Accelerating magnetic resonance fingerprinting (MRF) using t-blipped simultaneous multislice (SMS) acquisition
- 8 June 2015
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (5) , 2078-2085
Abstract
Purpose We incorporate simultaneous multislice (SMS) acquisition into MR fingerprinting (MRF) to accelerate the MRF acquisition. Methods The t‐Blipped SMS‐MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the signal from different simultaneously excited slices are encoded with different phases without disturbing the signal evolution. Furthermore, by varying the Gz blip area and/or polarity as a function of repetition time, the slices' differential phase can also be made to vary as a function of time. For reconstruction of t‐Blipped SMS‐MRF data, we demonstrate a combined slice‐direction SENSE and modified dictionary matching method. Results In Monte Carlo simulation, the parameter mapping from multiband factor (MB) = 2 t‐Blipped SMS‐MRF shows good accuracy and precision when compared with results from reference conventional MRF data with concordance correlation coefficients (CCC) of 0.96 for T1 estimates and 0.90 for T2 estimates. For in vivo experiments, T1 and T2 maps from MB=2 t‐Blipped SMS‐MRF have a high agreement with ones from conventional MRF. Conclusion The MB=2 t‐Blipped SMS‐MRF acquisition/reconstruction method has been demonstrated and validated to provide more rapid parameter mapping in the MRF framework. Magn Reson Med 75:2078–2085, 2016.Keywords
Funding Information
- NIH NIBIB (R01EB017219, R00EB012107, R01EB017337, P41EB015896)
- The National Key Basic Research Program of China (2013CB329501)
- The National Natural Science Foundation of China (81371518)
This publication has 21 references indexed in Scilit:
- Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penaltyMagnetic Resonance in Medicine, 2011
- Improvements in multislice parallel imaging using radial CAIPIRINHAMagnetic Resonance in Medicine, 2011
- Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion ImagingPLOS ONE, 2010
- Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRIMagnetic Resonance in Medicine, 2010
- Non‐Cartesian data reconstruction using GRAPPA operator gridding (GROG)Magnetic Resonance in Medicine, 2007
- On NUFFT-based gridding for non-Cartesian MRIJournal of Magnetic Resonance, 2007
- Parallel magnetic resonance imaging using the GRAPPA operator formalismMagnetic Resonance in Medicine, 2005
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- SIMAJournal of Computer Assisted Tomography, 1988