Comparison of Countercurrent Flow Limitation Experiments Performed in Two Different Models of the Hot Leg of a Pressurized Water Reactor With Rectangular Cross Section
- 28 December 2010
- journal article
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 133 (5) , 052917
Abstract
In order to investigate the two-phase flow behavior during countercurrent flow limitation in the hot leg of a pressurized water reactor, two test models were built: one at the Kobe University and the other at the TOPFLOW test facility of Forschungszentrum Dresden-Rossendorf (FZD). Both test facilities are devoted to optical measurement techniques; therefore, a flat hot leg test section design was chosen. Countercurrent flow limitation (CCFL) experiments were performed, simulating the reflux condenser cooling mode appearing in some accident scenarios. The fluids used were air and water, both at room temperature. The pressure conditions were varied from atmospheric at Kobe to 3.0 bars absolute at TOPFLOW. According to the presented review of literature, very few data are available on flooding in channels with a rectangular cross section, and no experiments were performed in the past in such flat models of a hot leg. Commonly, the macroscopic effects of CCFL are represented in a flooding diagram, where the gas flow rate is plotted versus the discharge water flow rate, using the nondimensional superficial velocity (also known as Wallis parameter) as coordinates. However, the classical definition of the Wallis parameter contains the pipe diameter as characteristic length. In order to be able to perform comparisons with pipe experiments and to extrapolate to the power plant scale, the appropriate characteristic length should be determined. A detailed comparison of the test facilities operated at the Kobe University and at FZD is presented. With respect to the CCFL behavior, it is shown that the essential parts of the two hot leg test sections are very similar. This geometrical analogy allows us to perform meaningful comparisons. However, clear differences in the dimensions of the cross section ( in Kobe, at FZD) make it possible to point out the right characteristic length for hot leg models with rectangular cross sections. The hydraulic diameter, the channel height, and the Laplace critical wavelength (leading to the Kutateladze number) were tested. A comparison of our own results with similar experimental data and empirical correlations for pipes available in literature shows that the channel height is the characteristic length to be used in the Wallis parameter for channels with rectangular cross sections. However, some limitations were noticed for narrow channels, where CCFL is reached at lower gas fluxes, as already observed in small scale hot legs with pipe cross sections.
Keywords
This publication has 12 references indexed in Scilit:
- Assessment of RELAP5/MOD3.2.2γ against flooding database in horizontal-to-inclined pipesAnnals of Nuclear Energy, 2002
- Countercurrent gas–liquid flow in inclined and vertical ducts — I: Flow patterns, pressure drop characteristics and floodingInternational Journal of Multiphase Flow, 2000
- CCFL in hot legs and steam generators and its prediction with the CATHARE code1995
- Countercurrent Gas-Liquid Flow in a Pressurized Water Reactor Hot LegNuclear Science and Engineering, 1994
- Downcomer and tie plate countercurrent flow in the Upper Plenum Test Facility (UPTF)Nuclear Engineering and Design, 1992
- UPTF test results: First three separate effect testsNuclear Engineering and Design, 1988
- Scale effects on countercurrent gas-liquid flow in a horizontal tube connected to an inclined riserNuclear Engineering and Design, 1988
- Experimental study of counter-current two-phase flow in horizontal tube connected to inclined riser.Journal of Nuclear Science and Technology, 1986
- Flooding in tubes and annuliInternational Journal of Multiphase Flow, 1981
- The onset of slugging in horizontal stratified air-water flowInternational Journal of Multiphase Flow, 1973