MRI of patients with implanted cardiac devices
Authors:
- 4 August 2017
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 47 (3) , 595-603
Abstract
Cardiac implanted electronic devices (CIEDs) have historically been regarded as a contraindication for performing magnetic resonance imaging (MRI), limiting the availability of this exam for large numbers of patients who may have otherwise benefited from the unique diagnostic capabilities of MRI. Interactions between CIEDs and the magnetic field associated with MRI systems have been documented, and include potential effects on CIED function, lead heating, and force/torque on the generator. Several device manufacturers have developed “MR‐Conditional” CIEDs with specific hardware and software design changes to optimize the device for the MR environment. However, a substantial body of evidence has been accumulating that suggests that MRI may be safely performed in patients with either conditional or nonconditional CIEDs. Institutional policies and procedures, including preexam screening and assessment by skilled electrophysiology personnel and intraexam monitoring, allow MRI to be safely performed in CIED patients, as evidenced by at least two, large multicenter prospective studies and multiple smaller, single‐institution studies. Cross‐departmental collaboration and a robust safety infrastructure at sites that perform MRI should allow for the safe imaging of CIED patients who have a clinical indication for the study, regardless of the conditionality status of the device.Level of Evidence: 5Technical Efficacy: Stage 5J. Magn. Reson. Imaging 2018;47:595–603.Keywords
This publication has 54 references indexed in Scilit:
- Magnetic Resonance Imaging in Patients with Recently Implanted PacemakersPacing and Clinical Electrophysiology, 2013
- ACR guidance document on MR safe practices: 2013Journal of Magnetic Resonance Imaging, 2013
- Quantitative Assessment of Artifacts on Cardiac Magnetic Resonance Imaging of Patients With Pacemakers and Implantable Cardioverter-DefibrillatorsCirculation: Cardiovascular Imaging, 2011
- Abandoned Pacemaker Leads Are a Potential Risk for Patients Undergoing MRIPacing and Clinical Electrophysiology, 2011
- Magnetic resonance imaging in patients with cardiac pacemakers: era of “MR Conditional” designsJournal of Cardiovascular Magnetic Resonance, 2011
- Lead Extraction Is Preferred for Lead Revisions and System Upgrades: When Less Is MoreCirculation: Arrhythmia and Electrophysiology, 2010
- Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extractionEP Europace, 2009
- Magnetic Resonance Imaging of Implantable Cardiac Rhythm Devices at 3.0 TeslaPacing and Clinical Electrophysiology, 2008
- Complexity of MRI induced heating on metallic leads: Experimental measurements of 374 configurationsBioMedical Engineering OnLine, 2008
- Effects of magnetic resonance imaging on cardiac pacemakers and electrodesAmerican Heart Journal, 1997