Automated detection of vertebral body misalignments in orthogonal kV and MV guided radiotherapy: application to a comprehensive retrospective dataset
Open Access
- 29 February 2024
- journal article
- research article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (2) , 025039
Abstract
Objective. In image-guided radiotherapy (IGRT), off-by-one vertebral body misalignments are rare but potentially catastrophic. In this study, a novel detection method for such misalignments in IGRT was investigated using densely-connected convolutional networks (DenseNets) for applications towards real-time error prevention and retrospective error auditing. Approach. A total of 4213 images acquired from 527 radiotherapy patients aligned with planar kV or MV radiographs were used to develop and test error-detection software modules. Digitally reconstructed radiographs (DRRs) and setup images were retrieved and co-registered according to the clinically applied alignment contained in the DICOM REG files. A semi-automated algorithm was developed to simulate patient positioning errors on the anterior-posterior (AP) and lateral (LAT) images shifted by one vertebral body. A DenseNet architecture was designed to classify either AP images individually or AP and LAT image pairs. Receiver-operator characteristic curves (ROC) and areas under the curves (AUC) were computed to evaluate the classifiers on test subsets. Subsequently, the algorithm was applied to the entire dataset in order to retrospectively determine the absolute off-by-one vertebral body error rate for planar radiograph guided RT at our institution from 2011–2021. Main results. The AUCs for the kV models were 0.98 for unpaired AP and 0.99 for paired AP-LAT. The AUC for the MV AP model was 0.92. For a specificity of 95%, the paired kV model achieved a sensitivity of 99%. Application of the model to the entire dataset yielded a per-fraction off-by-one vertebral body error rate of 0.044% [0.0022%, 0.21%] for paired kV IGRT including one previously unreported error. Significance. Our error detection algorithm was successful in classifying vertebral body positioning errors with sufficient accuracy for retrospective quality control and real-time error prevention. The reported positioning error rate for planar radiograph IGRT is unique in being determined independently of an error reporting system.Keywords
Funding Information
- Agency for Healthcare Research and Quality (RO1 HS026486)
This publication has 38 references indexed in Scilit:
- Deep learning‐based detection and classification of multi‐leaf collimator modeling errors in volumetric modulated radiation therapyJournal of Applied Clinical Medical Physics, 2023
- Development and multi‐institutional validation of a convolutional neural network to detect vertebral body mis‐alignments in 2D x‐ray setup imagesMedical Physics, 2023
- Medical physics practice guideline 4.b: Development, implementation, use and maintenance of safety checklistsJournal of Applied Clinical Medical Physics, 2023
- 3D deep convolution neural network for radiation pneumonitis prediction following stereotactic body radiotherapyJournal of Applied Clinical Medical Physics, 2022
- Development and interinstitutional validation of an automatic vertebral‐body misalignment error detector for cone‐beam CT‐guided radiotherapyMedical Physics, 2022
- Improving the Quality of Care in Radiation Oncology using Artificial IntelligenceClinical Oncology, 2022
- Human factor associations with safety events in radiation therapyJournal of Applied Clinical Medical Physics, 2021
- Error detection model developed using a multi‐task convolutional neural network in patient‐specific quality assurance for volumetric‐modulated arc therapyMedical Physics, 2021
- Refinement of Treatment Setup and Target Localization Accuracy Using Three-Dimensional Cone-Beam Computed Tomography for Stereotactic Body RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Error in the delivery of radiation therapy: Results of a quality assurance reviewInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005