Design and Characterisation of Tissue-Mimicking Gel Phantoms for Diffusion Kurtosis Imaging
Authors:
Preprint
Abstract
The purpose of the study was to create tissue-mimicking gel phantoms appropriate for diffusion kurtosis imaging (DKI). Diffusion coefficients, including the well-known apparent diffusion coefficients (ADCs) and the diffusion coefficient based on the kurtosis model for the decay of the diffusion signal and (excess) kurtosis values were experimentally determined for the gelling agents of agar, agarose and polyvinyl alcohol (PVA) cryogel commonly used in multi-modal imaging. Although we observe an increase in kurtosis with the concentration of the gelling agents, the values obtained from diffusion-weighted magnetic resonance imaging (DW-MRI) were too low (under the expectations) to mimic the range of values reported in the literature for various healthy and diseased tissues. To create tissue-mimicking gels phantoms with more realistic kurtosis values, different concentrations of glass microbeads were added. Experimental characterisation showed that realistic kurtosis values for a range of tissues may be obtained by varying the concentration of the gelling agents and glass microbeads appropriately. To assess the effect of adding glass microbeads on other key properties such as relaxation times, saturation recovery and multi spin-echo relaxometry experiments were performed on all gel phantoms. The gel phantoms were also examined using computed tomography (CT) to evaluate their homogeneity and to observe the effect of glass microbeads on the CT numbers of the phantoms.Keywords
All Related Versions
This publication has 28 references indexed in Scilit:
- Characterisation of Elastic and Acoustic Properties of an Agar-Based Tissue Mimicking MaterialAnnals of Biomedical Engineering, 2015
- Mathematical models for diffusion‐weighted imaging of prostate cancer using b values up to 2000 s/mm2: Correlation with Gleason score and repeatability of region of interest analysisMagnetic Resonance in Medicine, 2014
- Evaluation of different mathematical models for diffusion-weighted imaging of normal prostate and prostate cancer using high b-values: A repeatability studyMagnetic Resonance in Medicine, 2014
- Diffusion-weighted signal models in healthy and cancerous peripheral prostate tissues: Comparison of outcomes obtained at different b-valuesJournal of Magnetic Resonance Imaging, 2013
- Intravoxel incoherent motion MR imaging for prostate cancer: An evaluation of perfusion fraction and diffusion coefficient derived from different b‐value combinationsMagnetic Resonance in Medicine, 2012
- Microscopic diffusion anisotropy in formalin fixed prostate tissue: Preliminary findingsMagnetic Resonance in Medicine, 2012
- Magnetic resonance diffusion characteristics of histologically defined prostate cancer in humansMagnetic Resonance in Medicine, 2009
- Diffusional kurtosis imaging: The quantification of non‐gaussian water diffusion by means of magnetic resonance imagingMagnetic Resonance in Medicine, 2005
- A Phantom for diffusion‐weighted imaging of acute strokeJournal of Magnetic Resonance Imaging, 1998
- Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imagingMagnetic Resonance in Medicine, 1990