Early Clinical Outcomes of the Active Seal Technology of the AFX Endovascular Aortic Aneurysm System With the VELA Cuff for Patients With a Conical Proximal Neck
- 11 January 2022
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 30 (1) , 114-122
Abstract
Purpose: To evaluate the efficacy of the Active Seal technology employed in the AFX endovascular aortic aneurysm system (AFX), during endovascular aneurysm repair (EVAR) in patients with abdominal aortic aneurysms (AAAs) having a conical proximal neck. Materials and Methods: A retrospective analysis of the EVAR for AAA with a conical proximal neck using the AFX was performed at 17 Japanese hospitals between January 2016 and August 2020. The conical proximal neck was defined as a cone-shaped proximal neck, with more than 10% diameter increase within a 15 mm length at the proximal landing zone. All anatomical analyses were performed in the core laboratory, and cases with parallel walls within the proximal neck adequate for the landing zone were excluded from the study. Results: This study included 53 patients, but only 39 patients (mean age, 76.6 ± 6.7 years; 87.0% males; mean aneurysm diameter, 52.0 ± 8.0 mm) were analyzed after being characterized as having a pure conical neck by the core laboratory. The mean proximal neck diameters at the lower renal artery and proximal edge of the aneurysm were 20.0 ± 2.9 mm and 27.5 ± 4.9 mm, respectively. The mean proximal neck length was 21.5 ± 6.0 mm. Instructions for use violations other than the conical neck were observed in 15 patients (38.5%). The VELA cuff was used in all cases; however, additional proximal cuff was required in 9 more cases (23.1%). The Active Seal technology was able to significantly extend the proximal sealing zone from 21.5 ± 6.0 to 26.0 ± 12.2 mm ( p = .047). Thirty-six patients completed the 12-month follow-up (one patient was lost to follow-up, and 2 patients died from causes unrelated to the aneurysm), and there were no type-1a and 3 endoleaks with only one reintervention (2.6%) related to type 1b endoleak in the 12-month period. Furthermore, there was no significant enlargement of the proximal neck diameter at 12 months (at 1 month: 20.6 ± 3.4 mm and at 12 months: 21.3 ± 3.8 mm; p = .420). Conclusion: The Active Seal technology of the AFX significantly extended the proximal seal zone and no type-1a endoleak and proximal neck dilation was observed in patients with conical proximal neck at 12 months.Keywords
This publication has 25 references indexed in Scilit:
- Midterm Outcome of EndoAnchors for the Prevention of Endoleak and Stent-Graft Migration in Patients With Challenging Proximal Aortic Neck AnatomyJournal of Endovascular Therapy, 2015
- Active Proximal Sealing in the Endovascular Repair of Abdominal Aortic AneurysmsJournal of Endovascular Therapy, 2015
- Analysis of EndoAnchors for endovascular aneurysm repair by indications for useJournal of Vascular Surgery, 2014
- Clinical outcome of an extended proximal seal zone with the AFX endovascular aortic aneurysm systemJournal of Vascular Surgery, 2014
- Endovascular Repair of Abdominal Aortic Aneurysms With Reverse Taper Neck Anatomy Using the Endurant Stent-Graft: Analysis of Stent-Graft OversizingJournal of Endovascular Therapy, 2013
- Early Outcomes for Fenestrated and Chimney Endografts in the Treatment of Pararenal Aortic Pathologies Are Not Significantly Different: A Systematic Review With Pooled Data AnalysisJournal of Endovascular Therapy, 2012
- An evaluation of centerline of flow measurement techniques to assess migration after thoracic endovascular aneurysm repairJournal of Vascular Surgery, 2006
- Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: results from the zenith multicenter trialJournal of Vascular Surgery, 2004
- Intraoperative Proximal Endoleaks during AAA Stent-Graft Repair: Evaluation of Risk Factors and Treatment with Palmaz StentsJournal of Endovascular Therapy, 2001
- Anatomical Risk Factors for Proximal Perigraft Endoleak and Graft Migration Following Endovascular Repair of Abdominal Aortic AneurysmsEuropean Journal of Vascular and Endovascular Surgery, 2000