Computer‐Aided Design Evaluation of Harvestable Mandibular Bone Volume: A Clinical and Tomographic Human Study
- 15 November 2012
- journal article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 16 (3) , 348-355
Abstract
Purpose: To evaluate and compare the volume of bone graft material that can be safely harvested from the mandibular symphysis and rami using a computer‐aided design (CAD) software program.Materials and Methods: Preoperative computerized tomography scans from 40 patients undergoing bone augmentation procedures were analyzed. Symphysis and rami cross sections were mapped using a CAD software program (AutoCAD®, Autodesk, Inc., San Rafael, CA, USA) to evaluate the bone volume that can be safely harvested. CAD calculations were contrasted to intrasurgical measurements in a subgroup of 20 individuals.Results: CAD calculations yielded a safe harvestable osseous volume of 1.44 cm3 ± 0.49 for the symphysis and 0.82 cm3 ± 0.21 for each ramus (p < .0001, confidence interval [CI] 95%: 0.47–0.78). These measurements were significantly lower (p < .0001) than the bone volumes harvested intrasurgically for both symphysis and ramus, respectively (2.40 cm3 ± 0.50 vs. 2.65 cm3 ± 0.45). CAD calculations of harvestable symphysis and ramus bone translated into an average of 2.40 cm3 ± 0.50 (range: 1.80–3.10 cm3) and 2.65 cm3 ± 0.45 (range: 1.90–3.50) of particulate bone graft intrasurgically, respectively. Ramus cortical was significantly thicker than the symphysis cortical, 2.9 ± 0.4 mm versus 2.19 mm ± 0.4 mm (p < .0001, CI 95%: 0.45–1.03).Conclusion: The symphysis and rami are good harvesting sources to obtain dense corticocancellous bone. The significant volumetric CAD differences between the symphysis and ramus seem to balance out intrasurgically and may be due to the greater cortical bone volume at the ramus area. It is plausible to harvest an average of 7.70 cm3 from the symphysis and rami alone. The use of a CAD software program can enhance surgical treatment planning prior to bone transplantation.Keywords
This publication has 25 references indexed in Scilit:
- Cone-beam computerized tomography imaging and analysis of the upper airway: a systematic review of the literatureInternational Journal of Oral and Maxillofacial Surgery, 2011
- A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensionsDentomaxillofacial Radiology, 2011
- Quantitation of Mandibular Symphysis Volume as a Source of Bone GraftingClinical Implant Dentistry and Related Research, 2010
- Human Bone Repair After Mandibular Symphysis Block Harvesting: A Clinical and Tomographic StudyJournal of Periodontology, 2010
- Quantitation of Mandibular Ramus Volume as a Source of Bone GraftingClinical Implant Dentistry and Related Research, 2009
- Morbidity after Chin Bone Harvesting – A Retrospective Long‐Term Follow‐Up StudyClinical Implant Dentistry and Related Research, 2009
- Periodontal Biotype Influence on the Volume Maintenance of Onlay GraftsJournal of Periodontology, 2009
- Variation in the apparent density of human mandibular bone with age and dental statusJournal of Anatomy, 1998
- Composite grafting of the maxillary sinus for placement of endosteal implants. A preliminary report of 48 patientsInternational Journal of Oral and Maxillofacial Surgery, 1992
- Comparison of bone formed intramuscularly after transplantation of scapular and calvarial osteoblastsBone, 1988