tungsten (W) concentration in the plasma has become all the more relevant. Among the different possible approaches, those using x-ray measurements seem particularly promising. Indeed, essential plasma parameters can be inferred from x-ray line-integrated measurements such as magnetic equilibrium, electron temperature, concentration of impurities, and their spatial distribution after tomographic inversion. Despite being extremely rich in information, the access to continuous spectral measurements is nevertheless a technical challenge rarely implemented in actual tokamaks. In this work, we review recent work on different techniques dedicated to the inference of the W impurity distribution in WEST plasmas, based on x-ray tomography diagnostics with or without energy discrimination, in particular with semiconductor and gas detectors. For this purpose, synthetic diagnostic tools have been developed for the different used detectors to validate the measurements in the presence of partially ionized W impurities in the core plasma and provide prediction for future applications in ITER.


  • Advanced Simulation of ITER Core X-ray Crystal Spectroscopy

    by Xinyi Jin, Zhifeng Cheng, Junli Zhang, Wei Yan, Zhongyong Chen, Novimir Pablant, Lan Gao, Dian Lu, Martin O’mUllane, Raphael Tieulent, et al.

    X-Ray Simulation Analysis (XRSA) is an analytical ray-tracing mixed code developed specifically for the ITER Core X-Ray Crystal Spectroscopy (XRCS-Core) diagnostic, which employs a dual-reflection configuration incorporating multiple pre-reflectors made of Highly Oriented Pyrolytic Graphite (HOPG) and spherically curved analyzing crystals. The ITER XRCS-Core is designed for high spectral resolution measurement in specific wavelength ranges, including narrow bands around 1.354 Å for W64+, 2.19 Å for Xe51+, and 2.555 Å for Xe44+ and Xe47+, enabling diagnostic capability across a broad electron temperature range in the ITER plasma. XRSA facilitates efficient simulation of the spectral performance of this complex X-ray spectroscopic system. Recent updates to the XRSA code have incorporated two critical effects: auto-focusing, which specifically applies to HOPG, and polarization. These two effects are particularly important in the dual-reflection configuration used in the ITER XRCS-Core system to provide more accurate modeling results. Simulations conducted with the updated code demonstrate that polarization has a substantial impact on the performance of the dual-reflection system. Additionally, the combined influence of polarization and system layout introduces performance variations across channels through the same crystal.


  • Performance characterization of x-ray crystal spectroscopy highly oriented pyrolytic graphite reflectors based on x-ray diffractometry experiments

    by Dian Lu, Zhifeng Cheng, Tianlei Zhao, Lingxiong Yuan, Lan Gao, Jonathan Klabacha, Novimir Pablant, Raphael Tieulent, Zichao Lin, Yifei Jin, et al.

    The use of Highly Oriented Pyrolytic Graphite (HOPG) reflectors is often proposed in the design of X-ray Crystal Spectroscopy (XCS) diagnostic systems for the next-generation tokamak devices, including the ITER project. This study introduces an experimental study based on the X-Ray Diffractometry (XRD) method to evaluate the performance of HOPG reflectors. The experimental method provides both the angular responses and the reflectivities of the HOPG reflectors. A demonstrative XRD experiment is conducted, and the details of the experiment are introduced. This method enables precise studies on HOPG reflectors, facilitating the design of XCS diagnostic systems for future tokamaks.

  • Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

    by N. A. Pablant, Z. Cheng, M. O’mUllane, L. Gao, R. Barnsley, M. N. Bartlett, M. Bitter, E. Bourcart, G. V. Brown, M. De Bock, et al.

    A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe44+, Xe47+, and Xe51+, based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.


  • An optimization method for ITER radial x-ray camera line-of-sight design basing on Bayesian uncertainty analysis

    by Sen Xu, Tianbo Wang, Raphael Tieulent, Damien Colette, Didier Mazon, Geert Verdoolaege, Jiquan Li

    This paper presents a novel uncertainty optimization algorithm for the design of line-of-sight (LOS) systems used in tomographic inversion. By extending Gaussian process tomography from discrete pixel space to continuous function space through Bayesian inference, we introduce an uncertainty function and analyze its typical distributions. We develop an algorithm to minimize the uncertainty, which is then applied to optimize the LOS configuration of the internal camera in the ITER project. Uncertainty analysis and phantom testing are conducted to validate the effectiveness of the proposed algorithm. The results demonstrate improved accuracy and stability in tomographic reconstructions. This study contributes to the advancement of LOS design for tomographic inversion, offering a practical solution for optimizing diagnostic systems in complex experimental settings.


  • Open Access

    ALICE luminosity determination for Pb–Pb collisions at √s NN = 5.02 TeV

    by S. Acharya, D. Adamová, A. Adler, G. Aglieri Rinella, M. Agnello, N. Agrawal, Z. Ahammed, S. Ahmad, S.U. Ahn, I. Ahuja, et al.

    Luminosity determination within the ALICE experiment is based on the measurement, in van der Meer scans, of the cross sections for visible processes involving one or more detectors (visible cross sections). In 2015 and 2018, the Large Hadron Collider provided Pb–Pb collisions at a centre-of-mass energy per nucleon pair of √s NN = 5.02 TeV. Two visible cross sections, associated with particle detection in the Zero Degree Calorimeter (ZDC) and in the V0 detector, were measured in a van der Meer scan. This article describes the experimental set-up and the analysis procedure, and presents the measurement results. The analysis involves a comprehensive study of beam-related effects and an improved fitting procedure, compared to previous ALICE studies, for the extraction of the visible cross section. The resulting uncertainty of both the ZDC-based and the V0-based luminosity measurement for the full sample is 2.5%. The inelastic cross section for hadronic interactions in Pb–Pb collisions at √s NN = 5.02 TeV, obtained by efficiency correction of the V0-based visible cross section, was measured to be 7.67 ± 0.25 b, in agreement with predictions using the Glauber model.


  • Open Access

    Measurement of beauty-strange meson production in Pb–Pb collisions at sNN=5.02TeV via non-prompt Ds+ mesons

    by S. Acharya, D. Adamová, A. Adler, G. Aglieri Rinella, M. Agnello, N. Agrawal, Z. Ahammed, S. Ahmad, S.U. Ahn, I. Ahuja, et al.


  • Open Access

    Photoproduction of low-pT J/ψ from peripheral to central Pb–Pb collisions at 5.02 TeV

    by S. Acharya, D. Adamová, A. Adler, G. Aglieri Rinella, M. Agnello, N. Agrawal, Z. Ahammed, S. Ahmad, S.U. Ahn, I. Ahuja, et al.


  • Open Access

    Measurement of the production of (anti)nuclei in p–Pb collisions at sNN=8.16TeV

    by S. Acharya, D. Adamová, A. Adler, J. Adolfsson, G. Aglieri Rinella, M. Agnello, N. Agrawal, Z. Ahammed, S. Ahmad, S.U. Ahn, et al.