Diagnostic performance of percutaneous lung biopsy using automated biopsy needles under CT-fluoroscopic guidance for ground-glass opacity lesions

Authors:
  • RYR Yoshimatsu
    R Yoshimatsu
  • HMH Miura
    H Miura
  • KYK Yamada
    K Yamada
  • ATA Takahata
    A Takahata
  • TMT Matsumoto
    T Matsumoto
  • THT Hasebe
    T Hasebe

Abstract
Objective:The goal of our study was to evaluate the diagnostic performance of percutaneous lung biopsy under CT-fluoroscopic guidance for ground-glass opacity (GGO) lesions.Methods:85 percutaneous needle lung biopsies were performed in 73 patients. Specimens were obtained by core biopsy utilising an automated cutting needle and were evaluated histologically. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up.Results:Rates of adequate specimens obtained and of precise diagnosis by needle biopsy were 92.9% (79/85) and 90.6% (77/85) of evaluated lung lesions, respectively. Precise diagnosis was achieved in 87.1% (27/31) of lesions ≤10 mm in diameter, 90.0% (36/40) of lesions >10 mm to ≤20 mm and 100.0% (14/14) of lesions >20 mm. Precision in diagnosing GGO lesions according to the GGO component was 73.9% (17/23) for pure GGO lesions and 96.8% (60/62) for part-solid GGO lesions. Obtaining a precise diagnosis did not differ significantly according...

This publication has 50 references indexed in Scilit: