Abstract
This paper presents a hybrid intensity modulated radiation therapy (IMRT) optimization strategy which combines the speed of pencil beam (PB) and the accuracy of Monte Carlo (MC) dose calculations. After an initial deliverable‐based optimization using a PB algorithm, doses are recomputed using theMC code to determine dose correction factors, which are then utilized during further PB‐based optimization. The hybrid method is benchmarked with respect to full MC deliverable‐based optimization for ten prostate and ten head‐and‐neck IMRT plans. Final optimized plans are compared in terms of dose‐volume indices used for the plan optimization. Dose prediction errors (DPEs) and optimization convergence errors (OCEs) at intermediate steps of the hybrid sequence are evaluated. The hybrid method is found to produce optimized plans that are clinically equivalent to full MC‐based optimization, yet requires only 40% of the number of MC dose calculations. With the hybrid strategy presented here, MC‐based optimization results are achieved inor less on a modest computing cluster. While the initial PB‐deliverable‐based optimization is found to have DPEs and OCEs of up torelative to theprescription doses, application of the first MC correction reduces the average DPEs to less thanfor the prostate plans and less thanfor the head and neck plans. The maximum observed DPE or OCE isafter 1 MC dose correction, indicating that a single MC dose calculation correction might be sufficient for IMRT optimization.
Funding Information
  • National Institutes of Health (NIH-R01CA98524)

This publication has 50 references indexed in Scilit: