Precorneal Residence Time of Artificial Tears Measured in Dry Eye Subjects
Authors:
- 1 August 2008
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 85 (8) , 725-731
Abstract
Purpose.: The purpose of this investigation was to measure the precorneal residence time of saline and five marketed artificial tears in dry eye subjects using fluorometry. Methods.: FITC‐dextran, 70 kDa molecular weight, was admixed under sterile conditions (0.1% wt/vol) into buffered saline and the marketed artificial tear formulations of varying viscosity. Precorneal residence time (RT) was measured directly in 16 mild to moderate dry eye subjects, classified by sub‐type, in a six‐way cross‐over, masked and randomized study. FITC‐dextran tracer decay with a scanning fluorometer was used to estimate the gross RT (i.e., the time in minutes for the signal to return to baseline). Results.: All subjects were classified as having non‐inflammatory meibomian gland dysfunction except one, who had a mixture of aqueous deficiency and meibomian gland dysfunction. In two separate determinations, the saline RTs were 19.1 ± 7.4 and 17.6 ± 8.2 min. The RTs for the formulations varied to some degree by viscosity, with two higher viscosity formulations demonstrating the longest RTs of 36 to 41 min, approximately twice that of saline (p < 0.001 for both 0.4% polyethylene glycol/0.3% propylene glycol, and 1.0% carboxymethylcellulose). An oil emulsion, low viscosity carboxymethylcellulose and moderate viscosity hydroxypropylmethylcellulose‐containing formulation were not statistically different from saline (RTs of 18, 22 and 24 min, p values = 0.983, 0.818 and 0.099, respectively). Conclusions.: More than two‐fold RT differences were found for the higher viscosity, more muco‐adhesive formulations compared to saline. However, other formulations provided RTs close to saline, suggesting that RT is influenced by factors other than simple viscosity. Future studies should examine the interplay of spreading characteristics, pseudoplasticity and muco‐adhesion relative to RT to determine the individual and cumulative effects on formulation retention.Keywords
This publication has 16 references indexed in Scilit:
- A Pre‐application Drop Containing Carboxymethylcellulose Can Reduce Multipurpose Solution‐Induced Corneal StainingOptometry and Vision Science, 2007
- A standardized visual scale for evaluation of tear fluorescein clearanceOphthalmology, 2000
- Ocular Surface Residence Times of Artificial Tear SolutionsCornea, 1992
- A comparison of the precorneal residence of an artificial tear preparation in patients with keratoconjunctivitis sicca and normal volunteer subjects using gamma scintigraphyActa Ophthalmologica, 1991
- Prevalence of Meibomian Gland DysfunctionOptometry and Vision Science, 1990
- Precorneal residence times of sodium hyaluronate solutions studied by quantitative gamma scintigraphyEye, 1990
- The evaluation of viscous ophthalmic vehicles by slit lamp fluorophotometry in humansInternational Journal of Pharmaceutics, 1989
- Fluorophotometric measurements of tear turnover rate in normal healthy persons: Evidence for a circadian rhythmEye, 1987
- Meibomian orifices and Marx's line Studied by Triple Vital StainingActa Ophthalmologica, 1985
- The questionably dry eye.British Journal of Ophthalmology, 1981