MMMichio Murase

Michio Murase

*This is an algorithmically generated author record based on publicly available information.

Michio Murase has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Void Fraction and Interfacial Friction in Spherical Particle Beds under Stagnant Liquid Conditions

    by Michio Murase, Koji Nishida, Toshiya Takaki, Ryo Kurimoto, Kosuke Hayashi, Akio Tomiyama

    In this study, we measured pressure gradient dP/dz and void fraction αG in spherical particle beds with particle diameters of 4 and 8 mm under stagnant liquid conditions. We obtained an empirical correlation and its uncertainty for the void fraction by using the data reported by Tutu et al. (1984), Chikhi et al. (2016) and ours. The uncertainty of the obtained αG correlation was relatively small and ±2s = ±0.049 (where s is the standard deviation). However, the uncertainty band for the computed dP/dz was relatively large due to the uncertainty in the void fraction, ±2s = ±0.049. Effects of the interfacial friction Fi on computation of dP/dz were also discussed.

  • Heat Flux Correlations for Condensation From Steam and Air Mixtures on Vertical Flat Plates

    by Michio Murase, Toshiya Takaki

    In this study, heat fluxes qc for condensation from steam and air mixtures on vertical flat plates were evaluated by using existing experimental data and qc correlations, in order to provide one of boundary conditions for computational fluid dynamics (CFD) analysis in a primary containment vessel (PCV) of nuclear power plants during accident conditions. Existing qc,fc correlations for forced convection condensation overestimated or underestimated experimental data qc,exp measured with the CONAN facility, and a combination of the selected existing qc,fc correlation and the suction correction factor θC was proposed to obtain good agreement between the qc,cal values computed with the combination and the qc,exp values. For natural convection condensation, it was found that the qc,nc values were largely different between those measured in closed vessels with evaporation and condensation and in flow channels with decreasing the mixture velocity, and hence, the present evaluation focused on qc,nc obtained in the flow channels. It was also found that uncertainty became large when the qc,nc values were computed by changing the Sherwood number Shfc in the qc,fc correlation to Shnc for natural convection. The qc,exp values measured with the COPAIN facility were well expressed by the qc,nc correlation proposed by Corradini (Nucl. Technol., 64(2), pp. 186-195, 1984), but the published data were few. Therefore, collection of experimental or numerical qc,nc values is necessary in the future.


  • Open Access

    3×3ロッドバンドルにおける停滞水条件での壁面摩擦とボイド率

    by Michio Murase, Koji Nishida, Toshiya Takaki, Shin-Ichiro Kida, Ryo Kurimoto, Kosuke Hayashi, Akio Tomiyama

    The wall friction term in a one-dimensional model vanishes under the stagnant liquid conditions (i.e. the liquid volume flux JL = 0). Hence void fraction αG(ΔP) in rod bundles have been evaluated using measured pressure gradients dP/dz. However, effects of the wall friction term on αG(ΔP) have not been quantitatively evaluated. In this study, we therefore carried out air-water experiments using a 3×3 rod bundle under the conditions of JL = 0, and measured dP/dz and αG,exp with the closing valve method. We obtained the dimensionless wall friction force Fw* (= αG(ΔP)-αG,exp) from the measured dP/dz and αG,exp. The Fw* values were expressed by using the gas volume flux JG, because the liquid flow field was induced by the gas flow (i.e. JG). The difference between αG,exp and αG(ΔP) was reduced by half after αG(ΔP) was corrected using the obtained correlation for Fw*. The Fw* correlation was applied to existing αG(ΔP) data for 4×4 and 8×8 bundles, and effects of Fw* on the αG(ΔP) values were confirmed to be small in a large rod bundle due to the small wall area per unit fluid volume.


  • Numerical Simulation of Wall Condensation from a Superheated Steam and Air Mixture in a Vertical Pipe

    by Michio Murase, Yoichi Utanohara

    The objective of this study was to evaluate the effects of superheat on wall condensation from a steam and air mixture. We previously measured the radial and axial temperature profiles of a superheated steam-air mixture in a vertical pipe with a diameter of 49.5 mm and a cooling height of 610 mm. In this study, we carried out a numerical simulation for the previous measurements by using the computational fluid dynamics (CFD) code FLUENT, and evaluated the profiles of the mixture temperature Tg and steam mass fraction Xs. The profiles of Tg and the saturated temperature Ts obtained from Xs agreed well with those measured with superheated and saturated conditions, respectively. The validity of the correlation to evaluate a condensation heat flux qc (which was based on the gradient of Xs) was confirmed. Profiles of the dimensionless velocity u+, temperature T+, and steam mass fraction Ys+ were obtained, and they were compared with wall functions (i.e., the linear function for a viscous sublayer and the logarithmic law for a turbulent layer). The computed profile agreed with the wall function for u+, agreed relatively well with the wall function for T+, and agreed well with the correlation for Ys+ obtained from data measured with saturated steam-air conditions in the region of the turbulent layer.


  • Open Access

    Numerical simulation of experiments for wall condensation from mixtures of saturated steam and air in a vertical tube

    by Michio Murase, Yoichi Utanohara

    This study evaluates our previously proposed correlations for the wall condensation heat flux qc and the wall functions of dimensionless profiles for temperature of steam and air mixture Tg and steam mass fraction Xs. These correlations are expected to be used in computational fluid dynamics (CFD) analysis with coarse computation cells to evaluate thermal hydraulic behavior in containment vessels (CVs) of nuclear power plants under accident conditions. We carried out numerical simulations of experiments for wall condensation from mixtures of saturated steam and air in a vertical tube (diameter, 49.5 mm) by using the CFD code FLUENT, compared the simulated Tg and qc values with measured values, and evaluated the profiles of dimensionless mixture temperature T+ and steam mass fraction Ys+ which are used for wall functions in turbulent analyses with coarse computation cells. We determined the simulated Tg and qc values agreed with the measured values within uncertainties, but the decrease of qc in the flow direction was not well simulated. The computed T+ values were smaller than the measured values but almost within the uncertainty, and the computed Ys+ values agreed well with the measured values obtained from the assumption of the saturated conditions (i.e. Ts = Tg). These results confirmed that our previously proposed correlations for the qc and wall functions can be used in a CFD analysis with coarse computation cells.


  • COUNTERCURRENT GAS-LIQUID FLOW IN A BOILING WATER REACTOR CORE DURING POSTULATED LOSS-OF-COOLANT ACCIDENTS

    by M. Murase, H. Suzuki, Y. Katoaoka, S. Hatamiya

    Countercurrent gas-liquid flow in parallel vertical channels is theoretically and experimentally evaluated for a boiling system simulating a BWR core. The parallel channel models are applied to the LOCA analysis program, SAFER, and verified by Two Bundle Loop test analysis. Applying the parallel channel effects to the fuel bundle, water drain tubes with the restricted bottom ends are developed in order to mitigate CCFL at the core outlet.

  • Dimensionless Profiles of Temperature and Steam Mass Fraction in Flows of Steam-Air Mixtures on a Flat Plate

    by Michio Murase, Tomonori Suzuki, Yoichi Utanohara, Toshiya Takaki

    Wall functions are generally used in a turbulent analysis with a computational fluid dynamics (CFD) code and large computation cells. The logarithmic law based on the analogy between momentum, energy, and mass transfer is widely used in wall functions for turbulent flows, but its validity in the turbulent boundary layer has not been confirmed for dimensionless profiles of temperature and steam mass fraction in flows of steam and noncondensable gases. In this article, therefore, we evaluated dimensionless profiles of temperature and steam mass fraction in flows of steam and air on a flat plate by using existing data. From the heat and mass transfer equations at the condensation surface based on the gradient of temperature or steam mass fraction, we showed that the convection heat flux qconv (which is used for the definition of the dimensionless temperature T+) should include the term of condensate mass flux ms and that the dimensionless steam mass fraction Ys+ should be a function of the dimensionless distance y+ (= uτ y/ν where uτ is the friction velocity), the Schmidt number Sc and the air mass fraction (1−Xs). Values obtained from the newly defined T+ and Ys+ and the existing data agreed relatively well with the linear function near the viscous sublayer (a few data points were there) but were much smaller than the existing logarithmic law due to condensation in the turbulent boundary layer (i.e., mist generation). On the other hand, the T+ and Ys+ values obtained by using the local Nusselt number Nuy and the local Sherwood number Shy (which were proposed in our previous study), respectively, agreed well with the logarithmic law.


  • Prediction Method for Condensation Heat Transfer in the Presence of Noncondensable Gas for Computational Fluid Dynamics Applications

    by Michio Murase, Yoichi Utanohara, Akio Tomiyama

    The objective of this study was to present a prediction method for condensation heat transfer in the presence of non-condensable gas (air or nitrogen) for CFD (computational fluid dynamics) analyses, where physical quantities in the computational cells in contact with the structural wall are generally used. First by using existing temperature distributions T(y) in the turbulent boundary layer along a flat plate as functions of the distance y from the condensation surface, we evaluated the distribution of condensation heat flux qc,pre(y) from the gradient of steam concentration, we derived a modification factor η(y+) as a function of the dimensionless distance y+ to obtain a good agreement with qc,cal calculated by the qc correlation defined by using the bulk quantities; and we obtained qc,mod(y)/qc,cal = 0.90-1.10 for the region of y+ > 17. Second we modified the local Sherwood number Sh(x) for flat plates for the boundary layer thickness d and obtained the function Sh(d). An existing qc correlation for flat plates as a function of Sh(d) was applied to predict the distribution of the local value qc,pre(y), and qc,pre(y)/qc,cal = 0.95-1.15 in the best case was obtained for the region of y+ > 30. Finally a correlation of the local Sherwood number Sh(y) was derived from the temperature distributions T(y) as a function of the local Reynolds number Re(y).


  • Open Access

    鉛直管内でのフラッディング状態における管内流動特性

    by Naoki Sano, Raito Goda, Kosuke Hayashi, Michio Murase, Akio Tomiyama

    Counter-current flow limitation (CCFL), the void fraction α, the wall friction factor fw, and the interfacial friction factor fi depend on the shapes of the top and bottom ends of vertical pipes, i.e., the sharp top end and round bottom end (SR), round top end and sharp bottom end (RS), and round top and bottom ends (RR). We observed flow structures with a high-speed video camera and measured CCFL (the relationship between superficial velocities of up-flow gas and down-flow liquid), pressure gradient dP/dz, and α in a RR vertical pipe with the diameter of 20 mm, and working fluids of air and water under flooding conditions, and we obtained fw and fi by using the annular flow model. The feature of flow structures in RR was occurrence of disturbance waves inside the vertical pipe, while they mainly appear at the bottom end in SR and RS. The liquid volume fraction (1-α), dimensionless pressure gradient -(dP/dz)*, and fi in RR for rough film were the same as those for rough film in SR and RS. (1-α), -(dP/dz)*, fw, and fi in RR for smooth film were close to those in SR for smooth film but they were larger than those in SR due to larger falling liquid volume fraction. The upward velocity of disturbance waves was also discussed.