Experimental Investigation of the Effect of Conductor Temperature on Corona Performance in Overhead Transmission Lines
Open Access
- 29 August 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 122114-122125
Abstract
The maximum conductor temperature regulates the maximum amount of power that overhead lines can transmit. If this maximum temperature is exceeded, excessive line sag and accelerated conductor aging may occur. This is particularly true for the most popular steel-reinforced conductors or aluminium anneal, in which high temperatures can cause grease, which is used to prevent corrosion from seeping. Hightemperature low-sag conductors have been developed to increase current carrying capacity. In addition to the temperature constraint, overhead transmission lines largely depend on the corona discharge performance. This paper presents experimental results on the investigation of corona performance due to conductor temperature. An experimental configuration that uses a 10 kVA power transformer in cascade with a 10 kVA high current low voltage transformer both connected to the conductor in the corona cage was successfully developed. This configuration allows for heating the conductor while connected to the high voltage and allows for measuring corona current using the screened electrode method of corona cage. The results indicate an increase in corona current with rising conductor temperature, accompanied by a 25% to 32% decrease in inception voltage. The primary factors contributing to these trends were identified as relative air density and the Townsend coefficient. A temperature model incorporating the ionization region was developed to calculate the relative air density accurately. Additionally, To account for the effect of conductor temperature, the well-known surface inception field strength formula proposed by Peek was refined through optimization. Comparisons between the refined Peek’s formula and the measured results demonstrated successful alignment. This research enhances our understanding of corona performance with conductor temperature, providing valuable insights for optimizing transmission line design and operation.Keywords
Funding Information
- Eskom Tertiary Education Support Programme (TESP) and Eskom EPEP, both of which are research programs at the University of KwaZulu-Natal
This publication has 27 references indexed in Scilit:
- Characteristics of negative DC discharge in a wire–cylinder configuration under coal pyrolysis gas components at high temperaturesRSC Advances, 2018
- Revisiting the positive DC corona discharge theory: Beyond Peek's and Townsend's lawPhysics of Plasmas, 2018
- Numerical simulation of Trichel pulses of negative DC corona discharge based on a plasma chemical modelJournal of Physics D: Applied Physics, 2017
- Comparative study of two different measuring methods for corona current pulsesJournal of Electrostatics, 2017
- Current-voltage characteristics of dc corona discharges in air between coaxial cylindersPhysics of Plasmas, 2015
- Characteristics of negative DC corona discharge in a wire–plate configuration at high temperaturesSeparation and Purification Technology, 2015
- Ozone generation by negative direct current corona discharges in dry air fed coaxial wire-cylinder reactorsJournal of Applied Physics, 2013
- Effects of temperature and pressure change on positive corona and sparkover under direct voltage in short airgapsIET Science, Measurement & Technology, 2007
- Corona-induced pressures, potentials, fields and currents in electrostatic precipitator configurationsJournal of Physics D: Applied Physics, 2007
- Positive corona inception in air at elevated temperaturesIEE Proceedings - Science, Measurement and Technology, 2006