Manufacturing conditioned roughness and wear of biomedical oxide ceramics for all-ceramic knee implants
Open Access
- 1 January 2013
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 12 (1) , 84
Abstract
Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices.Keywords
This publication has 32 references indexed in Scilit:
- Prediction of contact conditions and theoretical roughness in manufacturing of complex implants by toric grinding toolsInternational Journal of Machine Tools and Manufacture, 2010
- A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplastyBioMedical Engineering OnLine, 2010
- Material and surface factors influencing backside fretting wear in total knee replacement tibial componentsJournal of Biomechanics, 2010
- Diamond Tools for the Grinding of Complex Ceramic Implant SurfacesAdvanced Materials Research, 2009
- ABRASIVE-BASED NANO-FINISHING TECHNIQUES: AN OVERVIEWMachining Science and Technology, 2008
- Bionische Oberflächengestaltung der Metall/Metall-Gleitpaarung in der Hüftendoprothetik Optimierung tribologischer Eigenschaften / Bionic surface design in metal on metal bearings for total hip arthroplasty – Optimization of tribological characteristicsBiomedical Engineering / Biomedizinische Technik, 2005
- Comparison of the Wear Properties of Polyethylene Plate in Total Knee Prostheses (TKP) using Different Femoral Component MaterialsKey Engineering Materials, 2003
- Why Are Total Knee Arthroplasties Failing Today?Clinical Orthopaedics and Related Research, 2002
- Influence of Apparent Pressure on Wear Behavior of Self‐Mated AluminaJournal of the American Ceramic Society, 2000
- The influence of sampling strategy on a circular feature in coordinate measurementsMeasurement, 1996