AKAndrew Karellas

Andrew Karellas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrew Karellas has a total of 108 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development and performance evaluation of an upright dedicated cone‐beam breast CT system

    by Thomas C. Larsen, Hsin Wu Tseng, William Ross, Stephen Araujo, Pengwei Wu, Eri Haneda, Cynthia Davis, Andrew Karellas, Srinivasan Vedantham

    Background: Dedicated breast CT is an emerging breast X‐ray imaging modality. While current commercial breast CT systems use prone‐patient, pendant‐breast geometry, the system described here uses upright patient geometry with the uncompressed breast supported by a cup. Purpose: The purpose of this work is to describe the development of a newly designed, upright geometry, dedicated cone‐beam breast CT system and to evaluate its imaging performance using objective metrics. Methods: The prototype system uses a tungsten‐target, mammography‐format, X‐ray tube operating at 60 kV with 0.25 mm Cu and 1 mm Al added filtration, and a complementary metal‐oxide semiconductor (CMOS) detector with 0.152 mm pixel pitch coupled to 500 microns thick CsI:Tl scintillator. During short scan acquisition, the X‐ray source moves inferior to the breast, and 210 projections are acquired over an angular range of 210 degrees. The projections are reconstructed to an isotropic voxel pitch of 0.22 mm using Feldkamp‐Davis‐Kress (FDK) algorithm with Parker weights. Quantitative performance measures including linearity, modulation transfer function (MTF), and noise power spectrum (NPS) were evaluated. Phantom studies were conducted at various X‐ray tube current (mA) and pulse‐width (ms) combinations with the objective of determining the minimum detectable size of low‐contrast targets and calcium carbonate spheres representing soft tissue lesions and microcalcification clusters, respectively. Results: The measured 1st HVL was 4.23 ± 0.01 mm of Al. The limiting resolution (10% MTF) was 2.18 mm −1 in the coronal (cross‐sectional) plane near the axis of rotation. In the coronal plane, the peak of the NPS occurred at 0.5 mm −1 . Phantom studies at a mean glandular dose of 3–5.7 mGy showed the ability to visualize 2–3 mm low‐contrast targets and 0.27–0.29 mm calcium carbonate spheres. Conclusions: The developed upright breast CT system showed the ability to achieve high spatial resolution and low contrast resolution. The excellent technical performance of the breast CT system reported here suggests that further investigations using patient imaging are warranted.

  • Maximizing microcalcification detectability in low-dose dedicated cone-beam breast CT: parallel cascades-based theoretical analysis

    by Thomas Larsen, Hsin Wu Tseng, Rachawadee Trinate, Zhiyang Fu, Jing-Tzyh Alan Chiang, Andrew Karellas, Srinivasan Vedantham

    PurposeWe aim to determine the combination of X-ray spectrum and detector scintillator thickness that maximizes the detectability of microcalcification clusters in dedicated cone-beam breast CT.ApproachA cascaded linear system analysis was implemented in the spatial frequency domain and was used to determine the detectability index using numerical observers for the imaging task of detecting a microcalcification cluster with 0.17 mm diameter calcium carbonate spheres. The analysis considered a thallium-doped cesium iodide scintillator coupled to a complementary metal-oxide semiconductor detector and an analytical filtered-back-projection reconstruction algorithm. Independent system parameters considered were the scintillator thickness, applied X-ray tube voltage, and X-ray beam filtration. The combination of these parameters that maximized the detectability index was considered optimal.ResultsPrewhitening, nonprewhitening, and nonprewhitening with eye filter numerical observers indicate that the combination of 0.525 to 0.6 mm thick scintillator, 70 kV, and 0.25 to 0.4 mm added copper filtration maximized the detectability index at a mean glandular dose (MGD) of 4.5 mGy.ConclusionUsing parallel cascade systems’ analysis, the combination of parameters that could maximize the detection of microcalcifications was identified. The analysis indicates that a harder beam than that used in current practice may be beneficial for the task of detecting microcalcifications at an MGD suitable for breast cancer screening.


  • Cone-beam breast CT using an offset detector: effect of detector offset and image reconstruction algorithm

    by Hsin Wu Tseng, Andrew Karellas, Srinivasan Vedantham

    Objective. A dedicated cone-beam breast computed tomography (BCT) using a high-resolution, low-noise detector operating in offset-detector geometry has been developed. This study investigates the effects of varying detector offsets and image reconstruction algorithms to determine the appropriate combination of detector offset and reconstruction algorithm. Approach. Projection datasets (300 projections in 360°) of 30 breasts containing calcified lesions that were acquired using a prototype cone-beam BCT system comprising a 40 × 30 cm flat-panel detector with 1024 × 768 detector pixels were reconstructed using Feldkamp–Davis–Kress (FDK) algorithm and served as the reference. The projection datasets were retrospectively truncated to emulate cone-beam datasets with sinograms of 768 × 768 and 640 × 768 detector pixels, corresponding to 5 cm and 7.5 cm lateral offsets, respectively. These datasets were reconstructed using the FDK algorithm with appropriate weights and an ASD-POCS-based Fast, total variation-Regularized, Iterative, Statistical reconstruction Technique (FRIST), resulting in a total of 4 offset-detector reconstructions (2 detector offsets × 2 reconstruction methods). Signal difference-to-noise ratio (SDNR), variance, and full-width at half-maximum (FWHM) of calcifications in two orthogonal directions were determined from all reconstructions. All quantitative measurements were performed on images in units of linear attenuation coefficient (1/cm). Results. The FWHM of calcifications did not differ ( P > 0.262) among reconstruction algorithms and detector formats, implying comparable spatial resolution. For a chosen detector offset, the FRIST algorithm outperformed FDK in terms of variance and SDNR ( P < 0.0001). For a given reconstruction method, the 5 cm offset provided better results. Significance. This study indicates the feasibility of using the compressed sensing-based, FRIST algorithm to reconstruct sinograms from offset-detectors. Among the reconstruction methods and detector offsets studied, FRIST reconstructions corresponding to a 30 cm × 30 cm with 5 cm lateral offset, achieved the best performance. A clinical prototype using such an offset geometry has been developed and installed for clinical trials.


  • Sparse-view, short-scan, dedicated cone-beam breast computed tomography: image quality assessment

    by Hsin Wu Tseng, Andrew Karellas, Srinivasan Vedantham

    The purpose of this study is to quantify the impact of sparse-view acquisition in short-scan trajectories, compared to 360-degrees full-scan acquisition, on image quality measures in dedicated cone-beam breast computed tomography (BCT). Projection data from 30 full-scan (360-degrees; 300 views) BCT exams with calcified lesions were selected from an existing clinical research database. Feldkamp-Davis-Kress (FDK) reconstruction of the full-scan data served as the reference. Projection data corresponding to two short-scan trajectories, 204 and 270-degrees, which correspond to the minimum and maximum angular range achievable in a cone-beam BCT system were selected. Projection data were retrospectively sampled to provide 225, 180, and 168 views for 270-degrees short-scan, and 170 views for 204-degrees short-scan. Short-scans with 180 and 168 views in 270-degrees used non-uniform angular sampling. A fast, iterative, total variation-regularized, statistical reconstruction technique (FIRST) was used for short-scan image reconstruction. Image quality was quantified by variance, signal-difference to noise ratio (SDNR) between adipose and fibroglandular tissues, full-width at half-maximum (FWHM) of calcifications in two orthogonal directions, as well as, bias and root-mean-squared-error (RMSE) computed with respect to the reference full-scan FDK reconstruction. The median values of bias (8.6 × 10 −4 –10.3 × 10 −4 cm −1 ) and RMSE (6.8 × 10 −6 –9.8 × 10 −6 cm −1 ) in the short-scan reconstructions, computed with the full-scan FDK as the reference were close to, but not zero (P < 0.0001, one-sample median test). The FWHM of the calcifications in the short-scan reconstructions did not differ significantly from the reference FDK reconstruction (P > 0.118), except along the superior-inferior direction for the short-scan reconstruction with 168 views in 270-degrees (P = 0.046). The variance and SDNR from short-scan reconstructions were significantly improved compared to the full-scan FDK reconstruction (P < 0.0001). This study demonstrates the feasibility of the short-scan, sparse-view, compressed sensing-based iterative reconstruction. This study indicates that shorter scan times and reduced radiation dose without sacrificing image quality are potentially feasible.


  • Joint Optimization of Collimator and Reconstruction Parameters in X-Ray Fluorescence Computed Tomography Using Analytical Point Spread Function and Model Observer

    by Hsin Wu Tseng, Srinivasan Vedantham, Sang Hyun Cho, Andrew Karellas

    Objective: To jointly optimize collimator design and image reconstruction algorithm in X-ray Fluorescence Computed Tomography (XFCT) for imaging low concentrations of high atomic number (Z) elements in small animal models. Methods: Single pinhole (SPH) collimator and three types of multi-pinhole (MPH) collimators were evaluated. MPH collimators with 5, 7, and 9 pinholes using lead, stainless steel and brass were considered. A digital cylindrical phantom (0.5 mm3 voxels) of 25 mm diameter and 25 mm height with a central 5 mm diameter and 12.5 mm height cylindrical insert containing gold nanoparticles (2:1 insert: background concentration) was modeled. A 125 kVp, 2 mm Sn filtered x-ray spectrum (0.5 cGy/projection) for gold K-shell XFCT was considered. System matrices were implemented using analytical point spread functions (PSF) for each pinhole collimator. Poisson noise was added to the projection data (16 equiangular views) before image reconstruction using Maximum-Likelihood Expectation-Maximization (ML-EM) algorithm. Signal-present and signal-absent images were generated for the detection task performed by a channelized Hotelling observer (CHO) with 10 Dense Difference-of-Gaussian channels. The area under the curve (AUC) in receiver operating characteristic was used as the image quality metric. Results: A stainless steel focusing type MPH with 7 pinholes and 20 iterations of ML-EM provided the highest AUC. Conclusion: MPH collimators outperformed SPH collimators for XFCT and consistently high AUCs were observed with focusing type MPH designs with 7 pinholes. Significance: The combinations of collimator design and image reconstruction parameters that maximized AUC were identified, which could improve the performance of XFCT.


  • Open Access

    Reduced Patient Radiation Exposure during Neurodiagnostic and Interventional X-Ray Angiography with a New Imaging Platform

    by K. van der Marel, S. Vedantham, I.M.J. van der Bom, M. Howk, T. Narain, K. Ty, A. Karellas, M.J. Gounis, A.S. Puri, A.K. Wakhloo

    BACKGROUND AND PURPOSE: Advancements in medical device and imaging technology as well as accruing clinical evidence have accelerated the growth of the endovascular treatment of cerebrovascular diseases. However, the augmented role of these procedures raises concerns about the radiation dose to patients and operators. We evaluated patient doses from an x-ray imaging platform with radiation dose–reduction technology, which combined image noise reduction, motion correction, and contrast-dependent temporal averaging with optimized x-ray exposure settings. MATERIALS AND METHODS: In this single-center, retrospective study, cumulative dose-area product inclusive of fluoroscopy, angiography, and 3D acquisitions for all neurovascular procedures performed during a 2-year period on the dose-reduction platform were compared with a reference platform. Key study features were the following: The neurointerventional radiologist could select the targeted dose reduction for each patient with the dose-reduction platform, and the statistical analyses included patient characteristics and the neurointerventional radiologist as covariates. The analyzed outcome measures were cumulative dose (kerma)-area product, fluoroscopy duration, and administered contrast volume. RESULTS: A total of 1238 neurointerventional cases were included, of which 914 and 324 were performed on the reference and dose-reduction platforms, respectively. Over all diagnostic and neurointerventional procedures, the cumulative dose-area product was significantly reduced by 53.2% (mean reduction, 160.3 Gy × cm2; P < .0001), fluoroscopy duration was marginally significantly increased (mean increase, 5.2 minutes; P = .0491), and contrast volume was nonsignificantly increased (mean increase, 15.3 mL; P = .1616) with the dose-reduction platform. CONCLUSIONS: A significant reduction in patient radiation dose is achievable during neurovascular procedures by using dose-reduction technology with a minimal impact on workflow.


  • SU-E-CAMPUS-I-01: Nanometric Organic Photovoltaic Thin Film X-Ray Detectors for Clinical KVp Beams

    by Bassem Elshahat, Ilya Filipyev, Suman Shrestha, Jurgen Hesser, Hardeep Gill, Jayant Kumar, Andrew Karellas, Piotr Zygmanski, Erno Sajo

  • Open Access

    Dedicated breast CT: geometric design considerations to maximize posterior breast coverage

    by Srinivasan Vedantham, Andrew Karellas, Margaret M Emmons, Lawrence J Moss, Sarwat Hussain, Stephen P Baker

    An Institutional Review Board-approved protocol was used to quantify breast tissue inclusion in 52 women, under conditions simulating both craniocaudal (CC) and mediolateral oblique (MLO) views in mammography, dedicated breast CT in the upright subject position, and dedicated breast CT in the prone subject position. Using skin as a surrogate for the underlying breast tissue, the posterior aspect of the breast that is aligned with the chest-wall edge of the breast support in a screen-film mammography system was marked with the study participants positioned for CC and MLO views. The union of skin marks with the study participants positioned for CC and MLO views was considered to represent chest-wall tissue available for imaging with mammography and served as the reference standard. For breast CT, a prone stereotactic breast biopsy unit and a custom-fabricated barrier were used to simulate conditions during prone and upright breast CT, respectively. For the same breast marked on the mammography system, skin marks were made along the breast periphery that was just anterior to the apertures of the prone biopsy unit and the upright barrier. The differences in skin marks between subject positioning simulating breast CT (prone, upright) and mammography were quantified at six anatomic locations. For each location, at least one study participant had a skin mark from breast CT (prone, upright) posterior to mammography. However for all study participants, there was at least one anatomic location where the skin mark from mammography was posterior to that from breast CT (prone, upright) positioning. The maximum amount by which the skin mark from mammography was posterior to breast CT (prone and upright) over all six locations was quantified for each study participant and pair-wise comparison did not exhibit statistically significant difference between prone and upright breast CT (paired t- test, p = 0.4). Quantitatively, for 95% of the study participants the skin mark from mammography was posterior to breast CT (prone or upright) by at the most 9 mm over all six locations. Based on the study observations, geometric design considerations targeting chest-wall coverage with breast CT equivalent to mammography, wherein part of the x-ray beam images through the swale during breast CT are provided. Assuming subjects can extend their chest in to a swale, the optimal swale-depth required to achieve equivalent coverage with breast CT images as mammograms for 95% of the subjects varies in the range of ~30-50 mm for clinical prototypes and was dependent on the system geometry.