CVChristophe Vallée

Christophe Vallée

*This is an algorithmically generated author record based on publicly available information.

Christophe Vallée has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Numerical simulations for steam–water CCFL tests using the 1/3 scale rectangular channel simulating a PWR hot leg

    by Yoichi Utanohara, Ikuo Kinoshita, Michio Murase, Dirk Lucas, Christophe Vallée, Akio Tomiyama


  • Comparison of Countercurrent Flow Limitation Experiments Performed in Two Different Models of the Hot Leg of a Pressurized Water Reactor With Rectangular Cross Section

    by Christophe Vallée, Tobias Seidel, Dirk Lucas, Akio Tomiyama, Michio Murase

    In order to investigate the two-phase flow behavior during countercurrent flow limitation in the hot leg of a pressurized water reactor, two test models were built: one at the Kobe University and the other at the TOPFLOW test facility of Forschungszentrum Dresden-Rossendorf (FZD). Both test facilities are devoted to optical measurement techniques; therefore, a flat hot leg test section design was chosen. Countercurrent flow limitation (CCFL) experiments were performed, simulating the reflux condenser cooling mode appearing in some accident scenarios. The fluids used were air and water, both at room temperature. The pressure conditions were varied from atmospheric at Kobe to 3.0 bars absolute at TOPFLOW. According to the presented review of literature, very few data are available on flooding in channels with a rectangular cross section, and no experiments were performed in the past in such flat models of a hot leg. Commonly, the macroscopic effects of CCFL are represented in a flooding diagram, where the gas flow rate is plotted versus the discharge water flow rate, using the nondimensional superficial velocity (also known as Wallis parameter) as coordinates. However, the classical definition of the Wallis parameter contains the pipe diameter as characteristic length. In order to be able to perform comparisons with pipe experiments and to extrapolate to the power plant scale, the appropriate characteristic length should be determined. A detailed comparison of the test facilities operated at the Kobe University and at FZD is presented. With respect to the CCFL behavior, it is shown that the essential parts of the two hot leg test sections are very similar. This geometrical analogy allows us to perform meaningful comparisons. However, clear differences in the dimensions of the cross section (H×W=150×10 mm2 in Kobe, 250×50 mm2 at FZD) make it possible to point out the right characteristic length for hot leg models with rectangular cross sections. The hydraulic diameter, the channel height, and the Laplace critical wavelength (leading to the Kutateladze number) were tested. A comparison of our own results with similar experimental data and empirical correlations for pipes available in literature shows that the channel height is the characteristic length to be used in the Wallis parameter for channels with rectangular cross sections. However, some limitations were noticed for narrow channels, where CCFL is reached at lower gas fluxes, as already observed in small scale hot legs with pipe cross sections.


  • Experimental CFD grade data for stratified two-phase flows

    by Christophe Vallée, Dirk Lucas, Matthias Beyer, Heiko Pietruske, Peter Schütz, Helmar Carl


  • Air/Water Counter-Current Flow Experiments in a Model of the Hot Leg of a Pressurized Water Reactor

    by Christophe Vallée, Deendarlianto, Matthias Beyer, Dirk Lucas, Helmar Carl

    Different scenarios of small break loss of coolant accident for pressurized water reactors (PWRs) lead to the reflux-condenser mode in which steam enters the hot leg from the reactor pressure vessel (RPV) and condenses in the steam generator. A limitation of the condensate backflow toward the RPV by the steam flowing in counter current could affect the core cooling and must be prevented. The simulation of counter-current flow limitation conditions, which is dominated by 3D effects, requires the use of a computational fluid dynamics (CFD) approach. These numerical methods are not yet mature, so dedicated experimental data are needed for validation purposes. In order to investigate the two-phase flow behavior in a complex reactor-typical geometry and to supply suitable data for CFD code validation, the “hot leg model” was built at Forschungszentrum Dresden-Rossendorf (FZD). This setup is devoted to optical measurement techniques, and therefore, a flat test-section design was chosen with a width of 50 mm. The test section outlines represent the hot leg of a German Konvoi PWR at a scale of 1:3 (i.e., 250 mm channel height). The test section is mounted between two separators, one simulating the RPV and the other is connected to the steam generator inlet chamber. The hot leg model is operated under pressure equilibrium in the pressure vessel of the TOPFLOW facility of FZD. The air/water experiments presented in this article focus on the flow structure observed in the region of the riser and of the steam generator inlet chamber at room temperature and pressures up to 3 bar. The performed high-speed observations show the evolution of the stratified interface and the distribution of the two-phase mixture (droplets and bubbles). The counter-current flow limitation was quantified using the variation in the water levels measured in the separators. A confrontation with the images indicates that the initiation of flooding coincides with the reversal of the flow in the horizontal part of the hot leg. Afterward, bigger waves are generated, which develop to slugs. Furthermore, the flooding points obtained from the experiments were compared with empirical correlations available in literature. A good overall agreement was obtained, while the zero penetration was found at lower values of the gaseous Wallis parameter compared with previous work. This deviation can be attributed to the rectangular cross section of the hot leg model.