Joint Optimization of Collimator and Reconstruction Parameters in X-Ray Fluorescence Computed Tomography Using Analytical Point Spread Function and Model Observer
- 30 December 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (9) , 2443-2452
Abstract
Objective: To jointly optimize collimator design and image reconstruction algorithm in X-ray Fluorescence Computed Tomography (XFCT) for imaging low concentrations of high atomic number (Z) elements in small animal models. Methods: Single pinhole (SPH) collimator and three types of multi-pinhole (MPH) collimators were evaluated. MPH collimators with 5, 7, and 9 pinholes using lead, stainless steel and brass were considered. A digital cylindrical phantom (0.5 mm3 voxels) of 25 mm diameter and 25 mm height with a central 5 mm diameter and 12.5 mm height cylindrical insert containing gold nanoparticles (2:1 insert: background concentration) was modeled. A 125 kVp, 2 mm Sn filtered x-ray spectrum (0.5 cGy/projection) for gold K-shell XFCT was considered. System matrices were implemented using analytical point spread functions (PSF) for each pinhole collimator. Poisson noise was added to the projection data (16 equiangular views) before image reconstruction using Maximum-Likelihood Expectation-Maximization (ML-EM) algorithm. Signal-present and signal-absent images were generated for the detection task performed by a channelized Hotelling observer (CHO) with 10 Dense Difference-of-Gaussian channels. The area under the curve (AUC) in receiver operating characteristic was used as the image quality metric. Results: A stainless steel focusing type MPH with 7 pinholes and 20 iterations of ML-EM provided the highest AUC. Conclusion: MPH collimators outperformed SPH collimators for XFCT and consistently high AUCs were observed with focusing type MPH designs with 7 pinholes. Significance: The combinations of collimator design and image reconstruction parameters that maximized AUC were identified, which could improve the performance of XFCT.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering
- National Institutes of Health (R01 EB020658)
This publication has 52 references indexed in Scilit:
- Analytic Comparison Between X-Ray Fluorescence CT and K-Edge CTIEEE Transactions on Biomedical Engineering, 2013
- Experimental demonstration of benchtop x-ray fluorescence computed tomography (XFCT) of gold nanoparticle-loaded objects using lead- and tin-filtered polychromatic cone-beamsPhysics in Medicine & Biology, 2012
- Joint optimization of collimator and reconstruction parameters in SPECT imaging for lesion quantificationPhysics in Medicine & Biology, 2011
- The feasibility of polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects: a Monte Carlo studyPhysics in Medicine & Biology, 2011
- One-Shot Estimate of MRMC Variance: AUCAcademic Radiology, 2006
- Fully 3D Monte Carlo reconstruction in SPECT: a feasibility studyPhysics in Medicine & Biology, 2005
- Analytic determination of pinhole collimator sensitivity with penetrationIEEE Transactions on Medical Imaging, 2001
- Multireader receiver operating characteristic studies: A comparison of study designsAcademic Radiology, 1995
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- Addition of a channel mechanism to the ideal-observer modelJournal of the Optical Society of America A, 1987