JPJerry R. Paugh

Jerry R. Paugh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jerry R. Paugh has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Preliminary Study of Silicone Hydrogel Lens Material and Care Solution Bioincompatibilities

    by Jerry R Paugh, Andrew Loc Nguyen, Jonathan Q Hall, Daniel Krall, Justin R Webb, Alison C Ramsey, David L Meadows

    The study purpose was to evaluate corneal barrier function and staining relative to potential bioincompatibilities. This was a randomized double-masked study (n = 25 subjects). Three lens material-care solution combinations were tested: (1) lotrafilcon B/polyhexamethylene biguanide (PHMB)-based multipurpose (MPS) solution (MPS-1); (2) lotrafilcon B/polyquaternium-1 and myristamidopropyl dimethylamine-based solution (MPS-2); and (3) lotrafilcon B and another PHMB-based solution (MPS-3). Saline served as the control. New lenses were soaked in the preserved solutions or saline and then worn for 2 hours before corneal measurements. Barrier function was characterized by the fluorescein penetration rate, corneal amount, both measured with an objective scanning fluorometer. The dye penetration rate ratio, test to control; amount ratio, test to control, and corneal staining were evaluated. The mean rate ratios (± SD) for the combinations were 2.98 (± 3.04), 1.23 (± 1.01), and 1.83 (± 1.77) for MPS-1, MPS-2, and MPS-3 solutions, respectively. Significant ratio differences were found across regimens (P = 0.007); for MPS-1 compared with baseline (P = 0.031) and for MPS-1 compared with MPS-2 (P = 0.007). The statistical results for staining were similar. Use of an objective quantitative physiological method suggests that significant differences in lens solution bioincompatibilities occur that mirror corneal staining data relative to corneal compromise.


  • Retention and Retention of Effect of Topical Formulations in Dry Eye Subjects

    by Jerry R. Paugh, Andrew Loc Nguyen, Pochi Huang, Julie S. Hwang

    Purpose.: It was the purpose of this investigation to examine both retention time (RT) and retention of effect of two ophthalmic formulations in the same dry eye subjects. Methods.: This was a randomized, subject‐masked cross‐over study. Dry eye subjects, characterized by sub‐type, were recruited. For direct RT measurement, fluorescein isothiocyanate (FITC)‐dextran, 70 kDa molecular weight, was admixed at 0.1% wt/vol concentration into buffered saline (active control) and a viscous marketed artificial tear formulations (test formulation). RT in minutes was estimated directly as the return to baseline intrinsic fluorescence with an objective scanning fluorometer. Retention of effect was measured with a xeroscope as non‐invasive breakup time (NIBUT) and by use of a numerical rating scale for comfort. Results.: Eleven subjects, with most being classified as having non‐inflammatory meibomian gland dysfunction, completed the study. The RTs averaged 17.7 (±10.0) and 26.8 (±16.5) minutes for the saline and test formulations, respectively. The averages for NIBUT were 8.73 (±6.1) and 19.5 (±4.9) minutes, for saline and the test formulations, respectively. Return to baseline for the numerical rating scale comfort averages were 9.91 (±4.1) and 20.21 (±6.4) minutes for the saline and test formulations, respectively. When residence time was subtracted from the retention of effect measures, no statistical significance was found for the polymeric solution (vs. comfort, p = 0.153; vs. NIBUT, p = 0.109). However, statistical differences were found for direct retention compared against comfort (p = 0.01) and NIBUT (p = 0.004) for buffered saline. Conclusions.: It seems that these two retention of effect measures are much shorter than RT measured directly. Future work should aim to confirm these findings in additional dry eye sub‐types and in those with more severe disease manifestations.


  • Precorneal Residence Time of Artificial Tears Measured in Dry Eye Subjects

    by Jerry R. Paugh, Andrew Loc Nguyen, Howard A. Ketelson, Mike T. Christensen, David L. Meadows

    Purpose.: The purpose of this investigation was to measure the precorneal residence time of saline and five marketed artificial tears in dry eye subjects using fluorometry. Methods.: FITC‐dextran, 70 kDa molecular weight, was admixed under sterile conditions (0.1% wt/vol) into buffered saline and the marketed artificial tear formulations of varying viscosity. Precorneal residence time (RT) was measured directly in 16 mild to moderate dry eye subjects, classified by sub‐type, in a six‐way cross‐over, masked and randomized study. FITC‐dextran tracer decay with a scanning fluorometer was used to estimate the gross RT (i.e., the time in minutes for the signal to return to baseline). Results.: All subjects were classified as having non‐inflammatory meibomian gland dysfunction except one, who had a mixture of aqueous deficiency and meibomian gland dysfunction. In two separate determinations, the saline RTs were 19.1 ± 7.4 and 17.6 ± 8.2 min. The RTs for the formulations varied to some degree by viscosity, with two higher viscosity formulations demonstrating the longest RTs of 36 to 41 min, approximately twice that of saline (p < 0.001 for both 0.4% polyethylene glycol/0.3% propylene glycol, and 1.0% carboxymethylcellulose). An oil emulsion, low viscosity carboxymethylcellulose and moderate viscosity hydroxypropylmethylcellulose‐containing formulation were not statistically different from saline (RTs of 18, 22 and 24 min, p values = 0.983, 0.818 and 0.099, respectively). Conclusions.: More than two‐fold RT differences were found for the higher viscosity, more muco‐adhesive formulations compared to saline. However, other formulations provided RTs close to saline, suggesting that RT is influenced by factors other than simple viscosity. Future studies should examine the interplay of spreading characteristics, pseudoplasticity and muco‐adhesion relative to RT to determine the individual and cumulative effects on formulation retention.


  • Poster 16: Clinical and Epithelial Barrier Evidence of Silicone Hydrogel and Care Solution Bio-Incompatibilities

    by Alison C. Ramsey, David L. Meadows, Jerry R. Paugh, Jonathan Q. Hall, Maryn C. Peinovich, Andrew L. Nguyen

  • A Pre‐application Drop Containing Carboxymethylcellulose Can Reduce Multipurpose Solution‐Induced Corneal Staining

    by Jerry R. Paugh, Harue J. Marsden, Timothy B. Edrington, Paul N. Deland, Peter A. Simmons, Joseph G. Vehige

    Purpose.: Use of polyhexanide based multipurpose solutions (MPSs) for contact lens disinfection has been linked to low‐grade corneal staining. In vitro data suggest that carboxymethylcellulose (CMC) may neutralize polyhexanides. The purpose of this investigation was to determine whether a pre‐application drop of CMC reduces polyhexanide staining in vivo . Methods.: Thirty adapted soft contact lens (SCL) wearers participated in this investigator‐masked, randomized, two‐way cross‐over study. Subjects wore a new Group II lens (alphafilcon A, 66% water) daily for 4 weeks and disinfected lenses using a MPS containing 0.0001% polyaminopropyl biguanide. A lens lubricant containing either CMC or povidone as the primary viscolyzer was applied to the lens each day before lens wear. Biomicroscopic signs and symptomatology were assessed. The difference in scores, 0 to 4 weeks and the difference between lubricants were analyzed. Results.: The cumulative fluorescein staining scores for combined eyes demonstrated a significant increase over time (e.g., cumulative staining score; p = 0.004 and p < 0.001 for CMC and povidone, respectively, matched pairs t‐test, two‐tailed), suggesting that for both lubricants the staining worsened with wear. This effect was expected and likely driven by the MPS. However, the mean cumulative staining scores for CMC and povidone were 2.8 and 2.6 out of 20 possible at baseline, increasing to 4.9 and 7.1 at 4 weeks, respectively. The increases were significantly different (p = 0.003, matched pairs t‐test, two‐tailed) suggesting a greater increase in corneal staining for the povidone lubricant. The symptom scores were not significantly different, 0 to 4 weeks by regimen or between preinstillation drops. Conclusions.: These results suggest that a CMC‐containing preapplication drop can reduce corneal staining resulting from disinfection with a polyhexanide MPS. This result is consistent with a proposed mechanism for CMC to neutralize cationic disinfectants and may offer clinicians another means to reduce this type of corneal staining.


    • 1 April 2002
      • Vol. 43  (4) , 1032-9

    A novel method to evaluate residence time in humans using a nonpenetrating fluorescent tracer.

    by David L Meadows, Jerry R Paugh, Abhay Joshi, Julie Mordaunt

    The purpose of these investigations was to develop an improved method for measuring precorneal residence time (RT) and to demonstrate its efficacy with novel formulations. A biomicroscope was adapted for use as a clinical fluorometer. Using a nonpenetrating fluorescent probe (FITC-dextran, 70,000-73,000 molecular weight [MW]), RT was estimated as the time to return to baseline (gross RT) and from parameters derived from least-squares regression fits to the decay data (area under the curve [AUC], elimination rate, and time for 50% of the signal to be eliminated [T(50)]). One rabbit and two human studies were conducted. The studies were randomized, double-masked, and controlled. Repeatability in humans was examined in 15 subjects (six determinations per subject, n = 90 total). The FITC-dextran tracer did not penetrate into corneal tissue. The rabbit gross RTs were 14.5, 15.0, and 16.0 minutes for three low-viscosity solutions (eta = 2.7-7.7 mPa/sec) and 22.5 minutes for a more viscous solution (eta = 357 mPa/sec). For a high-viscosity (eta approximately equal 30,000 mPa/sec) gel in humans, the method demonstrated approximately a twofold increase in gross RT and AUC compared with buffered saline. Repeatability of the method appeared acceptable, with intersubject variability the most significant factor affecting precision. The new method is safe and convenient and offers comprehensive RT data. Furthermore, it appears to differentiate among formulations. However, as with other tear-influenced parameters, there is significant variability. Thus, sufficient sample sizes are necessary for meaningful comparative investigations.